Literature DB >> 19099304

The influence of the centre of rotation on implant survival using a modular stem hip prosthesis.

Francesco Traina1, Marcello De Fine, Federico Biondi, Enrico Tassinari, Andrea Galvani, Aldo Toni.   

Abstract

The restoration of the hip centre of rotation in an anatomical position is considered to be relevant for total hip prosthesis survival. When the cup is implanted with a high centre of rotation, the lever arm of the abductor muscles is decreased, causing higher joint-reaction forces. Modular stems with varying lengths and geometries can be used to balance soft tissues, and ceramic bearing surfaces can be used to reduce the wear rate. Forty-four hip replacements performed with a high hip centre of rotation were matched with 44 performed with an anatomical centre of rotation. In all cases the preoperative diagnosis was dysplasia of the hip (DDH) and cementless modular neck prostheses with ceramic bearing surfaces were used. At nine years follow-up the mean Harris hip and WOMAC scores were not statistically different. All stems and cups were stable; the femoral offset was no different between the two groups (p = 0.4) as leg-length discrepancy (p = 0.25).

Entities:  

Mesh:

Year:  2008        PMID: 19099304      PMCID: PMC2899177          DOI: 10.1007/s00264-008-0710-0

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  24 in total

1.  High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. Results after a mean of ten years.

Authors:  J T Dearborn; W H Harris
Journal:  J Bone Joint Surg Am       Date:  1999-04       Impact factor: 5.284

2.  Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year follow-up.

Authors:  P Korovessis; G Petsinis; M Repanti; T Repantis
Journal:  J Bone Joint Surg Am       Date:  2006-06       Impact factor: 5.284

3.  Early diagnosis of ceramic liner fracture. Guidelines based on a twelve-year clinical experience.

Authors:  Aldo Toni; Francesco Traina; Susanna Stea; Alessandra Sudanese; Manuela Visentin; Barbara Bordini; Stefano Squarzoni
Journal:  J Bone Joint Surg Am       Date:  2006-12       Impact factor: 5.284

4.  Superior displacement of the hip in total joint replacement: effects of prosthetic neck length, neck-stem angle, and anteversion angle on the moment-generating capacity of the muscles.

Authors:  S L Delp; A V Komattu; R L Wixson
Journal:  J Orthop Res       Date:  1994-11       Impact factor: 3.494

5.  Results of total hip arthroplasty for Crowe Type III developmental hip dysplasia.

Authors:  A A Stans; M W Pagnano; W J Shaughnessy; A D Hanssen
Journal:  Clin Orthop Relat Res       Date:  1998-03       Impact factor: 4.176

6.  Influence of a high hip center on abductor muscle function.

Authors:  J Jerosch; J Steinbeck; J Stechmann; V Güth
Journal:  Arch Orthop Trauma Surg       Date:  1997       Impact factor: 3.067

7.  High placement of noncemented acetabular components in revision total hip arthroplasty. A concise follow-up, at a minimum of fifteen years, of a previous report.

Authors:  Kelly J Hendricks; William H Harris
Journal:  J Bone Joint Surg Am       Date:  2006-10       Impact factor: 5.284

8.  Compensating for changes in muscle length in total hip arthroplasty. Effects on the moment generating capacity of the muscles.

Authors:  A N Vasavada; S L Delp; W J Maloney; D J Schurman; F E Zajac
Journal:  Clin Orthop Relat Res       Date:  1994-05       Impact factor: 4.176

9.  The custom femoral component is an effective option for congenital hip dysplasia.

Authors:  Takashi Sakai; Nobuhiko Sugano; Kenji Ohzono; Seung Bak Lee; Takashi Nishii
Journal:  Clin Orthop Relat Res       Date:  2006-10       Impact factor: 4.176

10.  Influence of the acetabular cup position on hip load during arthroplasty in hip dysplasia.

Authors:  Goran Bicanic; Domagoj Delimar; Marko Delimar; Marko Pecina
Journal:  Int Orthop       Date:  2008-11-18       Impact factor: 3.075

View more
  19 in total

1.  Long-term survivorship and complication rate comparison of a cementless modular stem and cementless fixed neck stems for primary total hip replacement.

Authors:  David A Fitch; Cristina Ancarani; Barbara Bordini
Journal:  Int Orthop       Date:  2015-07-09       Impact factor: 3.075

2.  Cementless modular neck stems: are they a safe option in primary total hip arthroplasty?

Authors:  José M Pelayo-de-Tomás; José L Rodrigo-Pérez; Carlos D Novoa-Parra; Alejandro Lizaur-Utrilla; María Morales-Suárez-Varela; José Antonio Blas-Dobón
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-10-29

3.  Acetabuloplasty with bone grafting in uncemented hip replacement for protrusion.

Authors:  Sándor-György Zuh; Ancuţa Zazgyva; István Gergely; Tudor Sorin Pop
Journal:  Int Orthop       Date:  2015-05-29       Impact factor: 3.075

4.  Biomechanical reconstruction of the hip: comparison between modular short-stem hip arthroplasty and conventional total hip arthroplasty.

Authors:  Florian Schmidutz; Marc Beirer; Patrick Weber; Farhad Mazoochian; Andreas Fottner; Volkmar Jansson
Journal:  Int Orthop       Date:  2012-01-20       Impact factor: 3.075

5.  Effect of femoral neck modularity upon the prosthetic range of motion in total hip arthroplasty.

Authors:  Glen A Turley; Damian R Griffin; Mark A Williams
Journal:  Med Biol Eng Comput       Date:  2014-06-27       Impact factor: 2.602

6.  Total hip arthroplasty with a monoblock conical stem and subtrochanteric transverse shortening osteotomy in Crowe type IV dysplastic hips.

Authors:  Guido Grappiolo; Francesco La Camera; Antonello Della Rocca; Giuseppe Mazziotta; Giuseppe Santoro; Mattia Loppini
Journal:  Int Orthop       Date:  2018-09-05       Impact factor: 3.075

Review 7.  How have alternative bearings and modularity affected revision rates in total hip arthroplasty?

Authors:  William M Mihalko; Markus A Wimmer; Carol A Pacione; Michel P Laurent; Robert F Murphy; Carson Rider
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

8.  Does Cup Position at the High Hip Center or Anatomic Hip Center in THA for Developmental Dysplasia of the Hip Result in Better Harris Hip Scores and Revision Incidence? A Systematic Review.

Authors:  Patrick Stirling; Maria-Roxana Viamont-Guerra; Louise Strom; Antonia F Chen; Mo Saffarini; Luca Nover; Frederic Laude
Journal:  Clin Orthop Relat Res       Date:  2021-05-01       Impact factor: 4.176

Review 9.  Sciatic Nerve Palsy following Total Hip Replacement: Are Patients Personal Characteristics More Important than Limb Lengthening? A Systematic Review.

Authors:  Marcello De Fine; Matteo Romagnoli; Stefano Zaffagnini; Giovanni Pignatti
Journal:  Biomed Res Int       Date:  2017-11-15       Impact factor: 3.411

10.  A Dual Biomechanical Failure: Exeter Stem and Pubic Rami Insufficiency Fracture, following Hybrid Total Hip Arthroplasty.

Authors:  Inderpaul Samra; Christos Paliobeis
Journal:  Case Rep Orthop       Date:  2015-07-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.