Literature DB >> 15480869

[Peri-implant bone formation around cylindrical and conical implant systems].

A Büchter1, J Kleinheinz, H-P Wiesmann, L Seper, U Joos, U Meyer.   

Abstract

BACKGROUND: The treatment of patients with early or immediately loaded dental implants has renewed interest in the behavior of osseointegration at the implant surface. Whereas it is generally accepted that peri-implant tissue formation and mineralization are dependent on the local mechanical environment in the interface zone, controversies exist concerning the impact of implant design on peri-implant bone formation. The aim of the present study was the in vivo evaluation of peri-implant bone formation by two different implant systems: cylindrical (ITI) versus conical (ILI). MATERIAL AND
METHOD: A total of 60 implants (30 ITI and 30 ILI) were placed in the cranial and caudal part of the tibia of eight Göttinger minipigs. Half of the minipigs were sacrificed at 7 days and 28 days of osseointegration. Implant-containing bone specimens were prepared for histological and ultrastructural investigations.
RESULTS: Histological and scanning electron-microscopic investigations showed a direct contact of bone-like minerals over the whole implant surface from day 7 of implant/bone interaction. Whereas the ILI implant showed direct contact up to the top of the crestal bone, ITI implants demonstrated a crestally located narrow gap without ossification over the whole experimental period.
CONCLUSION: Our investigations support the hypothesis of an implant design-inherent emergence and maintenance of crestal bone.

Entities:  

Mesh:

Year:  2004        PMID: 15480869     DOI: 10.1007/s10006-004-0557-5

Source DB:  PubMed          Journal:  Mund Kiefer Gesichtschir        ISSN: 1432-9417


  21 in total

1.  Bone loading pattern around implants in average and atrophic edentulous maxillae: a finite-element analysis.

Authors:  Ulrich Meyer; Dirk Vollmer; Christoph Runte; Christoph Bourauel; Ulrich Joos
Journal:  J Maxillofac Surg       Date:  2001-04

2.  A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study.

Authors:  B Friberg; L Sennerby; N Meredith; U Lekholm
Journal:  Int J Oral Maxillofac Surg       Date:  1999-08       Impact factor: 2.789

3.  [Histological and histomorphometric results of implantation of dental implants by early and late implantation].

Authors:  A Gaggl; G Schultes; H Rainer; H Kärcher
Journal:  Mund Kiefer Gesichtschir       Date:  2000-09

4.  Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.

Authors:  D Buser; R K Schenk; S Steinemann; J P Fiorellini; C H Fox; H Stich
Journal:  J Biomed Mater Res       Date:  1991-07

5.  Stability assessments and histology of titanium implants placed simultaneously with autogenous onlay bone in the rabbit tibia.

Authors:  L Rasmusson; N Meredith; K E Kahnberg; L Sennerby
Journal:  Int J Oral Maxillofac Surg       Date:  1998-06       Impact factor: 2.789

6.  Sinus elevation procedures in the resorbed posterior maxilla. Comparison of the crestal and lateral approaches.

Authors:  N U Zitzmann; P Schärer
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1998-01

7.  Osseointegrated oral implants. A Swedish multicenter study of 8139 consecutively inserted Nobelpharma implants.

Authors:  T Albrektsson; E Dahl; L Enbom; S Engevall; B Engquist; A R Eriksson; G Feldmann; N Freiberg; P O Glantz; O Kjellman
Journal:  J Periodontol       Date:  1988-05       Impact factor: 6.993

8.  Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimens.

Authors:  B Friberg; L Sennerby; J Roos; U Lekholm
Journal:  Clin Oral Implants Res       Date:  1995-12       Impact factor: 5.977

9.  Effects of barrier membranes on bone resorption and implant stability in onlay bone grafts. An experimental study.

Authors:  L Rasmusson; N Meredith; K E Kahnberg; L Sennerby
Journal:  Clin Oral Implants Res       Date:  1999-08       Impact factor: 5.977

10.  Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man.

Authors:  T Albrektsson; P I Brånemark; H A Hansson; J Lindström
Journal:  Acta Orthop Scand       Date:  1981
View more
  4 in total

1.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

2.  Orthodontic mini-implant stability at different insertion depths : Sensitivity of three stability measurement methods.

Authors:  Manuel Nienkemper; Natascha Santel; Ralf Hönscheid; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2016-06-07       Impact factor: 1.938

3.  Peri-implant bone reactions around immediately loaded conical implants with different prosthetic suprastructures: histological and histomorphometrical study on minipigs.

Authors:  Bartolomeo Assenza; Antonio Scarano; Vittoria Perrotti; Iole Vozza; Alessandro Quaranta; Manlio Quaranta; Adriano Piattelli; Giovanna Iezzi
Journal:  Clin Oral Investig       Date:  2009-06-04       Impact factor: 3.573

4.  Measurement of mini-implant stability using resonance frequency analysis.

Authors:  Manuel Nienkemper; Benedict Wilmes; Agamemnon Panayotidis; Alexander Pauls; Vladimir Golubovic; Frank Schwarz; Dieter Drescher
Journal:  Angle Orthod       Date:  2012-08-29       Impact factor: 2.079

  4 in total