Literature DB >> 9662022

Stability assessments and histology of titanium implants placed simultaneously with autogenous onlay bone in the rabbit tibia.

L Rasmusson1, N Meredith, K E Kahnberg, L Sennerby.   

Abstract

A disc-shaped bone graft was harvested from the calvarium in ten rabbits and anchored as an onlay bone graft, using a titanium implant, at the proximal tibial metaphysis. The contralateral tibia served as the control, where an implant was placed without a graft with the implant head at a height corresponding to the thickness of the graft on the test side. Resonance frequency measurements were performed 4, 8, 16 and 24 weeks postoperatively and removal torque measurements were performed at 24 weeks. A statistically significant higher implant stability, as assessed by resonance frequency measurements (RFM), was measured from 4 weeks throughout the 24-week period. The mean peak removal torque for the test implants was 50.4+/-10.0 Ncm and 30.0+/-6.9 Ncm for the control implants, which was a statistically significant difference. Histologically, the grafted bone was well incorporated and morphometry revealed more bone around the test implants. Calculations of shear stresses indicated that the grafted bone had similar biomechanical properties to the cortical bone of the recipient site. It is concluded that the integration of titanium implants in autogenous onlay bone grafts results in an increased biomechanical support of the implant. The use of RFM may also serve as a useful instrument for noninvasive monitoring of implant stability in vivo.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9662022     DOI: 10.1016/s0901-5027(98)80019-2

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  7 in total

1.  [Primary implant stability with different bone surgery techniques. An in vitro study of the mandible of the minipig].

Authors:  A Büchter; J Kleinheinz; U Joos; U Meyer
Journal:  Mund Kiefer Gesichtschir       Date:  2003-10-24

2.  [Peri-implant bone formation around cylindrical and conical implant systems].

Authors:  A Büchter; J Kleinheinz; H-P Wiesmann; L Seper; U Joos; U Meyer
Journal:  Mund Kiefer Gesichtschir       Date:  2004-07-23

3.  The effect of various thread designs on the initial stability of taper implants.

Authors:  Ju-Hee Park; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

4.  Biological and biomechanical evaluation of interface reaction at conical screw-type implants.

Authors:  Andre Büchter; Ulrich Joos; Hans-Peter Wiesmann; László Seper; Ulrich Meyer
Journal:  Head Face Med       Date:  2006-02-21       Impact factor: 2.151

5.  Osseointegration of Titanium Implants in Onlay of Cerament™, a New Ceramic Bone Substitute.

Authors:  Anna Truedsson; Jian-Sheng Wang; Pia Lindberg; Gunnar Warfvinge
Journal:  J Funct Biomater       Date:  2016-01-07

6.  Resorption of retromolar bone grafts after alveolar ridge augmentation-volumetric changes after 12 months assessed by CBCT analysis.

Authors:  Andres Stricker; Reinhilde Jacobs; Frederik Maes; Tabea Fluegge; Kirstin Vach; Jonathan Fleiner
Journal:  Int J Implant Dent       Date:  2021-01-21

7.  RFA measurements of survival midpalatal orthodontic mini-implants in comparison to initial healing period.

Authors:  Manuel Nienkemper; Jan H Willmann; Kathrin Becker; Dieter Drescher
Journal:  Prog Orthod       Date:  2020-02-17       Impact factor: 2.750

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.