Literature DB >> 1538248

Continuous noninvasive cardiac output as estimated from the pulse contour curve.

I Gratz1, J Kraidin, A G Jacobi, N G deCastro, P Spagna, G E Larijani.   

Abstract

We developed a noninvasive computer-based system for estimating continuous cardiac output by a modified pulse contour method using a finger pressure waveform. The method requires no individual patient calibration or baseline cardiac output. First, we calibrated the system in a "learn" group of 20 patients. The computer-based cardiac output was then compared with thermodilution cardiac output in 27 patients undergoing coronary artery bypass surgery. A total of 94 cardiac outputs were performed (three averaged per determination) at four predetermined time periods: preinduction, postinduction, prebypass, and postbypass. During determination of each thermodilution cardiac output, the pulse wave data were simultaneously recorded on cassette tape. The patients had cardiac outputs ranging from 2.9 to 6.4 L/min. The correlation coefficient was 0.75. The average thermodilution cardiac output was 4.50 (+/- 0.83 SD) L/min, while the cardiac output derived from the finger pressure wave was 4.48 (+/- 0.7 SD) L/min (95% confidence interval [CI] of difference, 0-3.2%). The mean difference between the two methods was 0.02 (+/- 0.55 SD) L/min. The 95% CI for the bias was 0.0001 to 0.036 L/min. The 95% CI for the lower limit of agreement was -1.12 to -1.06 L/min; the upper limit for the 95% CI was 1.09 to 1.16 L/min. The program demonstrated that information about cardiac output can be obtained by using the Finapres device (Ohmeda, Boulder, CO). The cardiac output values obtained by this continuous noninvasive technique were within +/- 20% of the simultaneous thermodilution values 87% of the time. This was true over the narrow range of cardiac outputs (2.9 to 6.4 L/min) and wide range of heart rates (45 to 140 beats/min).

Entities:  

Mesh:

Year:  1992        PMID: 1538248     DOI: 10.1007/bf01618083

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  15 in total

1.  New noninvasive computerized method for the area measurement of the dicrotic notch.

Authors:  R E De Meersman
Journal:  Comput Biol Med       Date:  1989       Impact factor: 4.589

2.  Estimation of total arterial compliance: an improved method and evaluation of current methods.

Authors:  Z Liu; K P Brin; F C Yin
Journal:  Am J Physiol       Date:  1986-09

3.  Cardiac output determination: thermodilution versus a new computerized Fick method.

Authors:  J P Carpenter; S Nair; I Staw
Journal:  Crit Care Med       Date:  1985-07       Impact factor: 7.598

4.  Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger.

Authors:  K H Wesseling; J J Settels; G M van der Hoeven; J A Nijboer; M W Butijn; J C Dorlas
Journal:  Cardiovasc Res       Date:  1985-03       Impact factor: 10.787

5.  Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvre.

Authors:  B P Imholz; G A van Montfrans; J J Settels; G M van der Hoeven; J M Karemaker; W Wieling
Journal:  Cardiovasc Res       Date:  1988-06       Impact factor: 10.787

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

7.  Possibility of cardiac output monitoring from the intra-arterial blood pressure profile.

Authors:  C Alicandri; R Fariello; E Boni; A Zaninelli; G Muiesan
Journal:  Clin Exp Hypertens A       Date:  1985

8.  Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger.

Authors:  N T Smith; K H Wesseling; B de Wit
Journal:  J Clin Monit       Date:  1985-01

Review 9.  The arterial pulse in health and disease.

Authors:  M F O'Rourke
Journal:  Am Heart J       Date:  1971-11       Impact factor: 4.749

10.  Noninvasive continuous blood pressure measurement from the finger: optimal measurement conditions and factors affecting reliability.

Authors:  T Kurki; N T Smith; N Head; H Dec-Silver; A Quinn
Journal:  J Clin Monit       Date:  1987-01
View more
  13 in total

Review 1.  Cardiac output in 1998.

Authors:  M Singer
Journal:  Heart       Date:  1998-05       Impact factor: 5.994

2.  Lack of changes in carotid artery compliance with systemic nitric oxide synthase inhibition.

Authors:  J Sugawara; Y Saito; S Maeda; M Yoshizawa; H Komine; M Nakamura; R Ajisaka; H Tanaka
Journal:  J Hum Hypertens       Date:  2014-01-09       Impact factor: 3.012

3.  Detection of dicrotic notch in arterial pressure signals.

Authors:  S A Hoeksel; J R Jansen; J A Blom; J J Schreuder
Journal:  J Clin Monit       Date:  1997-09

4.  Noninvasive assessment of cardiac output from arterial pressure profiles during exercise.

Authors:  G Antonutto; M Girardis; D Tuniz; P E di Prampero
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1995

5.  Does peripheral nerve degeneration affect circulatory responses to head-up tilt in spinal cord-injured individuals?

Authors:  Jan T Groothuis; Cécile R L Boot; Sibrand Houtman; Herman van Langen; Maria T E Hopman
Journal:  Clin Auton Res       Date:  2005-04       Impact factor: 4.435

6.  Thermoregulatory vasoconstriction increases the difference between femoral and radial arterial pressures.

Authors:  J Urzua; D I Sessler; G Meneses; C M Sacco; R Canessa; G Lema
Journal:  J Clin Monit       Date:  1994-07

7.  Baroreflex-mediated changes in cardiac output and vascular conductance in response to alterations in carotid sinus pressure during exercise in humans.

Authors:  Shigehiko Ogoh; Paul J Fadel; Peter Nissen; Øeivind Jans; Christian Selmer; Niels H Secher; Peter B Raven
Journal:  J Physiol       Date:  2003-05-02       Impact factor: 5.182

8.  Multicenter evaluation of noninvasive cardiac output measurement by bioreactance technique.

Authors:  Nirav Y Raval; Pierre Squara; Michael Cleman; Kishore Yalamanchili; Michael Winklmaier; Daniel Burkhoff
Journal:  J Clin Monit Comput       Date:  2008-03-14       Impact factor: 2.502

9.  Noninvasive cardiac output monitoring (NICOM): a clinical validation.

Authors:  Pierre Squara; Dominique Denjean; Philippe Estagnasie; Alain Brusset; Jean Claude Dib; Claude Dubois
Journal:  Intensive Care Med       Date:  2007-04-26       Impact factor: 17.440

10.  Haemodynamic consequences of warm cardiac irrigation during cardiac surgery.

Authors:  N Lingaraju; J C Horrow; P Colonna-Romano; M D Strong
Journal:  Can J Anaesth       Date:  1994-05       Impact factor: 5.063

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.