Literature DB >> 8055604

Haemodynamic consequences of warm cardiac irrigation during cardiac surgery.

N Lingaraju1, J C Horrow, P Colonna-Romano, M D Strong.   

Abstract

Following cardiopulmonary bypass (CPB) and prior to closing the chest, some surgeons irrigate the heart and pericardium with warm saline. This prospective study, using each patient as his own control, evaluated the haemodynamic effects of warm (44 +/- 5 degrees C) irrigation on the heart and pericardium following CPB. Following discontinuation of CPB, a Mon-a-therm model 6500 thermocouple monitor measured the myocardial septum and the irrigating fluid temperatures. Immediately before, during and two minutes after irrigation of the heart and pericardium, we measured heart rate (HR), systemic blood pressure (BP), pulmonary artery pressure (PAP), central venous pressure (CVP), thermodilution cardiac output, and calculated systemic vascular resistance (SVR). During warm irrigation, HR increased from 93 +/- 15 to 101 +/- 13 min-1 and systolic BP increased from 111 +/- 17 to 131 +/- 27 mmHg. After irrigation, HR decreased to 96 +/- 12 min-1 with no change in systolic BP. The calculated SVR after irrigation increased to 1117 +/- 413 dynes.sec.cm-5 from the pre-irrigation value of 821 +/- 243 dynes.sec.cm-5, while cardiac index decreased to 2.4 L.min-1.m-2 from its pre-irrigation value of 2.99 L.min-1.m-2. Warm irrigation of the pericardial pouch causes tachycardic and hypertensive responses in patients undergoing cardiac surgery.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8055604     DOI: 10.1007/BF03009859

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  6 in total

1.  Continuous cardiac output monitoring by pulse contour during cardiac surgery.

Authors:  J R Jansen; K H Wesseling; J J Settels; J J Schreuder
Journal:  Eur Heart J       Date:  1990-12       Impact factor: 29.983

2.  Comparison of bioimpedance and thermodilution measurements of cardiac output during aortic surgery.

Authors:  P J Sullivan; R J Martineau; K A Hull; D R Miller
Journal:  Can J Anaesth       Date:  1990-05       Impact factor: 5.063

3.  Validity of cardiac output measurement by computer-averaged impedance cardiography, and comparison with simultaneous thermodilution determinations.

Authors:  B R Pickett; J C Buell
Journal:  Am J Cardiol       Date:  1992-05-15       Impact factor: 2.778

Review 4.  Limitations of cardiac output measurements by thermodilution.

Authors:  S Nadeau; W H Noble
Journal:  Can Anaesth Soc J       Date:  1986-11

5.  Postoperative myocardial ischemia in patients undergoing coronary artery bypass graft surgery. S.P.I. Research Group.

Authors:  R C Smith; J M Leung; D T Mangano
Journal:  Anesthesiology       Date:  1991-03       Impact factor: 7.892

6.  Continuous noninvasive cardiac output as estimated from the pulse contour curve.

Authors:  I Gratz; J Kraidin; A G Jacobi; N G deCastro; P Spagna; G E Larijani
Journal:  J Clin Monit       Date:  1992-01
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.