Literature DB >> 3224351

Continuous non-invasive blood pressure monitoring: reliability of Finapres device during the Valsalva manoeuvre.

B P Imholz1, G A van Montfrans, J J Settels, G M van der Hoeven, J M Karemaker, W Wieling.   

Abstract

Because of the inherent risks of intra-arterial blood pressure monitoring a new non-invasive device, Finapres, which measures blood pressure continuously in the finger, was evaluated in 14 hypertensive and one normotensive subject. Brachial intra-arterial and finger pressures were compared during a control period and a subsequent Valsalva manoeuvre. Visually, blood pressures measured by Finapres faithfully reproduced the intra-arterial recordings in all subjects. From each pressure signal beat to beat systolic, diastolic, and mean blood pressure values and their differences were obtained and the time course of the response and its characteristic features were analysed. During the control period the Finapres measurements were lower than intra-arterial systolic, mean, and diastolic pressures (mean(SD) 1(9.6), 9(6.8), and 4(6.1) mmHg respectively). During the response to the Valsalva manoeuvre the brachial-finger pressure differences showed limited deviation from those during the control period; median differences were at most 6 mmHg occurring late during the intrathoracic strain period and 7 mmHg during the post-release blood pressure overshoot. In general, the Finapres device reproduced intra-arterial patterns faithfully. This device appears to offer a reliable alternative to intra-arterial blood pressure monitoring.

Entities:  

Mesh:

Year:  1988        PMID: 3224351     DOI: 10.1093/cvr/22.6.390

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  46 in total

1.  Non-invasive assessment of autonomic nervous system integrity in able-bodied and spinal cord-injured individuals.

Authors:  S Houtman; B Oeseburg; M T Hopman
Journal:  Clin Auton Res       Date:  1999-06       Impact factor: 4.435

2.  Influence of microgravity on astronauts' sympathetic and vagal responses to Valsalva's manoeuvre.

Authors:  James F Cox; Kari U O Tahvanainen; Tom A Kuusela; Benjamin D Levine; William H Cooke; Tadaaki Mano; Satoshi Iwase; Mitsuru Saito; Yoshiki Sugiyama; Andrew C Ertl; Italo Biaggioni; André Diedrich; Rose Marie Robertson; Julie H Zuckerman; Lynda D Lane; Chester A Ray; Ronald J White; James A Pawelczyk; Jay C Buckey; Friedhelm J Baisch; C Gunnar Blomqvist; David Robertson; Dwain L Eckberg
Journal:  J Physiol       Date:  2002-01-01       Impact factor: 5.182

3.  Assessment of short-term blood pressure variability in anesthetized children: a comparative study between intraarterial and finger blood pressure.

Authors:  I Constant; D Laude; J L Elghozi; I Murat
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

4.  Arterial pressure oscillations are not associated with muscle sympathetic nerve activity in individuals exposed to central hypovolaemia.

Authors:  Kathy L Ryan; Caroline A Rickards; Carmen Hinojosa-Laborde; William H Cooke; Victor A Convertino
Journal:  J Physiol       Date:  2011-09-19       Impact factor: 5.182

5.  Effects of inspiratory impedance on hemodynamic responses to a squat-stand test in human volunteers: implications for treatment of orthostatic hypotension.

Authors:  Victor A Convertino; Duane A Ratliff; Jacqueline Crissey; Donald F Doerr; Ahamed H Idris; Keith G Lurie
Journal:  Eur J Appl Physiol       Date:  2005-04-28       Impact factor: 3.078

6.  Continuous finger arterial pressure: utility in the cardiovascular laboratory.

Authors:  B P Imholz; W Wieling; G J Langewouters; G A van Montfrans
Journal:  Clin Auton Res       Date:  1991-03       Impact factor: 4.435

7.  Fluctuations in blood flow to acral skin in humans: connection with heart rate and blood pressure variability.

Authors:  K Lossius; M Eriksen; L Walløe
Journal:  J Physiol       Date:  1993-01       Impact factor: 5.182

8.  Non-invasive estimation of cardiac output in critical care patients.

Authors:  U M Gerhardt; C Schöller; D Böcker; H Hohage
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

9.  Circulatory response evoked by a 3 s bout of dynamic leg exercise in humans.

Authors:  W Wieling; M P Harms; A D ten Harkel; J J van Lieshout; R L Sprangers
Journal:  J Physiol       Date:  1996-07-15       Impact factor: 5.182

10.  Accuracy of beat-to-beat noninvasive measurement of finger arterial pressure using the Finapres: a spectral analysis approach.

Authors:  V Novak; P Novak; R Schondorf
Journal:  J Clin Monit       Date:  1994-03
View more