Literature DB >> 8789565

Noninvasive assessment of cardiac output from arterial pressure profiles during exercise.

G Antonutto1, M Girardis, D Tuniz, P E di Prampero.   

Abstract

The stroke volume of the left ventricle (SV) was assessed in nine young men (mean age 22.2, ranging from 20 to 25 years) during cycle ergometer upright exercise at exercise intensities from 60 to 150 W (about 20% to 80% of individual maximal aerobic power). The SV was calculated from noninvasive tracings of the arterial blood pressure, determined from photoplethysmograph records and compared to the SV determined simultaneously by pulsed Doppler echocardiography (PDE). Given the relationship SV = As.Z-1 in which A(s) is the area underneath the systolic pressure profile (in millimetres of mercury and second), and Z (in millimetres of mercury and second per millilitre) is the apparent hydraulic impedance of the circulatory system, a prerequisite for the assessment of SV from the photoplethysmograph tracings is a knowledge of Z. The experimental value of Z (hereafter defined Z*) was calculated by dividing A(s) (from the finger photoplethysmograph) by SV as obtained by PDE. When the whole group of subjects was considered, Z* was not greatly affected by the exercise intensity: it amounted to 0.089 (SD 0.028; n = 36). The Z was also estimated independently of any parameter other than heart rate (HR), mean (MAP) and pulse (PP) arterial blood pressure obtained from the photoplethysmograph. A computerized statistical method allowed us to interpolate the experimental values of Z*, HR, PP and MAP by the equation Zm = a.(b + c.HR + d.PP + e.MAP)-1, thus obtaining the coefficients a to e. The mean percentage error between Zm (calculated from the coefficients obtained and Z* was 21.8 (SD 14.3)%. However, it was observed that, in a given subject, Z* was significantly affected by the exercise intensity. Therefore, to improve the estimate of Z a second algorithm was developed to update the experimental value of Z determined initially at rest (Zin). This updated value (Zcor) of Z was calculated as Zcor = Zin. [(f/(i + g.(HR/HRin) + h.(PP/PPin) + 1.(MAP/MAPin)], where HRin, PPin, MAPin, HR, PP, MAP are the above parameters at rest and during exercise, respectively. Also in this case, the coefficients f to 1 were determined by a computerized statistical method using Z* as the experimental reference. The values of Zcor so obtained allowed us to calculate SV from arterial pulse contour analysis as SVF = As.Z-1cor. The mean percentage error between the SVF obtained and the values simultaneously determined by PDE, was 10.0 (SD 8.7)%. It is concluded that the SV of the left ventricle, and hence cardiac output, can be determined during exercise from photoplethysmograph tracings with reasonable accuracy, provided that an initial estimate of SV at rest is made by means an independent high quality reference method.

Entities:  

Mesh:

Year:  1995        PMID: 8789565     DOI: 10.1007/bf00964109

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  18 in total

1.  On the reliability of the Penaz cuff during systemic and local fingertip vasodilatation at rest and in exercise.

Authors:  W Hildebrandt; H Schütze; J Stegemann
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1991

2.  A formula to estimate the approximate surface area if height and weight be known. 1916.

Authors:  D Du Bois; E F Du Bois
Journal:  Nutrition       Date:  1989 Sep-Oct       Impact factor: 4.008

3.  Determination of stroke volume and cardiac output during exercise: comparison of two-dimensional and Doppler echocardiography, Fick oximetry, and thermodilution.

Authors:  J Christie; L M Sheldahl; F E Tristani; K B Sagar; M J Ptacin; S Wann
Journal:  Circulation       Date:  1987-09       Impact factor: 29.690

Review 4.  Continuous cardiac output derived from the aortic pressure waveform: a review of current methods.

Authors:  W W Nichols
Journal:  Biomed Eng       Date:  1973-09

5.  Effects of peripheral vasoconstriction on the measurement of blood pressure in a finger.

Authors:  K H Wesseling; J J Settels; G M van der Hoeven; J A Nijboer; M W Butijn; J C Dorlas
Journal:  Cardiovasc Res       Date:  1985-03       Impact factor: 10.787

6.  Clinical assessment of cardiac output.

Authors:  J Conway
Journal:  Eur Heart J       Date:  1990-12       Impact factor: 29.983

Review 7.  Doppler ultrasonic measurement of cardiac output: reproducibility and validation.

Authors:  A J Coats
Journal:  Eur Heart J       Date:  1990-12       Impact factor: 29.983

8.  Assessment of cardiac output at rest and during exercise by a carbon dioxide rebreathing method.

Authors:  T Reybrouck; R Fagard
Journal:  Eur Heart J       Date:  1990-12       Impact factor: 29.983

9.  Noninvasive continuous blood pressure measurement from the finger: optimal measurement conditions and factors affecting reliability.

Authors:  T Kurki; N T Smith; N Head; H Dec-Silver; A Quinn
Journal:  J Clin Monit       Date:  1987-01

10.  Continuous noninvasive cardiac output as estimated from the pulse contour curve.

Authors:  I Gratz; J Kraidin; A G Jacobi; N G deCastro; P Spagna; G E Larijani
Journal:  J Clin Monit       Date:  1992-01
View more
  7 in total

Review 1.  Cardiovascular deconditioning in microgravity: some possible countermeasures.

Authors:  G Antonutto; P E di Prampero
Journal:  Eur J Appl Physiol       Date:  2003-07-08       Impact factor: 3.078

2.  Effects of the muscle pump and body posture on cardiovascular responses during recovery from cycle exercise.

Authors:  Tatsuhisa Takahashi; Junichiro Hayano; Akiyoshi Okada; Tadashi Saitoh; Akira Kamiya
Journal:  Eur J Appl Physiol       Date:  2005-06-01       Impact factor: 3.078

3.  Mitochondrial coupling in humans: assessment of the P/O2 ratio at the onset of calf exercise.

Authors:  V Cettolo; M Cautero; E Tam; M P Francescato
Journal:  Eur J Appl Physiol       Date:  2007-01-06       Impact factor: 3.078

4.  The interplay of central and peripheral factors in limiting maximal O2 consumption in man after prolonged bed rest.

Authors:  G Ferretti; G Antonutto; C Denis; H Hoppeler; A E Minetti; M V Narici; D Desplanches
Journal:  J Physiol       Date:  1997-06-15       Impact factor: 5.182

5.  Factors determining the time course of VO2(max) decay during bedrest: implications for VO2(max) limitation.

Authors:  C Capelli; G Antonutto; M Azabji Kenfack; M Cautero; F Lador; C Moia; E Tam; G Ferretti
Journal:  Eur J Appl Physiol       Date:  2006-08-19       Impact factor: 3.078

6.  Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound.

Authors:  Johannes J van Lieshout; Karin Toska; Erik Jan van Lieshout; Morten Eriksen; Lars Walløe; Karel H Wesseling
Journal:  Eur J Appl Physiol       Date:  2003-07-08       Impact factor: 3.078

Review 7.  Noninvasive continuous hemodynamic monitoring.

Authors:  Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Journal:  J Clin Monit Comput       Date:  2012-06-14       Impact factor: 2.502

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.