The use of reference image criteria in X-ray diagnostics: an application for the optimisation of lumbar spine radiographs.

A Almén1, A Tingberg, J Besjakov, S Mattsson.   

Abstract

To ensure that sufficient image quality is obtained in diagnostic radiology, the image quality of clinical radiographs has to be evaluated. We present two methods herein for evaluating antero-posterior (AP) radiographs of the lumbar spine. One was using image criteria, including six anatomical details (absolute method). In the other, the visibility of anatomical details relative to a reference radiograph was evaluated (visual grading analysis). In total, 14 technique groups were evaluated. The technique groups differed in tube voltage and detector system characteristics. Six different gradients of the H&D curves were simulated. The visual grading analysis showed larger differences in image quality compared with the absolute method. The influence on the image quality due to a variation in tube voltage was easier to detect than the influence on the image quality from the detector characteristics. The visibility of the anatomical details was significantly dependent on the location in the spine. The visual grading analysis was found to be the preferable evaluation method in studies such as the present; however, it is necessary to guide and train the observer before the evaluation is performed.

Entities:  

Mesh:

Year:  2004        PMID: 15057564     DOI: 10.1007/s00330-004-2320-6

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  12 in total

1.  Report of an image quality and dose audit according to directive 97/43/Euratom at Spanish private radiodiagnostics facilities.

Authors:  L González; E Vañó; S Oliete; J Manrique; J M Hernáez; J Lahuerta; J Ruiz
Journal:  Br J Radiol       Date:  1999-02       Impact factor: 3.039

2.  Image quality for five modern chest radiography techniques: a modified FROC study with an anthropomorphic chest phantom.

Authors:  L G Månsson; S Kheddache; B Lanhede; U Tylén
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

3.  The influence of different technique factors on image quality of lumbar spine radiographs as evaluated by established CEC image criteria.

Authors:  A Almén; A Tingberg; S Mattsson; J Besjakov; S Kheddache; B Lanhede; L G Månsson; M Zankl
Journal:  Br J Radiol       Date:  2000-11       Impact factor: 3.039

4.  Comparison of entrance surface doses of some X ray examinations with CEC reference doses.

Authors:  A O Ogunseyinde; S A M Adeniran; R I Obed; B I Akinlade; F O Ogundare
Journal:  Radiat Prot Dosimetry       Date:  2002       Impact factor: 0.972

5.  Image quality vs. radiation dose for a flat-panel amorphous silicon detector: a phantom study.

Authors:  H Geijer; K W Beckman; T Andersson; J Persliden
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

6.  The influence of different technique factors on image quality of chest radiographs as evaluated by modified CEC image quality criteria.

Authors:  B Lanhede; M Båth; S Kheddache; P Sund; L Björneld; M Widell; A Almén; J Besjakov; S Mattsson; A Tingberg; C Herrmann; W Panzer; M Zankl; L G Månsson
Journal:  Br J Radiol       Date:  2002-01       Impact factor: 3.039

7.  Patient dose, image quality and radiographic techniques for common X ray examinations in two Greek hospitals and comparison with European guidelines.

Authors:  D Papadimitriou; A Perris; M G Molfetas; N Panagiotakis; A Manetou; G Tsourouflis; J Vassileva; P Chronopoulos; O Karapanagiotou; S Kottou
Journal:  Radiat Prot Dosimetry       Date:  2001       Impact factor: 0.972

8.  Selenium radiography versus storage phosphor and conventional radiography in the detection of simulated chest lesions.

Authors:  C M Schaefer-Prokop; M Prokop; A Schmidt; U Neitzel; M Galanski
Journal:  Radiology       Date:  1996-10       Impact factor: 11.105

9.  Patient dose and image quality in five standard x-ray examinations.

Authors:  R Havukainen; M Pirinen
Journal:  Med Phys       Date:  1993 May-Jun       Impact factor: 4.071

10.  Experiences with the European guidelines on quality criteria for radiographic images in Tanzania.

Authors:  W E Muhogora; A M Nyanda; R R Kazema
Journal:  J Appl Clin Med Phys       Date:  2001       Impact factor: 2.102

View more
  3 in total

Review 1.  Degenerative disorders of the spine.

Authors:  Massimo Gallucci; Edoardo Puglielli; Alessandra Splendiani; Francesca Pistoia; Giorgio Spacca
Journal:  Eur Radiol       Date:  2004-12-31       Impact factor: 5.315

Review 2.  Review of radiological scoring methods of osteoporotic vertebral fractures for clinical and research settings.

Authors:  Ling Oei; Fernando Rivadeneira; Felisia Ly; Stephan J Breda; M Carola Zillikens; Albert Hofman; André G Uitterlinden; Gabriel P Krestin; Edwin H G Oei
Journal:  Eur Radiol       Date:  2012-08-15       Impact factor: 5.315

3.  Intervariability in radiographic parameters and general evaluation of a low-dose fluoroscopic technique in patients with idiopathic scoliosis.

Authors:  Christian Wong; Jens Adriansen; Jytte Jeppsen; Andreas Balslev-Clausen
Journal:  Acta Radiol Open       Date:  2021-09-25
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.