Literature DB >> 10365071

Report of an image quality and dose audit according to directive 97/43/Euratom at Spanish private radiodiagnostics facilities.

L González1, E Vañó, S Oliete, J Manrique, J M Hernáez, J Lahuerta, J Ruiz.   

Abstract

An audit of Spanish private medicine radiodiagnostics facilities has been carried out, based partly on Spanish legislation relating to European Directives on health protection against ionizing radiation risks in medical exposure. The study included an appraisal of infrastructure and equipment, and aspects of quality assurance and radiation protection, by means of data collected through surveys. Of the 51 centres audited, a sample of 24 X-ray rooms was chosen, then an external evaluation with regard to image quality and patient dose was performed, by an advisory board of radiologists and medical physicists. The methodology used was similar to that of the group of European Union experts in European dose evaluation and image quality trials. Chest, abdomen, lumbar spine and breast examinations were monitored. Doses were measured with thermoluminescent dosimeters. A third of the X-ray rooms evaluated reached or exceeded dose reference values, and in a third of the cases the image quality left considerable room for improvement. Breast and chest examinations showed themselves to be the hardest to perform, not only as a result of exceeding the reference doses, but also due to failure to meet good image quality standards.

Entities:  

Mesh:

Year:  1999        PMID: 10365071     DOI: 10.1259/bjr.72.854.10365071

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  The use of reference image criteria in X-ray diagnostics: an application for the optimisation of lumbar spine radiographs.

Authors:  A Almén; A Tingberg; J Besjakov; S Mattsson
Journal:  Eur Radiol       Date:  2004-04-01       Impact factor: 5.315

2.  Impact of a training course on the quality of chest radiography to diagnose pulmonary tuberculosis.

Authors:  A Ohkado; P Luna; A Querri; M Mercader; S Yoshimatsu; L Coprada; R Bañares; A M C Garfin; T Date
Journal:  Public Health Action       Date:  2015-03-21

Review 3.  Reconstruction of absorbed doses to fibroglandular tissue of the breast of women undergoing mammography (1960 to the present).

Authors:  Isabelle Thierry-Chef; Steven L Simon; Robert M Weinstock; Deukwoo Kwon; Martha S Linet
Journal:  Radiat Res       Date:  2011-10-12       Impact factor: 2.841

4.  European guidelines on quality criteria for diagnostic radiographic images of the lumbar spine - an intra- and inter-observer reproducibility study.

Authors:  Klaus Doktor; Maria Lind Vilholm; Aldis Hardardóttir; Henrik Wulff Christensen; Jens Lauritsen
Journal:  Chiropr Man Therap       Date:  2019-05-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.