Literature DB >> 2319933

Extraction of cardiac and respiratory motion cycles by use of projection data and its applications to NMR imaging.

W S Kim1, C W Mun, D J Kim, Z H Cho.   

Abstract

A technique of extracting cardiac and respiratory motion cycles by use of projection data is proposed and studied. These extracted cardiac and respiratory motion cycles are applied to the cine imaging of heart and motion artifact reduction in abdominal imaging instead of the conventional ECG gating devices. The basic concepts and their applications are discussed. Experimental results on human volunteers obtained with the KAIS 2.0-T whole-body NMR imaging system together with the pulse sequences used for the experiments are presented.

Entities:  

Mesh:

Year:  1990        PMID: 2319933     DOI: 10.1002/mrm.1910130105

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  11 in total

1.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

2.  Respiration artifact correction in three-dimensional proton resonance frequency MR thermometry using phase navigators.

Authors:  Bryant T Svedin; Allison Payne; Dennis L Parker
Journal:  Magn Reson Med       Date:  2015-08-13       Impact factor: 4.668

3.  Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.

Authors:  Jing Liu; Pascal Spincemaille; Noel C F Codella; Thanh D Nguyen; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

4.  Multiple-mouse MRI with multiple arrays of receive coils.

Authors:  Marc S Ramirez; Emilio Esparza-Coss; James A Bankson
Journal:  Magn Reson Med       Date:  2010-03       Impact factor: 4.668

5.  Modified ventilator with logic controller for cardiorespiratory synchronisation of magnetic resonance imaging in small animals.

Authors:  J R Grove; A Behbin; J Kost
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

6.  Self-gated golden angle spiral cine MRI for coronary endothelial function assessment.

Authors:  Gabriele Bonanno; Allison G Hays; Robert G Weiss; Michael Schär
Journal:  Magn Reson Med       Date:  2017-12-27       Impact factor: 4.668

7.  Self-gated fat-suppressed cardiac cine MRI.

Authors:  R Reeve Ingle; Juan M Santos; William R Overall; Michael V McConnell; Bob S Hu; Dwight G Nishimura
Journal:  Magn Reson Med       Date:  2014-05-07       Impact factor: 4.668

8.  Free breathing three-dimensional late gadolinium enhancement cardiovascular magnetic resonance using outer volume suppressed projection navigators.

Authors:  Rajiv G Menon; G Wilson Miller; Jean Jeudy; Sanjay Rajagopalan; Taehoon Shin
Journal:  Magn Reson Med       Date:  2016-04-28       Impact factor: 4.668

9.  Wireless self-gated multiple-mouse cardiac cine MRI.

Authors:  Emilio Esparza-Coss; Marc S Ramirez; James A Bankson
Journal:  Magn Reson Med       Date:  2008-05       Impact factor: 4.668

10.  Three-dimensional, in vivo MRI with self-gating and image coregistration in the mouse.

Authors:  Brian J Nieman; Kamila U Szulc; Daniel H Turnbull
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.