Fei Han1,2, Ziwu Zhou1,2, Eric Han3, Yu Gao1,4, Kim-Lien Nguyen1,5, J Paul Finn1, Peng Hu1,4. 1. Department of Radiological Sciences, David Geffen School of Medicine, University of California, Los Angeles, California, USA. 2. Department of Bioengineering, University of California, Los Angeles, California, USA. 3. Harvard Westlake School, Los Angeles, California, USA. 4. Biomedical Physics Inter-Departmental Graduate Program, University of California, Los Angeles, California, USA. 5. Division of Cardiology, VA Greater Los Angeles Healthcare System, Los Angeles, California, USA.
Abstract
PURPOSE: To develop and validate a cardiac-respiratory self-gating strategy for the recently proposed multiphase steady-state imaging with contrast enhancement (MUSIC) technique. METHODS: The proposed SG strategy uses the ROtating Cartesian K-space (ROCK) sampling, which allows for retrospective k-space binning based on motion surrogates derived from k-space center line. The k-space bins are reconstructed using a compressed sensing algorithm. Ten pediatric patients underwent cardiac MRI for clinical reasons. The original MUSIC and 2D-CINE images were acquired as a part of the clinical protocol, followed by the ROCK-MUSIC acquisition, all under steady-state intravascular distribution of ferumoxytol. Subjective scores and image sharpness were used to compare the images of ROCK-MUSIC and original MUSIC. RESULTS: All scans were completed successfully without complications. The ROCK-MUSIC acquisition took 5 ± 1 min, compared to 8 ± 2 min for the original MUSIC. Image scores of ROCK-MUSIC were significantly better than original MUSIC at the ventricular outflow tracts (3.9 ± 0.3 vs. 3.3 ± 0.6, P < 0.05). There was a strong trend toward superior image scores for ROCK-MUSIC in the other anatomic locations. CONCLUSION: ROCK-MUSIC provided images of equal or superior image quality compared to original MUSIC, and this was achievable with 40% savings in scan time and without the need for physiologic signal. Magn Reson Med 78:472-483, 2017.
PURPOSE: To develop and validate a cardiac-respiratory self-gating strategy for the recently proposed multiphase steady-state imaging with contrast enhancement (MUSIC) technique. METHODS: The proposed SG strategy uses the ROtating Cartesian K-space (ROCK) sampling, which allows for retrospective k-space binning based on motion surrogates derived from k-space center line. The k-space bins are reconstructed using a compressed sensing algorithm. Ten pediatric patients underwent cardiac MRI for clinical reasons. The original MUSIC and 2D-CINE images were acquired as a part of the clinical protocol, followed by the ROCK-MUSIC acquisition, all under steady-state intravascular distribution of ferumoxytol. Subjective scores and image sharpness were used to compare the images of ROCK-MUSIC and original MUSIC. RESULTS: All scans were completed successfully without complications. The ROCK-MUSIC acquisition took 5 ± 1 min, compared to 8 ± 2 min for the original MUSIC. Image scores of ROCK-MUSIC were significantly better than original MUSIC at the ventricular outflow tracts (3.9 ± 0.3 vs. 3.3 ± 0.6, P < 0.05). There was a strong trend toward superior image scores for ROCK-MUSIC in the other anatomic locations. CONCLUSION: ROCK-MUSIC provided images of equal or superior image quality compared to original MUSIC, and this was achievable with 40% savings in scan time and without the need for physiologic signal. Magn Reson Med 78:472-483, 2017.
Authors: Joseph Y Cheng; Tao Zhang; Nichanan Ruangwattanapaisarn; Marcus T Alley; Martin Uecker; John M Pauly; Michael Lustig; Shreyas S Vasanawala Journal: J Magn Reson Imaging Date: 2014-10-20 Impact factor: 4.813
Authors: Li Feng; Robert Grimm; Kai Tobias Block; Hersh Chandarana; Sungheon Kim; Jian Xu; Leon Axel; Daniel K Sodickson; Ricardo Otazo Journal: Magn Reson Med Date: 2013-10-18 Impact factor: 4.668
Authors: Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig Journal: Magn Reson Med Date: 2014-03 Impact factor: 4.668
Authors: Fei Han; Stanislas Rapacchi; Sarah Khan; Ihab Ayad; Isidro Salusky; Simon Gabriel; Adam Plotnik; J Paul Finn; Peng Hu Journal: Magn Reson Med Date: 2014-10-09 Impact factor: 4.668
Authors: Frank Ong; Xucheng Zhu; Joseph Y Cheng; Kevin M Johnson; Peder E Z Larson; Shreyas S Vasanawala; Michael Lustig Journal: Magn Reson Med Date: 2020-04-09 Impact factor: 4.668
Authors: Jens Wetzl; Michaela Schmidt; François Pontana; Benjamin Longère; Felix Lugauer; Andreas Maier; Joachim Hornegger; Christoph Forman Journal: MAGMA Date: 2017-05-26 Impact factor: 2.310
Authors: Jing Liu; Li Feng; Hsin-Wei Shen; Chengcheng Zhu; Yan Wang; Kanae Mukai; Gabriel C Brooks; Karen Ordovas; David Saloner Journal: MAGMA Date: 2017-01-24 Impact factor: 2.310
Authors: Tevfik F Ismail; Wendy Strugnell; Chiara Coletti; Maša Božić-Iven; Sebastian Weingärtner; Kerstin Hammernik; Teresa Correia; Thomas Küstner Journal: Front Cardiovasc Med Date: 2022-03-03
Authors: Kim-Lien Nguyen; Takegawa Yoshida; Nikhita Kathuria-Prakash; Islam H Zaki; Csanad G Varallyay; Scott I Semple; Rola Saouaf; Cynthia K Rigsby; Sokratis Stoumpos; Kevin K Whitehead; Lindsay M Griffin; David Saloner; Michael D Hope; Martin R Prince; Mark A Fogel; Mark L Schiebler; Giles H Roditi; Aleksandra Radjenovic; David E Newby; Edward A Neuwelt; Mustafa R Bashir; Peng Hu; J Paul Finn Journal: Radiology Date: 2019-10-22 Impact factor: 11.105
Authors: Aaron Pruitt; Adam Rich; Yingmin Liu; Ning Jin; Lee Potter; Matthew Tong; Saurabh Rajpal; Orlando Simonetti; Rizwan Ahmad Journal: Magn Reson Med Date: 2020-09-30 Impact factor: 4.668