Literature DB >> 22042429

Self-gated PROPELLER-encoded cine cardiac imaging.

Chi-Chung Wang1, Teng-Yi Huang.   

Abstract

This study uses the k-space center over-sampling property of PROPELLER encoding to detect cardiac and respiratory motion using raw k-space data. Using the motion information, cine cardiac imaging is self-gated. The data acquisition process requires neither electrocardiography triggering nor patient breath-holding. Using physiology motion information, this post-processing method rearranges the k-space data into groups corresponding to cardiac and respiratory phases. The PROPELLER blades of the same groups are combined to produce cine high-resolution images. This approach reduces the potential discrepancy of the k-space data and the motion-related artifacts in the reconstructed image because all blades in a group are acquired at consistent cardiac and respiratory phases. The study concludes that self-gated cine cardiac imaging is feasible using PROPELLER encoding. It is a potentially practical tool for cine cardiac imaging.

Entities:  

Mesh:

Year:  2011        PMID: 22042429     DOI: 10.1007/s10554-011-9969-0

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  25 in total

1.  Assessment of regional differences in myocardial blood flow using T2-weighted 3D BOLD imaging.

Authors:  K B Wright; F J Klocke; V S Deshpande; J Zheng; K R Harris; R Tang; J P Finn; D Li
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

2.  Multishot diffusion-weighted FSE using PROPELLER MRI.

Authors:  James G Pipe; Victoria G Farthing; Kirsten P Forbes
Journal:  Magn Reson Med       Date:  2002-01       Impact factor: 4.668

3.  PROPELLER EPI: an MRI technique suitable for diffusion tensor imaging at high field strength with reduced geometric distortions.

Authors:  Fu-Nien Wang; Teng-Yi Huang; Fa-Hsuan Lin; Tzu-Chao Chuang; Nan-Kuei Chen; Hsiao-Wen Chung; Cheng-Yu Chen; Kenneth K Kwong
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

4.  T2 measurement of the human myocardium using a T2-prepared transient-state TrueFISP sequence.

Authors:  Teng-Yi Huang; Yi-Jui Liu; Alto Stemmer; Brigitte P Poncelet
Journal:  Magn Reson Med       Date:  2007-05       Impact factor: 4.668

5.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

6.  Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition.

Authors:  Jing Liu; Pascal Spincemaille; Noel C F Codella; Thanh D Nguyen; Martin R Prince; Yi Wang
Journal:  Magn Reson Med       Date:  2010-05       Impact factor: 4.668

7.  ECG-synchronized cardiac MR imaging: method and evaluation.

Authors:  P Lanzer; C Barta; E H Botvinick; H U Wiesendanger; G Modin; C B Higgins
Journal:  Radiology       Date:  1985-06       Impact factor: 11.105

8.  Total removal of unwanted harmonic peaks (TruHARP) MRI for single breath-hold high-resolution myocardial motion and strain quantification.

Authors:  Harsh K Agarwal; Jerry L Prince; Khaled Z Abd-Elmoniem
Journal:  Magn Reson Med       Date:  2010-08       Impact factor: 4.668

9.  Single breath-hold multiarterial dynamic MRI of the liver at 3T using a 3D fat-suppressed keyhole technique.

Authors:  Hye-Suk Hong; Hua Sun Kim; Myeong-Jin Kim; Jan De Becker; Donald G Mitchell; Masayuki Kanematsu
Journal:  J Magn Reson Imaging       Date:  2008-08       Impact factor: 4.813

10.  Automated rectilinear self-gated cardiac cine imaging.

Authors:  Mark E Crowe; Andrew C Larson; Qiang Zhang; James Carr; Richard D White; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-10       Impact factor: 4.668

View more
  4 in total

Review 1.  Motion correction options in PET/MRI.

Authors:  Ciprian Catana
Journal:  Semin Nucl Med       Date:  2015-05       Impact factor: 4.446

2.  Pseudo-projection-driven, self-gated cardiac cine imaging using cartesian golden step phase encoding.

Authors:  Liheng Guo; J Andrew Derbyshire; Daniel A Herzka
Journal:  Magn Reson Med       Date:  2015-10-31       Impact factor: 4.668

3.  Self-Gated Late Gadolinium Enhancement at 7T to Image Rats with Reperfused Acute Myocardial Infarction.

Authors:  Lei Wang; Yushu Chen; Bing Zhang; Wei Chen; Chunhua Wang; Li Song; Ziqian Xu; Jie Zheng; Fabao Gao
Journal:  Korean J Radiol       Date:  2018-02-22       Impact factor: 3.500

4.  Sorted Golden-step phase encoding: an improved Golden-step imaging technique for cardiac and respiratory self-gated cine cardiovascular magnetic resonance imaging.

Authors:  Liheng Guo; Daniel A Herzka
Journal:  J Cardiovasc Magn Reson       Date:  2019-04-18       Impact factor: 5.364

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.