Literature DB >> 12541240

Undersampled projection reconstruction for active catheter imaging with adaptable temporal resolution and catheter-only views.

Dana C Peters1, Robert J Lederman, Alexander J Dick, Venkatesh K Raman, Michael A Guttman, J Andrew Derbyshire, Elliot R McVeigh.   

Abstract

In this study undersampled projection reconstruction (PR) was used for rapid catheter imaging in the heart, employing steady-state free precession (SSFP) contrast. Active catheters and phased-array coils were used for combined imaging of anatomy and catheter position in swine. Real-time imaging of catheter position was performed with relatively high spatial and temporal resolution, providing 2 x 2 x 8 mm spatial resolution and four to eight frames per second. Two interactive features were introduced. The number of projections (Np) was adjusted interactively to trade off imaging speed and artifact reduction, allowing acquisition of high-quality or high-frame-rate images. Thin-slice imaging was performed, with interactive requests for thick-slab projection images of the signal received solely from the active catheter. Briefly toggling on catheter-only projection images was valuable for verifying that the catheter tip was contained within the selected slice, or for locating the catheter when part of it was outside the selected slice.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12541240      PMCID: PMC2396305          DOI: 10.1002/mrm.10390

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  25 in total

1.  Toward MRI-guided coronary catheterization: visualization of guiding catheters, guidewires, and anatomy in real time.

Authors:  J M Serfaty; X Yang; P Aksit; H H Quick; M Solaiyappan; E Atalar
Journal:  J Magn Reson Imaging       Date:  2000-10       Impact factor: 4.813

2.  Techniques for fast stereoscopic MRI.

Authors:  M A Guttman; E R McVeigh
Journal:  Magn Reson Med       Date:  2001-08       Impact factor: 4.668

3.  Simultaneous acquisition of multiple resolution images for dynamic contrast enhanced imaging of the breast.

Authors:  H K Song; L Dougherty; M D Schnall
Journal:  Magn Reson Med       Date:  2001-09       Impact factor: 4.668

4.  A method for fast 3D tracking using tuned fiducial markers and a limited projection reconstruction FISP (LPR-FISP) sequence.

Authors:  C Flask; D Elgort; E Wong; A Shankaranarayanan; J Lewin; M Wendt; J L Duerk
Journal:  J Magn Reson Imaging       Date:  2001-11       Impact factor: 4.813

5.  Projection reconstruction balanced fast field echo for interactive real-time cardiac imaging.

Authors:  T Schaeffter; S Weiss; H Eggers; V Rasche
Journal:  Magn Reson Med       Date:  2001-12       Impact factor: 4.668

6.  Steps toward percutaneous aortic valve replacement.

Authors:  Younes Boudjemline; Philipp Bonhoeffer
Journal:  Circulation       Date:  2002-02-12       Impact factor: 29.690

7.  Projection reconstruction techniques for reduction of motion effects in MRI.

Authors:  G H Glover; J M Pauly
Journal:  Magn Reson Med       Date:  1992-12       Impact factor: 4.668

8.  Radial keyhole sequences for low field projection reconstruction interventional MRI.

Authors:  A Shankaranarayanan; M Wendt; A J Aschoff; J S Lewin; J L Duerk
Journal:  J Magn Reson Imaging       Date:  2001-01       Impact factor: 4.813

9.  Selection of a convolution function for Fourier inversion using gridding [computerised tomography application].

Authors:  J I Jackson; C H Meyer; D G Nishimura; A Macovski
Journal:  IEEE Trans Med Imaging       Date:  1991       Impact factor: 10.048

10.  Catheter-tracking FOV MR fluoroscopy.

Authors:  E Atalar; D L Kraitchman; B Carkhuff; J Lesho; O Ocali; M Solaiyappan; M A Guttman; H K Charles
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

View more
  15 in total

1.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

2.  Reduced field of view and undersampled PR combined for interventional imaging of a fully dynamic field of view.

Authors:  Dana C Peters; Michael A Guttman; Alexander J Dick; Venkatesh K Raman; Robert J Lederman; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

3.  Real-time magnetic resonance imaging to guide pediatric endovascular procedures.

Authors:  A N Raval; R J Lederman
Journal:  Pediatr Cardiol       Date:  2005 May-Jun       Impact factor: 1.655

Review 4.  13C imaging-a new diagnostic platform.

Authors:  Sven Månsson; Edvin Johansson; Peter Magnusson; Chun-Ming Chai; Georg Hansson; J Stefan Petersson; Freddy Ståhlberg; Klaes Golman
Journal:  Eur Radiol       Date:  2005-06-14       Impact factor: 5.315

5.  Real-time magnetic resonance-guided endovascular repair of experimental abdominal aortic aneurysm in swine.

Authors:  Venkatesh K Raman; Parag V Karmarkar; Michael A Guttman; Alexander J Dick; Dana C Peters; Cengizhan Ozturk; Breno S S Pessanha; Richard B Thompson; Amish N Raval; Ranil DeSilva; Ronnier J Aviles; Ergin Atalar; Elliot R McVeigh; Robert J Lederman
Journal:  J Am Coll Cardiol       Date:  2005-06-21       Impact factor: 24.094

6.  Interventional cardiovascular procedures guided by real-time MR imaging: an interactive interface using multiple slices, adaptive projection modes and live 3D renderings.

Authors:  Michael A Guttman; Cenghizhan Ozturk; Amish N Raval; Venkatesh K Raman; Alexander J Dick; Ranil DeSilva; Parag Karmarkar; Robert J Lederman; Elliot R McVeigh
Journal:  J Magn Reson Imaging       Date:  2007-12       Impact factor: 4.813

Review 7.  Stem cell therapy: MRI guidance and monitoring.

Authors:  Dara L Kraitchman; Wesley D Gilson; Christine H Lorenz
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

Review 8.  Magnetic Resonance Sequences and Rapid Acquisition for MR-Guided Interventions.

Authors:  Adrienne E Campbell-Washburn; Anthony Z Faranesh; Robert J Lederman; Michael S Hansen
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-08-12       Impact factor: 2.266

9.  Magnetic resonance fluoroscopy allows targeted delivery of mesenchymal stem cells to infarct borders in Swine.

Authors:  Alexander J Dick; Michael A Guttman; Venkatesh K Raman; Dana C Peters; Breno S S Pessanha; Jonathan M Hill; Scott Smith; Greig Scott; Elliot R McVeigh; Robert J Lederman
Journal:  Circulation       Date:  2003-12-01       Impact factor: 29.690

Review 10.  Cardiovascular magnetic resonance guided electrophysiology studies.

Authors:  Aravindan Kolandaivelu; Albert C Lardo; Henry R Halperin
Journal:  J Cardiovasc Magn Reson       Date:  2009-07-06       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.