Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results.

Stefanie Weigel1, Bernd Tombach, David Maintz, Stefan Klotz, Thomas Vestring, Walter Heindel, Roman Fischbach.   

Abstract

The objective of this study was to compare contrast-enhanced magnetic resonance angiography (CE MRA) and multislice computed tomographic angiography (MS CTA) in the follow-up of thoracic stent-graft placement. The CE MRA and MS CTA were performed following nitinol stent-graft treatment due to thoracic aneurysm ( n=4), intramural bleeding ( n=2) and type-B aortic dissection ( n=5). Corresponding evaluation of arterial-phase imaging characteristics focused on the stent-graft morphology and leakage assessment. Stent-graft and aneurysm extensions were comparable between both techniques. Complete exclusion (aneurysm, n=4; dissection, n=2) was assessed with high confidence with CE MRA and MS CTA. Incomplete exclusion (intramural bleeding, n=2; dissection, n=3) was assigned to lower confidence scores on CE MRA compared with MS CTA. On CE MRA the stent-graft lumen demonstrated an inhomogeneous signal, the stent struts could not be assessed. The CE MRA can be used as alternative non-invasive imaging for follow-up of nitinol stent grafts. Arterial-phase leak assessment can be less evident in CE MRA compared with MS CTA studies; therefore, the use of late-phase imaging seems to be necessary. The diagnostic gap of stent-graft fracture evaluation using MRA may be filled with plain radiographs.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12835978     DOI: 10.1007/s00330-003-1832-9

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  18 in total

1.  Descending thoracic aortic aneurysm: thoracic CT findings after endovascular stent-graft placement.

Authors:  T Sakai; M D Dake; C P Semba; T Yamada; A Arakawa; S T Kee; N Hayashi; M K Razavi; D Y Sze
Journal:  Radiology       Date:  1999-07       Impact factor: 11.105

2.  Three-dimensional MR angiography of a nitinol-based abdominal aortic stent graft: assessment of heating and imaging characteristics.

Authors:  P R Hilfiker; H H Quick; T Pfammatter; M Schmidt; J F Debatin
Journal:  Eur Radiol       Date:  1999       Impact factor: 5.315

Review 3.  Endovascular treatment of thoracic aortic aneurysms: a review.

Authors:  Siegfried A Thurnher; Martin Grabenwöger
Journal:  Eur Radiol       Date:  2002-03-20       Impact factor: 5.315

4.  Stent appearance at contrast-enhanced MR angiography: in vitro examination with 14 stents.

Authors:  M Lenhart; M Völk; C Manke; W R Nitz; M Strotzer; S Feuerbach; J Link
Journal:  Radiology       Date:  2000-10       Impact factor: 11.105

5.  Magnetic resonance imaging and MR angiography of endoluminally treated abdominal aortic aneurysms.

Authors:  L Engellau; E M Larsson; U Albrechtsson; T Jonung; E Ribbe; J Thörne; Z Zdanowski; L Norgren
Journal:  Eur J Vasc Endovasc Surg       Date:  1998-03       Impact factor: 7.069

6.  Thoracic aortic aneurysms: treatment with endovascular self-expandable stent grafts.

Authors:  M Grabenwöger; D Hutschala; M P Ehrlich; F Cartes-Zumelzu; S Thurnher; J Lammer; E Wolner; M Havel
Journal:  Ann Thorac Surg       Date:  2000-02       Impact factor: 4.330

7.  CT-angiography of abdominal aortic aneurysms after transfemoral endovascular aneurysm management.

Authors:  R Balm; R Kaatee; J D Blankensteijn; W P Mali; B C Eikelboom
Journal:  Eur J Vasc Endovasc Surg       Date:  1996-08       Impact factor: 7.069

8.  Nonsurgical reconstruction of thoracic aortic dissection by stent-graft placement.

Authors:  C A Nienaber; R Fattori; G Lund; C Dieckmann; W Wolf; Y von Kodolitsch; V Nicolas; A Pierangeli
Journal:  N Engl J Med       Date:  1999-05-20       Impact factor: 91.245

9.  Endoluminal grafting of abdominal aortic aneurysms: experience with the Talent endoluminal stent graft.

Authors:  A Chavan; T U Cohnert; J Heine; C Dresler; M Leuwer; W Harringer; M Jörgensen; A Haverich; M Galanski
Journal:  Eur Radiol       Date:  2000       Impact factor: 5.315

10.  Traumatic thoracic aortic aneurysm: treatment with endovascular stent-grafts.

Authors:  N Kato; M D Dake; D C Miller; C P Semba; R S Mitchell; M K Razavi; S T Kee
Journal:  Radiology       Date:  1997-12       Impact factor: 11.105

View more
  8 in total

1.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  Circulation       Date:  2010-05-17       Impact factor: 29.690

Review 2.  ACCF/ACR/AHA/NASCI/SCMR 2010 expert consensus document on cardiovascular magnetic resonance: a report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents.

Authors:  W Gregory Hundley; David A Bluemke; J Paul Finn; Scott D Flamm; Mark A Fogel; Matthias G Friedrich; Vincent B Ho; Michael Jerosch-Herold; Christopher M Kramer; Warren J Manning; Manesh Patel; Gerald M Pohost; Arthur E Stillman; Richard D White; Pamela K Woodard
Journal:  J Am Coll Cardiol       Date:  2010-06-08       Impact factor: 24.094

3.  Placement of endovascular stent-grafts for emergency repair of acute traumatic aortic rupture: a single-centre experience.

Authors:  I E Steingruber; B V Czermak; A Chemelli; B Glodny; J Bonatti; W Jaschke; P Waldenberger; M Rieger; B Neuhauser
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

4.  Assessment of thoracic aortic conformational changes by four-dimensional computed tomography angiography in patients with chronic aortic dissection type b.

Authors:  Tim F Weber; Maria-Katharina Ganten; Dittmar Böckler; Philipp Geisbüsch; Annette Kopp-Schneider; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Eur Radiol       Date:  2008-07-22       Impact factor: 5.315

Review 5.  Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

Authors:  Evridiki Karanikola; Ilias Dalainas; Georgios Karaolanis; Georgios Zografos; Konstantinos Filis
Journal:  Int J Angiol       Date:  2014-09

6.  MRI assessment of thoracic stent grafts after emergency implantation in multi trauma patients: a feasibility study.

Authors:  Volker Rasche; Alexander Oberhuber; Stephan Trumpp; Axel Bornstedt; Karl-Heinz Orend; Nico Merkle; Wolfgang Rottbauer; Martin Hoffmann
Journal:  Eur Radiol       Date:  2011-02-18       Impact factor: 5.315

7.  Abdominal aortic aneurysm follow-up by shear wave elasticity imaging after endovascular repair in a canine model.

Authors:  Antony Bertrand-Grenier; Sophie Lerouge; An Tang; Eli Salloum; Eric Therasse; Claude Kauffmann; Hélène Héon; Igor Salazkin; Guy Cloutier; Gilles Soulez
Journal:  Eur Radiol       Date:  2016-08-29       Impact factor: 5.315

8.  Shear wave elasticity imaging for residual endoleak and thrombus characterisation after endoleak embolisation following endovascular aneurysm repair: a canine animal study.

Authors:  Antony Bertrand-Grenier; Fatemeh Zehtabi; Sophie Lerouge; Husain Alturkistani; Claude Kauffmann; Paule Bodson-Clermont; Igor Salazkin; Hélène Héon; Guy Cloutier; Gilles Soulez
Journal:  Eur Radiol Exp       Date:  2018-10-10
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.