Literature DB >> 10735678

Thoracic aortic aneurysms: treatment with endovascular self-expandable stent grafts.

M Grabenwöger1, D Hutschala, M P Ehrlich, F Cartes-Zumelzu, S Thurnher, J Lammer, E Wolner, M Havel.   

Abstract

BACKGROUND: This study was performed to evaluate the safety and feasibility of endovascular stent graft placement in the treatment of descending thoracic aortic aneurysms.
METHODS: Between November 1996 and February 1999, endovascular stent graft repair was used in 21 patients. There were 5 women and 16 men with a mean age of 67 years (range, 41 to 87 years). An atherosclerotic aneurysm with a diameter of more than 6 cm was the indication for intervention in 19 patients (90.5%). In 2 patients (9.5%), a localized aortic dissection with a diameter of more than 6 cm was treated. In 71.4% (15 of 21) of patients, multiple stents were necessary for aneurysm exclusion. To allow safe deployment of the stent graft, preliminary subclavian-carotid artery transposition was performed in 9 patients (42.9%). Vascular access was achieved through a small incision in the abdominal aorta (n = 6), an iliac artery (n = 8), or a femoral artery (n = 7). Talent and Prograft stent grafts were used.
RESULTS: Successful deployment of the endovascular stent grafts was achieved in all patients. Two patients died postoperatively (mortality rate, 9.5%), 1 of aneurysmal rupture and the other of impaired perfusion of the celiac axis. Repeat stenting was done in 3 patients because of intraoperative leakage.
CONCLUSIONS: Endovascular stent graft repair is a promising and less invasive alternative to exclude the aneurysm from blood flow. This technique allows treatment of patients who are unsuitable for conventional surgical procedures. An exact definition of inclusion criteria and technical development of stent grafts should contribute to further improvements in clinical results.

Entities:  

Mesh:

Year:  2000        PMID: 10735678     DOI: 10.1016/s0003-4975(99)01291-6

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  11 in total

1.  A case of paraplegia following endovascular stent repair of descending thoracic aortic aneurysm.

Authors:  Min Young Lee; Myung-Goo Lee; Kyung-Soon Hong; Chang Yul Lee; Kyu Tae Park; Chan Woo Lee; Myeong Shin Ryu; Young Muk Kim; Dae Hyun Hwang
Journal:  Korean Circ J       Date:  2011-03-31       Impact factor: 3.243

2.  Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results.

Authors:  Stefanie Weigel; Bernd Tombach; David Maintz; Stefan Klotz; Thomas Vestring; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

3.  Long-term results of endoluminal grafting for descending thoracic aortic aneurysms.

Authors:  Hirofumi Midorikawa; Tomohiro Ogawa; Kouichi Satou; Shunichi Hoshino; Shinya Takase; Hitoshi Yokoyama
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2005-06

4.  Endovascular repair in management of thoracic aortic aneurysms.

Authors:  Hakan Bingol; Hikmet Iyem; Hakki Tankut Akay; Bahri Ustunsoz; Cengiz Bolcal; Sahin Ugurer; Gokce Sirin; Ufuk Demirkilic; Harun Tatar
Journal:  Int J Cardiovasc Imaging       Date:  2006-06-29       Impact factor: 2.357

5.  Urgent thoracic aortal dissection and aneurysm: treatment with stent-graft implantation in an angiographic suite.

Authors:  Jörn O Balzer; Mirko Doss; Axel Thalhammer; Hans-Gerd Fieguth; Anton Moritz; Thomas J Vogl
Journal:  Eur Radiol       Date:  2003-05-14       Impact factor: 5.315

6.  Management strategies for thoracic stent-graft repair of distal aortic arch lesions: is intentional subclavian artery occlusion a safe procedure?

Authors:  Fabrizio Fanelli; Michael D Dake; Filippo Maria Salvatori; Armando Pucci; Giuseppe Mazzesi; Pierleone Lucatelli; Plinio Rossi; Roberto Passariello
Journal:  Eur Radiol       Date:  2009-05-09       Impact factor: 5.315

7.  Comprehensive assessment of mechanical behavior of an extremely long stent graft to control hemorrhage in torso.

Authors:  Moataz Elsisy; Bryan W Tillman; Catherine Go; Jenna Kuhn; Sung K Cho; William W Clark; Junkyu Park; Youngjae Chun
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-01-14       Impact factor: 3.368

8.  Endovascular repair of thoracic aortic aneurysm.

Authors:  Ibrahim Akin; Stephan Kische; Tim C Rehders; Christoph A Nienaber; Mathias Rauchhaus; Hüseyin Ince
Journal:  Arch Med Sci       Date:  2010-10-26       Impact factor: 3.318

9.  Rescue Technique for Malposition Caused by Mislabeled Stent Graft in Thoracic Aneurysm.

Authors:  Hyuk Jae Jung; Bong Soo Son; Do Hyung Kim; Sang Su Lee
Journal:  Vasc Specialist Int       Date:  2017-12-31

Review 10.  Demystifying penetrating atherosclerotic ulcer of aorta: unrealised tyrant of senile aortic changes.

Authors:  Rahul Dev; Khorwal Gitanjali; Darbari Anshuman
Journal:  J Cardiovasc Thorac Res       Date:  2021-01-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.