Literature DB >> 10405738

Descending thoracic aortic aneurysm: thoracic CT findings after endovascular stent-graft placement.

T Sakai1, M D Dake, C P Semba, T Yamada, A Arakawa, S T Kee, N Hayashi, M K Razavi, D Y Sze.   

Abstract

PURPOSE: To evaluate the usefulness of thoracic computed tomography (CT) after placement of an endovascular stent-graft for the treatment of descending thoracic aortic aneurysm.
MATERIALS AND METHODS: From 1992 to 1996, 85 patients with thoracic aortic aneurysm underwent stent-graft placement. In 63 patients, thoracic CT scans were obtained both before and within 10 days after placement. The CT findings were retrospectively studied, and their clinical effect analyzed. In 20 of 63 patients, long-term follow-up CT findings were also evaluated.
RESULTS: After stent-graft placement in the 63 patients, CT demonstrated an increase in pleural effusion in 46 (73%), periaortic changes in 21 (33%), perigraft leak in 13 (21%), atelectasis in six (10%), mural thrombus within the stent-graft in two (3%), and new aortic dissection in one (2%). The mean maximum diameter of the aneurysm was 58.8 mm before and 60.0 mm after stent-graft insertion. Sixty-two (98%) patients were successfully treated until discharge. Interventional procedures were performed to eliminate the leakage into the aneurysm sac in 10 patients with perigraft flow depicted at CT. Other complications were managed conservatively.
CONCLUSION: Thoracic CT is useful in the treatment of patients after stent-graft insertion for the management of descending thoracic aortic aneurysm.

Entities:  

Mesh:

Year:  1999        PMID: 10405738     DOI: 10.1148/radiology.212.1.r99jl37169

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  5 in total

1.  Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results.

Authors:  Stefanie Weigel; Bernd Tombach; David Maintz; Stefan Klotz; Thomas Vestring; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

2.  Unusual complications of endovascular repair of the thoracic aorta: MDCT findings.

Authors:  T Valente; G Rossi; F Lassandro; G Rea; M Marino; G Dialetto; R Muto; M Scaglione
Journal:  Radiol Med       Date:  2012-01-07       Impact factor: 3.469

Review 3.  TEVAR: Endovascular Repair of the Thoracic Aorta.

Authors:  David A Nation; Grace J Wang
Journal:  Semin Intervent Radiol       Date:  2015-09       Impact factor: 1.513

4.  Endovascular repair of the thoracic aorta.

Authors:  Grace J Wang; Ronald M Fairman
Journal:  Semin Intervent Radiol       Date:  2009-03       Impact factor: 1.513

5.  Role of multidetector computed tomography in evaluating complications following endovascular repair of aortic aneurysm.

Authors:  Zarina Abdul Aziz; Purushotham R Naidu; Jagadish Prasad; Arjun Kalyanpur
Journal:  J Cardiovasc Dis Res       Date:  2010-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.