Literature DB >> 8760980

CT-angiography of abdominal aortic aneurysms after transfemoral endovascular aneurysm management.

R Balm1, R Kaatee, J D Blankensteijn, W P Mali, B C Eikelboom.   

Abstract

OBJECTIVE: To evaluate short-term effect of Transfemoral Endovascular Aneurysm Management (TEAM) on aortic diameters and volumes after aneurysm exclusion, using CT-angiography.
DESIGN: Analysis of preoperative, 1 week postoperative and 6 months postoperative CT measurements.
SETTING: University Hospital. MATERIALS: Nine patients treated with an endovascular tube prosthesis. CHIEF OUTCOME MEASURES: True cross-sectional diameters of the aorta and the aneurysm, volume of the infrarenal aortic lumen, of the thrombus and of the iliac arteries and length of the aorta and of the endovascular prosthesis. MAIN
RESULTS: CT-angiography detected shrinkage of the aneurysm in seven patients. Aneurysm growth was observed in one patient with persistent flow outside the graft and in one patient with fully thrombosed aneurysm sac. In the two patients with increasing thrombus volume, the volume of the aortic lumen decreased.
CONCLUSIONS: Although successful aneurysm exclusion can be confirmed by maximum aneurysm diameter measurement, changes in aortic lumen volume and thrombus volume may be more appropriate to discriminate successful from failed exclusion.

Entities:  

Mesh:

Year:  1996        PMID: 8760980     DOI: 10.1016/s1078-5884(96)80104-3

Source DB:  PubMed          Journal:  Eur J Vasc Endovasc Surg        ISSN: 1078-5884            Impact factor:   7.069


  4 in total

1.  Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results.

Authors:  Stefanie Weigel; Bernd Tombach; David Maintz; Stefan Klotz; Thomas Vestring; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

2.  Use of spiral computed tomographic angiography in monitoring abdominal aortic aneurysms after transfemoral endovascular repair.

Authors:  R Balm; M J Jacobs
Journal:  Tex Heart Inst J       Date:  1997

Review 3.  Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

Authors:  Evridiki Karanikola; Ilias Dalainas; Georgios Karaolanis; Georgios Zografos; Konstantinos Filis
Journal:  Int J Angiol       Date:  2014-09

4.  A multidetector tomography protocol for follow-up of endovascular aortic aneurysm repair.

Authors:  Roberto Moraes Bastos; Alvaro Razuk Filho; Roberto Blasbalg; Roberto Augusto Caffaro; Walter Khegan Karakhanian; Antonio José Rocha
Journal:  Clinics (Sao Paulo)       Date:  2011       Impact factor: 2.365

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.