Literature DB >> 10795547

Endoluminal grafting of abdominal aortic aneurysms: experience with the Talent endoluminal stent graft.

A Chavan1, T U Cohnert, J Heine, C Dresler, M Leuwer, W Harringer, M Jörgensen, A Haverich, M Galanski.   

Abstract

The aim of this study was to evaluate the Talent endoluminal stent graft (TESG) in treating abdominal aortic aneurysms (AAA). The TESG is a polyester-covered nitinol endograft (proximal diameters 20-38 mm and iliac limb diameters 8-22 mm). Twenty-two men were treated with the TESG via bilateral femoral arteriotomies. Pre-implantation, coil embolization of various vessels arising from the aneurysm was performed in 6 patients. Plain radiographs and spiral CT angiograms (CTA) were carried out at 7 days, 3, 6, and 12 months following TESG implantation or re-intervention. Median aortic and iliac diameters were 27 mm (range 20-34 mm) and 14 mm (range 10-19 mm). The corresponding graft diameters were 30 mm (range 24-38 mm) and 14 mm (range 12-20 mm). No patient was rejected purely on the basis of too large aortic or iliac diameters. Eight patients required custom-made grafts. Graft implantation was successful in all patients. There were no blood transfusions, distal embolic episodes, or conversions to open surgery. Re-intervention was necessary in 1 patient. Complications included one fatal myocardial infarction, one inguinal hematoma, and two superficial wound infections. The aneurysm thrombosed completely following implantation in 14 patients and at 3 or 6 months in 4 other patients. One patient with endoleak is awaiting his 3-month control and 2 patients show tiny endoleaks but reduction of aneurysm size. The mean aneurysm size decreased significantly from 58 +/- 10 to 53 +/- 13 mm (p < 0.0005). Due to the large sizes available and the option of custom-made grafts, the TESG helps widen the spectrum of patients who can be treated with endoluminal grafting. The treatment is associated with a significant reduction in aneurysm size.

Entities:  

Mesh:

Year:  2000        PMID: 10795547     DOI: 10.1007/s003300050976

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  1 in total

1.  Thoracic aortic stent graft: comparison of contrast-enhanced MR angiography and CT angiography in the follow-up: initial results.

Authors:  Stefanie Weigel; Bernd Tombach; David Maintz; Stefan Klotz; Thomas Vestring; Walter Heindel; Roman Fischbach
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.