Literature DB >> 25317026

Duplex Ultrasound versus Computed Tomography for the Postoperative Follow-Up of Endovascular Abdominal Aortic Aneurysm Repair. Where Do We Stand Now?

Evridiki Karanikola1, Ilias Dalainas2, Georgios Karaolanis3, Georgios Zografos1, Konstantinos Filis1.   

Abstract

In the last decade, endovascular aneurysm repair (EVAR) has rapidly developed to be the preferred method for infrarenal abdominal aortic aneurysm repair in patients with suitable anatomy. EVAR offers the advantage of lower perioperative mortality and morbidity but carries the cost of device-related complications such as endoleak, graft migration, graft thrombosis, and structural graft failure. These complications mandate a lifelong surveillance of EVAR patients and their endografts. The purpose of this study is to review and evaluate the safety of color-duplex ultrasound (CDU) as compared with computed tomography (CT), based on the current literature, for post-EVAR surveillance. The post-EVAR follow-up modalities, CDU versus CT, are evaluated questioning three parameters: (1) accuracy of aneurysm size, (2) detection and classification of endoleaks, and (3) detection of stent-graft deformation. Studies comparing CDU with CT scan for investigation of post-EVAR complications have produced mixed results. Further and long-term research is needed to evaluate the efficacy of CDU versus CT, before CDU can be recommended as the primary imaging modality for EVAR surveillance, in place of CT for stable aneurysms.

Entities:  

Keywords:  CDU vs CT; EVAR surveillance; post-EVAR follow-up

Year:  2014        PMID: 25317026      PMCID: PMC4169100          DOI: 10.1055/s-0034-1387925

Source DB:  PubMed          Journal:  Int J Angiol        ISSN: 1061-1711


  88 in total

1.  Hospital costs for elective endovascular and surgical repairs of infrarenal abdominal aortic aneurysms.

Authors:  J L Bosch; J S Lester; P M McMahon; M T Beinfeld; E F Halpern; J A Kaufman; D C Brewster; G S Gazelle
Journal:  Radiology       Date:  2001-08       Impact factor: 11.105

Review 2.  Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review.

Authors:  Roy Ashoke; Louise C Brown; Alex Rodway; Edward Choke; Matthew M Thompson; Roger M Greenhalgh; Janet T Powell
Journal:  J Endovasc Ther       Date:  2005-06       Impact factor: 3.487

3.  Contrast-enhanced ultrasound versus computed tomographic angiography for surveillance of endovascular abdominal aortic aneurysm repair.

Authors:  Jan A Ten Bosch; Ellen V Rouwet; Cecile T H Peters; Linda Jansen; Hence J M Verhagen; Martin H Prins; Joep A W Teijink
Journal:  J Vasc Interv Radiol       Date:  2010-04-02       Impact factor: 3.464

4.  Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience. European Collaborators on Stent/graft techniques for aortic aneurysm repair.

Authors:  P L Harris; S R Vallabhaneni; P Desgranges; J P Becquemin; C van Marrewijk; R J Laheij
Journal:  J Vasc Surg       Date:  2000-10       Impact factor: 4.268

5.  Defining a role for contrast-enhanced ultrasound in endovascular aneurysm repair surveillance.

Authors:  Alistair Millen; Rana Canavati; Gareth Harrison; Richard G McWilliams; Steve Wallace; Srinivasa R Vallabhaneni; Robert K Fisher
Journal:  J Vasc Surg       Date:  2013-03-13       Impact factor: 4.268

Review 6.  Estimating risk associated with radiation exposure during follow-up after endovascular aortic repair (EVAR).

Authors:  H A White; S Macdonald
Journal:  J Cardiovasc Surg (Torino)       Date:  2010-02       Impact factor: 1.888

7.  Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography.

Authors:  Brian J Manning; Sean M O'Neill; Syed N Haider; Mary P Colgan; Prakash Madhavan; Dermot J Moore
Journal:  J Vasc Surg       Date:  2008-10-01       Impact factor: 4.268

Review 8.  The use of color-flow duplex scan for the detection of endoleaks.

Authors:  Robert B McLafferty; Bradford S McCrary; Mark A Mattos; Laura A Karch; Don E Ramsey; Maurice M Solis; Kim J Hodgson
Journal:  J Vasc Surg       Date:  2002-07       Impact factor: 4.268

9.  Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: a cost analysis study and prospective comparison with computed tomography scan.

Authors:  Brian R Beeman; Lynne M Doctor; Kevin Doerr; Sandy McAfee-Bennett; Matthew J Dougherty; Keith D Calligaro
Journal:  J Vasc Surg       Date:  2009-08-05       Impact factor: 4.268

10.  What is the clinical utility of a 6-month computed tomography in the follow-up of endovascular aneurysm repair patients?

Authors:  Michael R Go; Joel E Barbato; Robert Y Rhee; Michel S Makaroun
Journal:  J Vasc Surg       Date:  2008-06       Impact factor: 4.268

View more
  2 in total

Review 1.  Colour Duplex and/or Contrast-Enhanced Ultrasound Compared with Computed Tomography Angiography for Endoleak Detection after Endovascular Abdominal Aortic Aneurysm Repair: A Systematic Review and Meta-Analysis.

Authors:  Georgios I Karaolanis; Constantine N Antonopoulos; Efstratios Georgakarakos; Georgios D Lianos; Michail Mitsis; Georgios K Glantzounis; Athanasios Giannoukas; George Kouvelos
Journal:  J Clin Med       Date:  2022-06-23       Impact factor: 4.964

Review 2.  Imaging modalities for endoleak surveillance.

Authors:  Aman Berry Williams; Zoheb Berry Williams
Journal:  J Med Radiat Sci       Date:  2021-06-18