The volume effect of detectors in the dosimetry of small fields used in IMRT.

Wolfram U Laub1, Tony Wong.   

Abstract

In this study we investigate the effect of detector size in the dosimetry of small fields and steep dose gradients with a particular emphasis on IMRT measurements. Comparisons of calculated and measured cross-profiles and absolute dose values of IMRT treatment plans are presented. As a consequence of the finite size of the detector that was used for the commissioning of the IMRT tool, local discrepancies of more than 10% are found between calculated cross-profiles of intensity modulated beams and intensity modulated profiles measured with film. Absolute dose measurements of intensity modulated fields with a 0.6 cm3 Farmer chamber show significant differences of more than 6% between calculated and measured dose values at the isocenter of an IMRT treatment plan. Differences of not more than 2% are found in the same experiment for dose values measured with a 0.015 cm3 pinpoint ion chamber. A method to correct for the spatial response of finite-sized detectors and to obtain the "real" penumbra width of cross-profiles from measurements is introduced. Output factor measurements are performed with different detectors and are presented as a function of detector size for a 1 x 1 cm2 field. Because of its high spatial resolution and water equivalence, a diamond detector is found to be suitable as an alternative to other detectors used for small field dosimetry as there are photographic and photochromic film, TLDs, or water-equivalent scintillation detectors.

Entities:  

Mesh:

Year:  2003        PMID: 12674234     DOI: 10.1118/1.1544678

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  34 in total

1.  PRESAGE 3D dosimetry accurately measures Gamma Knife output factors.

Authors:  Slade J Klawikowski; James N Yang; John Adamovics; Geoffrey S Ibbott
Journal:  Phys Med Biol       Date:  2014-11-04       Impact factor: 3.609

2.  Measuring output factors of small fields formed by collimator jaws and multileaf collimator using plastic scintillation detectors.

Authors:  David M Klein; Ramesh C Tailor; Louis Archambault; Lilie Wang; Francois Therriault-Proulx; A Sam Beddar
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

3.  The change of response of ionization chambers in the penumbra and transmission regions: impact for IMRT verification.

Authors:  D González-Castaño; J Pena; F Sánchez-Doblado; G H Hartmann; F Gómez; A Leal
Journal:  Med Biol Eng Comput       Date:  2007-09-08       Impact factor: 2.602

4.  Total scatter factors of small beams: a multidetector and Monte Carlo study.

Authors:  Paolo Francescon; Stefania Cora; Carlo Cavedon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

5.  Monte Carlo simulations applied to conjunctival lymphoma radiotherapy treatment.

Authors:  Lorenzo Brualla; Ricardo Palanco-Zamora; Klaus-Peter Steuhl; Norbert Bornfeld; Wolfgang Sauerwein
Journal:  Strahlenther Onkol       Date:  2011-07-25       Impact factor: 3.621

6.  Investigating the Electronic Portal Imaging Device for Small Radiation Field Measurements.

Authors:  Arpita Agarwal; Nikhil Rastogi; K J Maria Das; S A Yoganathan; D Udayakumar; Shaleen Kumar
Journal:  J Med Phys       Date:  2017 Apr-Jun

7.  Dosimetric characterization and behaviour in small X-ray fields of a microchamber and a plastic scintillator detector.

Authors:  Massimo Pasquino; Claudia Cutaia; Lorenzo Radici; Serena Valzano; Eva Gino; Carlo Cavedon; Michele Stasi
Journal:  Br J Radiol       Date:  2016-11-09       Impact factor: 3.039

8.  Optical imaging provides rapid verification of static small beams, radiosurgery, and VMAT plans with millimeter resolution.

Authors:  Muhammad Ramish Ashraf; Petr Bruza; Brian W Pogue; Nathan Nelson; Benjamin B Williams; Lesley A Jarvis; David J Gladstone
Journal:  Med Phys       Date:  2019-10-04       Impact factor: 4.071

9.  Commissioning of a novel microCT/RT system for small animal conformal radiotherapy.

Authors:  Manuel Rodriguez; Hu Zhou; Paul Keall; Edward Graves
Journal:  Phys Med Biol       Date:  2009-05-28       Impact factor: 3.609

10.  In-phantom dose verification of prostate IMRT and VMAT deliveries using plastic scintillation detectors.

Authors:  David Klein; Tina Marie Briere; Rajat Kudchadker; Louis Archambault; Luc Beaulieu; Andrew Lee; Sam Beddar
Journal:  Radiat Meas       Date:  2012-08-24       Impact factor: 1.898

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.