PRESAGE 3D dosimetry accurately measures Gamma Knife output factors.

Slade J Klawikowski1, James N Yang, John Adamovics, Geoffrey S Ibbott.   

Abstract

Small-field output factor measurements are traditionally very difficult because of steep dose gradients, loss of lateral electronic equilibrium, and dose volume averaging in finitely sized detectors. Three-dimensional (3D) dosimetry is ideal for measuring small output factors and avoids many of these potential challenges of point and 2D detectors. PRESAGE 3D polymer dosimeters were used to measure the output factors for the 4 mm and 8 mm collimators of the Leksell Perfexion Gamma Knife radiosurgery treatment system. Discrepancies between the planned and measured distance between shot centers were also investigated. A Gamma Knife head frame was mounted onto an anthropomorphic head phantom. Special inserts were machined to hold 60 mm diameter, 70 mm tall cylindrical PRESAGE dosimeters. The phantom was irradiated with one 16 mm shot and either one 4 mm or one 8 mm shot, to a prescribed dose of either 3 Gy or 4 Gy to the 50% isodose line. The two shots were spaced between 30 mm and 60 mm apart and aligned along the central axis of the cylinder. The Presage dosimeters were measured using the DMOS-RPC optical CT scanning system. Five independent 4 mm output factor measurements fell within 2% of the manufacturer's Monte Carlo simulation-derived nominal value, as did two independent 8 mm output factor measurements. The measured distances between shot centers varied by ± 0.8 mm with respect to the planned shot displacements. On the basis of these results, we conclude that PRESAGE dosimetry is excellently suited to quantify the difficult-to-measure Gamma Knife output factors.

Entities:  

Mesh:

Year:  2014        PMID: 25368961      PMCID: PMC4285621          DOI: 10.1088/0031-9155/59/23/N211

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  The volume effect of detectors in the dosimetry of small fields used in IMRT.

Authors:  Wolfram U Laub; Tony Wong
Journal:  Med Phys       Date:  2003-03       Impact factor: 4.071

2.  Commissioning a small-field biological irradiator using point, 2D, and 3D dosimetry techniques.

Authors:  Joseph Newton; Mark Oldham; Andrew Thomas; Yifan Li; John Adamovics; David G Kirsch; Shiva Das
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

3.  Preliminary commissioning investigations with the DMOS-RPC optical-CT Scanner.

Authors:  J Newton; A Thomas; G Ibbott; M Oldham
Journal:  J Phys Conf Ser       Date:  2010

4.  Characterization of a new radiochromic three-dimensional dosimeter.

Authors:  P Y Guo; J A Adamovics; M Oldham
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

5.  A practical three-dimensional dosimetry system for radiation therapy.

Authors:  Pengyi Guo; John Adamovics; Mark Oldham
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

6.  Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation.

Authors:  H S Sakhalkar; M Oldham
Journal:  Med Phys       Date:  2008-01       Impact factor: 4.071

7.  A simple and effective method for validation and measurement of collimator output factors for Leksell Gamma Knife Perfexion.

Authors:  Lijun Ma; Per Kjäll; Josef Novotny; Håkan Nordström; Jonas Johansson; Lynn Verhey
Journal:  Phys Med Biol       Date:  2009-06-02       Impact factor: 3.609

8.  Characterization of the optical properties and stability of Presage™ following irradiation with photons and carbon ions.

Authors:  Esben S Yates; Peter Balling; Jørgen B B Petersen; Mehrnaz N Christensen; Peter S Skyt; Niels Bassler; Franz-Joachim Kaiser; Ludvig P Muren
Journal:  Acta Oncol       Date:  2011-08       Impact factor: 4.089

9.  Toward acquiring comprehensive radiosurgery field commissioning data using the PRESAGE/optical-CT 3D dosimetry system.

Authors:  Corey Clift; Andrew Thomas; John Adamovics; Zheng Chang; Indra Das; Mark Oldham
Journal:  Phys Med Biol       Date:  2010-02-04       Impact factor: 3.609

10.  Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry.

Authors:  Timothy Olding; Oliver Holmes; Paul Dejean; Kim B McAuley; Ken Nkongchu; Giles Santyr; L John Schreiner
Journal:  J Med Phys       Date:  2011-01
View more
  4 in total

1.  Output factor comparison of Monte Carlo and measurement for Varian TrueBeam 6 MV and 10 MV flattening filter-free stereotactic radiosurgery system.

Authors:  Jason Y Cheng; Holly Ning; Barbara C Arora; Ying Zhuge; Robert W Miller
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

2.  Dosimetric characterization of a body-conforming radiochromic sheet.

Authors:  Yi-Fang Wang; Olga Dona; Kevin Liu; John Adamovics; Cheng-Shie Wuu
Journal:  J Appl Clin Med Phys       Date:  2020-02-26       Impact factor: 2.102

Review 3.  A Review of PRESAGE Radiochromic Polymer and the Compositions for Application in Radiotherapy Dosimetry.

Authors:  Muhammad Zamir Mohyedin; Hafiz Mohd Zin; Mohd Zulfadli Adenan; Ahmad Taufek Abdul Rahman
Journal:  Polymers (Basel)       Date:  2022-07-16       Impact factor: 4.967

Review 4.  Radiation Dosimetry by Use of Radiosensitive Hydrogels and Polymers: Mechanisms, State-of-the-Art and Perspective from 3D to 4D.

Authors:  Yves De Deene
Journal:  Gels       Date:  2022-09-19
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.