Literature DB >> 16977442

Multi-detector row CT of the head and neck: comparison of different volumes of contrast material with and without a saline chaser.

Dae Young Yoon1, Su Yeon You, Chul Soon Choi, Suk Ki Chang, Eun Joo Yun, Young Lan Seo, Sang Joon Park, Yu-Jin Lee, Jeung Hee Moon, Young-Soo Rho, Jin-Hwan Kim.   

Abstract

INTRODUCTION: The aim of this study was to determine the effect of different volumes of contrast material with and without a saline chaser on tissue enhancement in multidetector row CT (MDCT) of the head and neck.
METHODS: In a blind prospective fashion, 120 patients were randomized into the following four groups: group 1, 80 ml contrast material administered at a flow rate of 2.0 ml/s; group 2, 80 ml followed by 40 ml saline at 2.0 ml/s; group 3, 60 ml at 1.5 ml/s; and group 4, 60 ml followed by 30 ml saline at 1.5 ml/s. The attenuation values of the carotid artery, internal jugular vein, and muscle were measured at an interval of 1.5 s in each patient. The degree of perivenous artifacts was subjectively assessed.
RESULTS: Mean attenuation values in the carotid artery and internal jugular vein were significantly higher in groups 1 and 2 than in groups 3 and 4. The width of the diagnostic window (both carotid and jugular enhancement >150 HU) were significantly longer in groups 1 and 2 than in groups 3 and 4. The addition of a saline chaser did not result in improved vascular enhancement or a wider diagnostic window, but reduced perivenous artifacts, compared with using contrast material alone.
CONCLUSION: Reduction of contrast material from 80 to 60 ml results in insufficient enhancement of neck vessels. In addition, the benefit of a saline chaser technique is not obvious except for its ability to reduce perivenous artifacts.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16977442     DOI: 10.1007/s00234-006-0146-4

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  25 in total

1.  Aortoiliac enhancement during computed tomography angiography with reduced contrast material dose and saline solution flush: influence on magnitude and uniformity of the contrast column.

Authors:  Helmut Schoellnast; Manfred Tillich; Michael J Deutschmann; Hannes A Deutschmann; Gottfried J Schaffler; Horst R Portugaller
Journal:  Invest Radiol       Date:  2004-01       Impact factor: 6.016

Review 2.  Parameters affecting bolus geometry in CTA: a review.

Authors:  Filippo Cademartiri; Aad van der Lugt; Giacomo Luccichenti; Paolo Pavone; Gabriel P Krestin
Journal:  J Comput Assist Tomogr       Date:  2002 Jul-Aug       Impact factor: 1.826

3.  Comparison of two contrast materials with different iodine concentrations in enhancing the density of the the aorta, portal vein and liver at multi-detector row CT: a randomized study.

Authors:  Hiromasa Suzuki; Hidekazu Oshima; Norio Shiraki; Chisa Ikeya; Yuta Shibamoto
Journal:  Eur Radiol       Date:  2004-08-12       Impact factor: 5.315

4.  Thoracic spiral CT: delivery of contrast material pushed with injectable saline solution in a power injector.

Authors:  K D Hopper; T J Mosher; C J Kasales; T R TenHave; D A Tully; J S Weaver
Journal:  Radiology       Date:  1997-10       Impact factor: 11.105

Review 5.  Current concepts in contrast media-induced nephropathy.

Authors:  M E Tublin; M E Murphy; F N Tessler
Journal:  AJR Am J Roentgenol       Date:  1998-10       Impact factor: 3.959

6.  Contrast-enhanced CT with saline flush technique using two automated injectors: how much contrast medium does it save?

Authors:  Toshiyuki Irie; Motonao Kajitani; Masayuki Yamaguchi; Yuji Itai
Journal:  J Comput Assist Tomogr       Date:  2002 Mar-Apr       Impact factor: 1.826

7.  Compression of the left brachiocephalic vein: cause of high signal intensity of the left sigmoid sinus and internal jugular vein on MR images.

Authors:  T Tanaka; K Uemura; M Takahashi; S Takehara; T Fukaya; T Tokuyama; A Satoh; H Ryu
Journal:  Radiology       Date:  1993-08       Impact factor: 11.105

8.  Using a saline chaser to decrease contrast media in abdominal CT.

Authors:  Paul J Dorio; Fred T Lee; Kevin P Henseler; Mark Pilot; Myron A Pozniak; Thomas C Winter; Sarah A Shock
Journal:  AJR Am J Roentgenol       Date:  2003-04       Impact factor: 3.959

9.  Abdominal aortic aneurysms at multi-detector row helical CT: optimization with interactive determination of scanning delay and contrast medium dose.

Authors:  Lisa M Ho; Rendon C Nelson; John Thomas; Edgardo I Gimenez; David M DeLong
Journal:  Radiology       Date:  2004-09       Impact factor: 11.105

10.  Single-bolus technique for spiral CT of laryngopharyngeal squamous cell carcinoma: comparison of different contrast material volumes, flow rates, and start delays.

Authors:  Marc Keberle; Alexander Tschammler; Dietbert Hahn
Journal:  Radiology       Date:  2002-07       Impact factor: 11.105

View more
  6 in total

1.  Comparison of different volumes of saline flush in the assessment of perivenous artefacts in the subclavian vein during cervical CT angiography.

Authors:  N Takeyama; Y Ohgiya; T Hayashi; T Takahashi; D Takasu; J Nakashima; K Kato; Y Kinebuchi; T Hashimoto; T Gokan
Journal:  Br J Radiol       Date:  2010-11-02       Impact factor: 3.039

2.  MR angiography at 3 Tesla to assess proximal internal carotid artery stenoses: contrast-enhanced or 3D time-of-flight MR angiography?

Authors:  J Weber; P Veith; B Jung; G Ihorst; O Moske-Eick; S Meckel; H Urbach; C A Taschner
Journal:  Clin Neuroradiol       Date:  2014-01-03       Impact factor: 3.649

3.  Novel connecting tube for saline chaser in contrast-enhanced CT: the effect of spiral flow of saline on contrast enhancement.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Kazuo Awai; Koji Yuba; Takayuki Kobayashi; Young-Kwang Park; Takanobu Yagi; Kazunori Harada; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2013-06-12       Impact factor: 5.315

4.  Comparison of dual-source CT angiography and MR angiography in preoperative evaluation of intra- and extracranial vessels: a pilot study.

Authors:  Georg Mühlenbruch; Marco Das; Gottfried Mommertz; Meike Schaaf; Stefan Langer; Andreas Horst Mahnken; Joachim Ernst Wildberger; A Thron; Rolf W Günther; Timo Krings
Journal:  Eur Radiol       Date:  2009-08-21       Impact factor: 5.315

5.  Spiral flow-generating tube for saline chaser improves aortic enhancement in Gd-EOB-DTPA-enhanced hepatic MRI.

Authors:  Ayumi Iyama; Takeshi Nakaura; Yuji Iyama; Masafumi Kidoh; Yasunori Nagayama; Seitaro Oda; Daisuke Utsunomiya; Tomohiro Namimoto; Kosuke Morita; Koji Yuba; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2018-09-25       Impact factor: 5.315

Review 6.  Multidetector-row CT angiography in the study of atherosclerotic carotid arteries.

Authors:  Luca Saba; Roberto Sanfilippo; Raimondo Pirisi; Luigi Pascalis; Roberto Montisci; Giorgio Mallarini
Journal:  Neuroradiology       Date:  2007-07-03       Impact factor: 2.804

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.