Literature DB >> 27407809

Impact of Multidetector CT on 3D CT Angiography.

I K Indrajit1, J D Souza2, V S Bedi3, R Pant4.   

Abstract

3D Computed Tomographic Angiography (CTA) is a noninvasive volumetric imaging technique increasingly used for evaluation of vascular system. The introduction of Multidetector CT (MDCT) has increased scanning speed, allowing shorter acquisition time, greater volume coverage and decreased contrast requirement while diminishing respiratory motion artifacts. Thin-slice collimation protocols are routinely used which generate isotropic 3D voxels that improve image quality. The ideal CTA study requires scanning at peak vascular enhancement for optimal opacification of arteries with separation of arteries and veins. MDCT has enabled complete lower extremity inflow and runoff studies with a single injection, as well as thin-section CTA covering the entirety of the Carotid arteries and Circle of Willis. Sixteen row MDCT has increased scanning speed further facilitating the development of novel applications such as coronary CTA. CTA when perfomed with MDCT offers a "one scan - many views" option useful in imaging vascular diseases. CTA has important advantages over conventional angiography, such as reduced risk, diminished time and better patient acceptance. With MDCT, 3D CTA is crossing vessel tortuosity and evaluation of vessel fragility.

Entities:  

Keywords:  CT angiography; Multidetector CT; Volume Rendering

Year:  2011        PMID: 27407809      PMCID: PMC4922958          DOI: 10.1016/S0377-1237(05)80068-1

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  20 in total

1.  Multidetector CT angiography in the evaluation of pancreatic carcinoma: preliminary observations.

Authors:  E K Fishman; K M Horton; B A Urban
Journal:  J Comput Assist Tomogr       Date:  2000 Nov-Dec       Impact factor: 1.826

2.  Multi-detector row spiral CT pulmonary angiography: comparison with single-detector row spiral CT.

Authors:  V Raptopoulos; P M Boiselle
Journal:  Radiology       Date:  2001-12       Impact factor: 11.105

3.  Carotid arterial stenosis: evaluation at CT angiography with the volume-rendering technique.

Authors:  C D Marcus; V J Ladam-Marcus; J L Bigot; C Clement; B Baehrel; B P Menanteau
Journal:  Radiology       Date:  1999-06       Impact factor: 11.105

4.  Renal artery stenosis: CT angiography--comparison of real-time volume-rendering and maximum intensity projection algorithms.

Authors:  P T Johnson; E J Halpern; B S Kuszyk; D G Heath; R J Wechsler; L N Nazarian; G A Gardiner; D C Levin; E K Fishman
Journal:  Radiology       Date:  1999-05       Impact factor: 11.105

Review 5.  Technical aspects of CT angiography.

Authors:  B S Kuszyk; E K Fishman
Journal:  Semin Ultrasound CT MR       Date:  1998-10       Impact factor: 1.875

6.  Virtual angioscopy using spiral CT and real-time interactive volume-rendering techniques.

Authors:  P A Smith; D G Heath; E K Fishman
Journal:  J Comput Assist Tomogr       Date:  1998 Mar-Apr       Impact factor: 1.826

7.  CT angiography with volume rendering: imaging findings.

Authors:  B S Kuszyk; D G Heath; D R Ney; D A Bluemke; B A Urban; T P Chambers; E K Fishman
Journal:  AJR Am J Roentgenol       Date:  1995-08       Impact factor: 3.959

8.  Intracranial aneurysms: evaluation in 200 patients with spiral CT angiography.

Authors:  N Young; N W Dorsch; R J Kingston; G Markson; J McMahon
Journal:  Eur Radiol       Date:  2001       Impact factor: 5.315

9.  Aortoiliac and renal arteries: prospective intraindividual comparison of contrast-enhanced three-dimensional MR angiography and multi-detector row CT angiography.

Authors:  Jurgen K Willmann; Simon Wildermuth; Thomas Pfammatter; Justus E Roos; Burkhardt Seifert; Paul R Hilfiker; Borut Marincek; Dominik Weishaupt
Journal:  Radiology       Date:  2003-01-31       Impact factor: 11.105

10.  Using a saline chaser to decrease contrast media in abdominal CT.

Authors:  Paul J Dorio; Fred T Lee; Kevin P Henseler; Mark Pilot; Myron A Pozniak; Thomas C Winter; Sarah A Shock
Journal:  AJR Am J Roentgenol       Date:  2003-04       Impact factor: 3.959

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.