Literature DB >> 11923371

Evaluation of an automated sample preparation protocol for quantitative detection of hepatitis C virus RNA.

Evelyn Stelzl1, Andrea Kormann-Klement, Josef Haas, Elisabeth Daghofer, Brigitte I Santner, Egon Marth, Harald H Kessler.   

Abstract

The COBAS AMPLIPREP instrument for automated sample preparation has recently been introduced. In this study, the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test, which includes this new molecular device, was evaluated and compared to the COBAS AMPLICOR HCV MONITOR test, which includes a manual extraction protocol. Interassay and intra-assay variation, precision, and linearity were determined, and a total of 130 clinical specimens were investigated. For determination of interassay variation, coefficients of variation were found to be between 9 and 59% for the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and between 13 and 69% for the COBAS AMPLICOR HCV MONITOR test. For determination of intra-assay variation, coefficients of variation were found to be between 7 and 13% for the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and between 8 and 16% for the COBAS AMPLICOR HCV MONITOR test. When precision of the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test was tested, all results were found to be within +/-0.5 log of the expected results. Determination of linearity resulted in a quasilinear curve over 3 logs. When clinical samples were tested with the COBAS AMPLIPREP/COBAS AMPLICOR HCV MONITOR test and compared with the COBAS AMPLICOR HCV MONITOR test, all results were found within +/-0.5 log. In conclusion, the assay, which included the new molecular device, proved to be suitable for the routine molecular laboratory. It was found to be laborsaving and easy to handle.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 11923371      PMCID: PMC140388          DOI: 10.1128/JCM.40.4.1447-1450.2002

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  12 in total

1.  Multicenter international work flow study of an automated polymerase chain reaction instrument.

Authors:  P E Klapper; D L Jungkind; T Fenner; R Antinozzi; J Schirm; C Blanckmeister
Journal:  Clin Chem       Date:  1998-08       Impact factor: 8.327

2.  Avoiding false positives with PCR.

Authors:  S Kwok; R Higuchi
Journal:  Nature       Date:  1989-05-18       Impact factor: 49.962

3.  Second generation of the automated Cobas Amplicor HCV assay improves sensitivity of hepatitis C virus RNA detection and yields results that are more clinically relevant.

Authors:  A Doglio; C Laffont; F X Caroli-Bosc; P Rochet; J Lefebvre
Journal:  J Clin Microbiol       Date:  1999-05       Impact factor: 5.948

4.  Comparison of hepatitis B virus DNA extractions from serum by the QIAamp blood kit, GeneReleaser, and the phenol-chloroform method.

Authors:  A Kramvis; S Bukofzer; M C Kew
Journal:  J Clin Microbiol       Date:  1996-11       Impact factor: 5.948

5.  Evaluation of automated COBAS AMPLICOR PCR system for detection of several infectious agents and its impact on laboratory management.

Authors:  D Jungkind; S Direnzo; K G Beavis; N S Silverman
Journal:  J Clin Microbiol       Date:  1996-11       Impact factor: 5.948

Review 6.  The polymerase chain reaction, a review of the practical limitations for human immunodeficiency virus diagnosis.

Authors:  J P Clewley
Journal:  J Virol Methods       Date:  1989-08       Impact factor: 2.014

7.  Multicenter evaluation of the COBAS AMPLICOR HCV assay, an integrated PCR system for rapid detection of hepatitis C virus RNA in the diagnostic laboratory.

Authors:  J Albadalejo; R Alonso; R Antinozzi; M Bogard; A M Bourgault; G Colucci; T Fenner; H Petersen; E Sala; J Vincelette; C Young
Journal:  J Clin Microbiol       Date:  1998-04       Impact factor: 5.948

8.  Evaluation of the automated COBAS AMPLICOR hepatitis C virus PCR system.

Authors:  M Poljak; K Seme; S Koren
Journal:  J Clin Microbiol       Date:  1997-11       Impact factor: 5.948

9.  Performance of the automated COBAS AMPLICOR system for the detection of hepatitis C virus RNA.

Authors:  H H Kessler; E A Dragon; K Pierer; B I Santner; Y Liao; D Stünzner; E Stelzl; E Marth
Journal:  Clin Diagn Virol       Date:  1997-02

Review 10.  Automation of laboratory testing for infectious diseases using the polymerase chain reaction-- our past, our present, our future.

Authors:  D Jungkind
Journal:  J Clin Virol       Date:  2001-01       Impact factor: 3.168

View more
  12 in total

1.  Evaluation of a new automated, standardized generic nucleic acid extraction method (total nucleic acid isolation kit) used in combination with cytomegalovirus DNA quantification by COBAS AMPLICOR CMV MONITOR.

Authors:  Barbara Christine Gärtner; Johannes Michael Fischinger; Anke Litwicki; Klaus Roemer; Nikolaus Mueller-Lantzsch
Journal:  J Clin Microbiol       Date:  2004-08       Impact factor: 5.948

2.  Impact of the COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, Version 1.5, on clinical laboratory operations.

Authors:  Jeffrey J Germer; Jordan L Bendel; Craig A Dolenc; Sarah R Nelson; Amanda L Masters; Tara M Gerads; Jayawant N Mandrekar; P Shawn Mitchell; Joseph D C Yao
Journal:  J Clin Microbiol       Date:  2007-07-18       Impact factor: 5.948

3.  Genotype 3 diversity and quantification of hepatitis E virus RNA.

Authors:  Florence Abravanel; Karine Sandres-Saune; Sebastien Lhomme; Martine Dubois; Jean-Michel Mansuy; Jacques Izopet
Journal:  J Clin Microbiol       Date:  2012-01-11       Impact factor: 5.948

4.  Comparison of qualitative (COBAS AMPLICOR HCV 2.0 versus VERSANT HCV RNA) and quantitative (COBAS AMPLICOR HCV monitor 2.0 versus VERSANT HCV RNA 3.0) assays for hepatitis C virus (HCV) RNA detection and quantification: impact on diagnosis and treatment of HCV infections.

Authors:  Isabelle Desombere; Hans Van Vlierberghe; Sibyl Couvent; Filip Clinckspoor; Geert Leroux-Roels
Journal:  J Clin Microbiol       Date:  2005-06       Impact factor: 5.948

5.  Development and verification of an automated sample processing protocol for quantitation of human immunodeficiency virus type 1 RNA in plasma.

Authors:  Brenda G Lee; Kristin R Fiebelkorn; Angela M Caliendo; Frederick S Nolte
Journal:  J Clin Microbiol       Date:  2003-05       Impact factor: 5.948

6.  Evaluation of automated sample preparation and quantitative PCR LCx assay for determination of human immunodeficiency virus type 1 RNA.

Authors:  Zsofia Muller; Evelyn Stelzl; Michael Bozic; Josef Haas; Egon Marth; Harald H Kessler
Journal:  J Clin Microbiol       Date:  2004-04       Impact factor: 5.948

7.  Performance characteristics of a quantitative hepatitis C virus RNA assay using COBAS AmpliPrep total nucleic acid isolation and COBAS taqman hepatitis C virus analyte-specific reagent.

Authors:  Michael S Forman; Alexandra Valsamakis
Journal:  J Mol Diagn       Date:  2008-02-14       Impact factor: 5.568

8.  Quantification of parvovirus B19 DNA using COBAS AmpliPrep automated sample preparation and LightCycler real-time PCR.

Authors:  Stefan Schorling; Gunnar Schalasta; Gisela Enders; Michael Zauke
Journal:  J Mol Diagn       Date:  2004-02       Impact factor: 5.568

9.  Improved COBAS TaqMan hepatitis C virus test (Version 2.0) for use with the High Pure system: enhanced genotype inclusivity and performance characteristics in a multisite study.

Authors:  G Colucci; J Ferguson; C Harkleroad; S Lee; D Romo; S Soviero; J Thompson; M Velez; A Wang; Y Miyahara; S Young; C Sarrazin
Journal:  J Clin Microbiol       Date:  2007-09-26       Impact factor: 5.948

10.  Rapid quantification of hepatitis B virus DNA by automated sample preparation and real-time PCR.

Authors:  Evelyn Stelzl; Zsofia Muller; Egon Marth; Harald H Kessler
Journal:  J Clin Microbiol       Date:  2004-06       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.