Literature DB >> 12734249

Development and verification of an automated sample processing protocol for quantitation of human immunodeficiency virus type 1 RNA in plasma.

Brenda G Lee1, Kristin R Fiebelkorn, Angela M Caliendo, Frederick S Nolte.   

Abstract

We developed and verified an automated sample processing protocol for use with the AMPLICOR HIV-1 MONITOR test, version 1.5 (Roche Diagnostics, Indianapolis, Ind.). The automated method uses the MagNA Pure LC instrument and total nucleic acid reagents (Roche Applied Science, Indianapolis, Ind.) to extract human immunodeficiency virus type 1 (HIV-1) RNA from plasma specimens. We compared the HIV-1 load results for a dilution series (1 to 5 nominal log(10) copies/ml) and 175 clinical specimens processed by the automated method to those for the same samples processed by the manual methods specified by the manufacturer. The sensitivity, dynamic range, and precision of the viral load assay obtained by automated processing of specimens were similar to those obtained by an ultrasensitive manual processing method. The results were highly correlated (R(2), 0.95), and were in close agreement, with a mean difference of 0.09 log(10) (standard deviation, 0.292). The limits of agreement were +/-0.58 log(10) for results for samples processed by both the manual and the automated methods. These performance characteristics were achieved with a smaller sample volume (200 versus 500 microl) and without a high-speed centrifugation step and required only 15 min of labor for a batch of 32 samples. In conclusion, the automated sample preparation protocol can replace both the standard and the ultrasensitive manual methods used with the AMPLICOR HIV-1 MONITOR test and can substantially reduce the labor associated with this test.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12734249      PMCID: PMC154724          DOI: 10.1128/JCM.41.5.2062-2067.2003

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  7 in total

1.  Fully automated nucleic acid extraction: MagNA Pure LC.

Authors:  H H Kessler; G Mühlbauer; E Stelzl; E Daghofer; B I Santner; E Marth
Journal:  Clin Chem       Date:  2001-06       Impact factor: 8.327

2.  Detection of herpes simplex virus DNA in genital and dermal specimens by LightCycler PCR after extraction using the IsoQuick, MagNA Pure, and BioRobot 9604 methods.

Authors:  M J Espy; P N Rys; A D Wold; J R Uhl; L M Sloan; G D Jenkins; D M Ilstrup; F R Cockerill; R Patel; J E Rosenblatt; T F Smith
Journal:  J Clin Microbiol       Date:  2001-06       Impact factor: 5.948

3.  Clinical evaluation of an automated nucleic acid isolation system.

Authors:  Kristin R Fiebelkorn; Brenda G Lee; Charles E Hill; Angela M Caliendo; Frederick S Nolte
Journal:  Clin Chem       Date:  2002-09       Impact factor: 8.327

Review 4.  HIV viral load markers in clinical practice.

Authors:  M S Saag; M Holodniy; D R Kuritzkes; W A O'Brien; R Coombs; M E Poscher; D M Jacobsen; G M Shaw; D D Richman; P A Volberding
Journal:  Nat Med       Date:  1996-06       Impact factor: 53.440

5.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

6.  Automated extraction of genomic DNA from medically important yeast species and filamentous fungi by using the MagNA Pure LC system.

Authors:  Juergen Loeffler; Kathrin Schmidt; Holger Hebart; Ulrike Schumacher; Hermann Einsele
Journal:  J Clin Microbiol       Date:  2002-06       Impact factor: 5.948

7.  Evaluation of an automated sample preparation protocol for quantitative detection of hepatitis C virus RNA.

Authors:  Evelyn Stelzl; Andrea Kormann-Klement; Josef Haas; Elisabeth Daghofer; Brigitte I Santner; Egon Marth; Harald H Kessler
Journal:  J Clin Microbiol       Date:  2002-04       Impact factor: 5.948

  7 in total
  4 in total

1.  Comparison of five methods for extraction of Legionella pneumophila from respiratory specimens.

Authors:  Deborah Wilson; Belinda Yen-Lieberman; Udo Reischl; Ilka Warshawsky; Gary W Procop
Journal:  J Clin Microbiol       Date:  2004-12       Impact factor: 5.948

2.  Reduced PCR sensitivity due to impaired DNA recovery with the MagNA Pure LC total nucleic acid isolation kit.

Authors:  Tim Schuurman; Alex van Breda; Richard de Boer; Mirjam Kooistra-Smid; Marcel Beld; Paul Savelkoul; René Boom
Journal:  J Clin Microbiol       Date:  2005-09       Impact factor: 5.948

3.  Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens.

Authors:  K Loens; K Bergs; D Ursi; H Goossens; M Ieven
Journal:  J Clin Microbiol       Date:  2006-12-13       Impact factor: 5.948

4.  Plasma load discrepancies between the Roche Cobas Amplicor human immunodeficiency virus type 1 (HIV-1) Monitor version 1.5 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 assays.

Authors:  Joseph D C Yao; Jeffrey J Germer; F Damond; B Roquebert; D Descamps
Journal:  J Clin Microbiol       Date:  2008-02       Impact factor: 5.948

  4 in total