Literature DB >> 11673304

A comparison of stereoscopic and monoscopic evaluation of optic disc topography using a digital optic disc stereo camera.

B Parkin1, G Shuttleworth, M Costen, C Davison.   

Abstract

AIMS: To compare stereophotographic and monophotographic optic disc assessments made using a digital optic disc stereo camera.
METHODS: Stereo digital optic disc photographs of 150 selected patients who had presented to a glaucoma clinic were assessed by two masked observers on separate occasions using (1) the stereophotographs and a stereoviewer, (2) a single image from the same stereopair. Results were analysed for both right and left eyes separately. 95% tolerance limits for change (TC) and intraclass correlation coefficients (ICC) were calculated and a multivariate analysis using a general linear model for repeated measures was performed.
RESULTS: A total of 201 optic disc images of 150 patients (84 females, 108 left eyes) were analysed. Mean age of patients was 64 years. The results for right eyes are as follows (similar results were obtained for left eyes). Intraobserver (stereoscopic compared to monoscopic) measurements of: horizontal cup:disc ratios (CDR), ICC = 0.5995 and 0.7269, TC = 34% and 27%; vertical CDR, ICC = 0.8298 and 0.817, TC = 25% and 27%; area CDR, ICC = 0.7757 and 0.8259, TC = 28% and 25%; circumference CDR, ICC = 0.7618 and 0.8103, TC = 28% and 25%. Interobserver measurements of: horizontal CDR, ICC stereoscopic (SS) = 0.7287; monoscopic (MS) = 0.5030; TC SS = 30%; MS = 32%; vertical CDR, ICC SS = 0.8439; MS = 0.7106; TC SS = 25%; MS = 31%; area CDR, ICC SS = 0.8392; MS = 0.6276; TC SS = 26%; MS = 32%; circumference CDR, ICC SS = 0.8433; MS = 0.6438, TC SS = 26%; MS = 31%. Systematic bias between observers and between methods was within acceptable limits.
CONCLUSIONS: This study using a digital stereo camera indicates that there may be little benefit of stereoscopic imaging over monoscopic imaging despite demonstrating small but inconsistent differences between both observers and methods.

Entities:  

Mesh:

Year:  2001        PMID: 11673304      PMCID: PMC1723792          DOI: 10.1136/bjo.85.11.1347

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  12 in total

1.  A new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurements.

Authors:  G N Shuttleworth; C H Khong; J P Diamond
Journal:  Br J Ophthalmol       Date:  2000-04       Impact factor: 4.638

2.  Randomized controlled clinical trial. National Eye Institute workshop for ophthalmologists. Standardizing diagnostic procedures.

Authors:  H A Kahn; H Leibowitz; J P Ganley; M Kini; T Colton; R Nickerson; T R Dawber
Journal:  Am J Ophthalmol       Date:  1975-05       Impact factor: 5.258

3.  Expert agreement in evaluating the optic disc for glaucoma.

Authors:  R Varma; W C Steinmann; I U Scott
Journal:  Ophthalmology       Date:  1992-02       Impact factor: 12.079

4.  Relative optic cup depth assessments using three stereo photograph viewing methods.

Authors:  D A Boes; G L Spaeth; R P Mills; M Smith; J E Nicholl; B C Clifton
Journal:  J Glaucoma       Date:  1996-02       Impact factor: 2.503

5.  Methodologic differences and measurement of cup-disc ratio: an epidemiologic assessment.

Authors:  J T Schwartz
Journal:  Arch Ophthalmol       Date:  1976-07

6.  Optic disc cupping as clinically estimated from photographs.

Authors:  B E Klein; S E Moss; Y L Magli; R Klein; J C Johnson; H Roth
Journal:  Ophthalmology       Date:  1987-11       Impact factor: 12.079

7.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

8.  Comparative reproducibility of the digital photogrammetric procedure utilizing three methods of stereophotography.

Authors:  A R Rosenthal; M S Kottler; D D Donaldson; D G Falconer
Journal:  Invest Ophthalmol Vis Sci       Date:  1977-01       Impact factor: 4.799

9.  Comparison of photographic techniques and films used in stereophotogrammetry of the optic disk.

Authors:  M A Krohn; J L Keltner; C A Johnson
Journal:  Am J Ophthalmol       Date:  1979-11       Impact factor: 5.258

10.  The Bristol Shared Care Glaucoma Study: reliability of community optometric and hospital eye service test measures.

Authors:  P G Spry; I C Spencer; J M Sparrow; T J Peters; S T Brookes; S Gray; I Baker; J E Furber; D L Easty
Journal:  Br J Ophthalmol       Date:  1999-06       Impact factor: 4.638

View more
  13 in total

1.  Utility of digital stereo images for optic disc evaluation.

Authors:  Richard A Stone; Gui-Shuang Ying; Denise J Pearson; Mayank Bansal; Manika Puri; Eydie Miller; Judith Alexander; Jody Piltz-Seymour; William Nyberg; Maureen G Maguire; Jayan Eledath; Harpreet Sawhney
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-05-26       Impact factor: 4.799

2.  Digital imaging of the optic nerve head: monoscopic and stereoscopic analysis.

Authors:  J E Morgan; N J L Sheen; R V North; Y Choong; E Ansari
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

3.  A comparison of cup-to-disc ratio estimates by fundus biomicroscopy and stereoscopic optic disc photography in the Tema Eye Survey.

Authors:  J C Mwanza; D S Grover; D L Budenz; L W Herndon; W Nolan; J Whiteside-de Vos; G Hay-Smith; J R Bandi; K A Bhansali; L A Forbes; W J Feuer; K Barton
Journal:  Eye (Lond)       Date:  2017-04-07       Impact factor: 3.775

4.  Agreement among ophthalmologists in marking the optic disc and optic cup in fundus images.

Authors:  Ahmed Almazroa; Sami Alodhayb; Essameldin Osman; Eslam Ramadan; Mohammed Hummadi; Mohammed Dlaim; Muhannad Alkatee; Kaamran Raahemifar; Vasudevan Lakshminarayanan
Journal:  Int Ophthalmol       Date:  2016-08-30       Impact factor: 2.031

5.  Automated segmentation of the optic disc from stereo color photographs using physiologically plausible features.

Authors:  Michael D Abràmoff; Wallace L M Alward; Emily C Greenlee; Lesya Shuba; Chan Y Kim; John H Fingert; Young H Kwon
Journal:  Invest Ophthalmol Vis Sci       Date:  2007-04       Impact factor: 4.799

6.  Glaucoma and mortality risk: findings from a prospective population-based study.

Authors:  Tilman Kühn; Sabine Rohrmann; Nena Karavasiloglou; David S Friedman; Aedin Cassidy; Till Bärnighausen; Alexander K Schuster; Stefan Nickels
Journal:  Sci Rep       Date:  2021-06-03       Impact factor: 4.379

7.  Stereoscopic analysis of optic nerve head parameters in primary open angle glaucoma: the glaucoma stereo analysis study.

Authors:  Yu Yokoyama; Masaki Tanito; Koji Nitta; Maki Katai; Yasushi Kitaoka; Kazuko Omodaka; Satoru Tsuda; Toshiaki Nakagawa; Toru Nakazawa
Journal:  PLoS One       Date:  2014-06-12       Impact factor: 3.240

8.  Assessment of stereoscopic optic disc images using an autostereoscopic screen - experimental study.

Authors:  Maged S Habib; James A Lowell; Nick S Holliman; Andrew Hunter; Daniella Vaideanu; Anthony Hildreth; David Hw Steel
Journal:  BMC Ophthalmol       Date:  2008-07-23       Impact factor: 2.209

9.  Scanning the macula for detecting glaucoma.

Authors:  Viquar U Begum; Ganesh B Jonnadula; Ravi K Yadav; Uday K Addepalli; Sirisha Senthil; Nikhil S Choudhari; Chandra S Garudadri; Harsha L Rao
Journal:  Indian J Ophthalmol       Date:  2014-01       Impact factor: 1.848

10.  Software-Assisted Depth Analysis of Optic Nerve Stereoscopic Images in Telemedicine.

Authors:  Tian Xia; Shriji N Patel; Ben C Szirth; Anton M Kolomeyer; Albert S Khouri
Journal:  Int J Telemed Appl       Date:  2016-04-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.