Literature DB >> 8795728

Relative optic cup depth assessments using three stereo photograph viewing methods.

D A Boes1, G L Spaeth, R P Mills, M Smith, J E Nicholl, B C Clifton.   

Abstract

PURPOSE: A consistent stereoscopic (stereo) effect in disc photographs is important to be certain that apparent depth changes are real and are not the result of artifact caused by a variable stereo angle. The purpose of this study is to compare the accuracy of relative depth assessments using three different stereo photo viewing methods.
METHODS: We evaluated the ability of 12 observers to arrange sets of simultaneous stereo photographs (Nidek 3-Dx split-frame slides, Lentec transparencies) and sequential stereo photographs (Zeiss full-frame slides) according to apparent cup depth. Observer arrangements of each set of 10 photographs were compared to a "reference standard" sequence determined from cup depth measurements made by the Imagenet optic nerve analyzer.
RESULTS: The median number of sequence errors (n = 6) made by all examiners in arranging the Nidek 3-Dx simultaneous stereo slides was significantly lower than the median number of errors (n = 12) with the Zeiss sequential stereo slides.
CONCLUSIONS: Simultaneous stereo slides provide significantly more interobserver consistency for judgements of cup depth than sequential stereo slides.

Entities:  

Mesh:

Year:  1996        PMID: 8795728

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  5 in total

1.  A new digital optic disc stereo camera: intraobserver and interobserver repeatability of optic disc measurements.

Authors:  G N Shuttleworth; C H Khong; J P Diamond
Journal:  Br J Ophthalmol       Date:  2000-04       Impact factor: 4.638

2.  A comparison of stereoscopic and monoscopic evaluation of optic disc topography using a digital optic disc stereo camera.

Authors:  B Parkin; G Shuttleworth; M Costen; C Davison
Journal:  Br J Ophthalmol       Date:  2001-11       Impact factor: 4.638

3.  Digital imaging of the optic nerve head: monoscopic and stereoscopic analysis.

Authors:  J E Morgan; N J L Sheen; R V North; Y Choong; E Ansari
Journal:  Br J Ophthalmol       Date:  2005-07       Impact factor: 4.638

Review 4.  [Optic disc photography and retinal nerve fiber layer photography].

Authors:  E M Hoffmann
Journal:  Ophthalmologe       Date:  2009-08       Impact factor: 1.059

5.  Morphometric analysis and classification of glaucomatous optic neuropathy using radial polynomials.

Authors:  Michael D Twa; Srinivasan Parthasarathy; Chris A Johnson; Mark A Bullimore
Journal:  J Glaucoma       Date:  2012 Jun-Jul       Impact factor: 2.503

  5 in total