Literature DB >> 8978639

Intravascular magnetic resonance imaging using a loopless catheter antenna.

O Ocali1, E Atalar.   

Abstract

Recently, intravascular catheter probes have been developed to increase signal-to-noise ratio (SNR) for MR imaging of blood vessels. Miniaturization of these catheter probes without degrading their performances is very critical in imaging small vessels such as coronary arteries. Catheter coils have a loop incorporated in their structure and have limitations in physical dimensions and electromagnetic properties. The use of a loopless intravascular catheter antenna is proposed to overcome these problems. The catheter antenna is essentially a dipole, which makes a very thin diameter possible, and its electronic circuitry can be placed outside the blood vessels without performance degradation. The theoretical foundation for the design and operation of the catheter antenna is presented. Several catheter antennae, as small as 1.5 French, were constructed and tested on phantoms and rabbits with great success. The catheter antenna has a simple structure and is easy to design, implement, and operate.

Entities:  

Mesh:

Year:  1997        PMID: 8978639     DOI: 10.1002/mrm.1910370116

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  54 in total

1.  Planar strip array (PSA) for MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; D C Newman; P A Bottomley
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Microimaging of atherosclerotic plaque in animal models.

Authors:  L Chaabane; E Canet; J M Serfaty; F Contard; D Guerrier; P Douek; A Briguet
Journal:  MAGMA       Date:  2000-11       Impact factor: 2.310

3.  Cardiovascular MRI probes for the outside in and for the inside out.

Authors:  P A Bottomley; E Atalar; R F Lee; K A Shunk; A Lardo
Journal:  MAGMA       Date:  2000-11       Impact factor: 2.310

4.  A brief review of hardware for catheter tracking in magnetic resonance imaging.

Authors:  Jeffrey L Duerk; Eddy Y Wong; Jonathan S Lewin
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

5.  Interventional loopless antenna at 7 T.

Authors:  Mehmet Arcan Ertürk; Abdel-Monem M El-Sharkawy; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

Review 6.  Magnetic resonance imaging of coronary atherosclerosis.

Authors:  Zahi A Fayad; Robin P Choudhury; Valentin Fuster
Journal:  Curr Atheroscler Rep       Date:  2003-09       Impact factor: 5.113

7.  Interventional MR imaging with an endospinal imaging coil: preliminary results with anatomic imaging of the canine and cadaver spinal cord.

Authors:  George Rappard; Gregory J Metzger; Paul T Weatherall; Phillip D Purdy
Journal:  AJNR Am J Neuroradiol       Date:  2004-05       Impact factor: 3.825

Review 8.  Cardiovascular interventional magnetic resonance imaging.

Authors:  Robert J Lederman
Journal:  Circulation       Date:  2005-11-08       Impact factor: 29.690

9.  A combined interventional high-resolution targeted ablation, thermometry and imaging probe.

Authors:  M Arcan Erturk; Shashank Sathyanarayana Hegde; Paul A Bottomley
Journal:  Proc Int Soc Magn Reson Med Sci Meet Exhib Int Soc Magn Reson Med Sci Meet Exhib       Date:  2015 May-Jun

Review 10.  Interventional cardiovascular magnetic resonance imaging: a new opportunity for image-guided interventions.

Authors:  Christina E Saikus; Robert J Lederman
Journal:  JACC Cardiovasc Imaging       Date:  2009-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.