Literature DB >> 10800037

An analytical SMASH procedure (ASP) for sensitivity-encoded MRI.

R F Lee1, C R Westgate, R G Weiss, P A Bottomley.   

Abstract

The simultaneous acquisition of spatial harmonics (SMASH) method of imaging with detector arrays can reduce the number of phase-encoding steps, and MRI scan time several-fold. The original approach utilized numerical gradient-descent fitting with the coil sensitivity profiles to create a set of composite spatial harmonics to replace the phase-encoding steps. Here, an analytical approach for generating the harmonics is presented. A transform is derived to project the harmonics onto a set of sensitivity profiles. A sequence of Fourier, Hilbert, and inverse Fourier transform is then applied to analytically eliminate spatially dependent phase errors from the different coils while fully preserving the spatial-encoding. By combining the transform and phase correction, the original numerical image reconstruction method can be replaced by an analytical SMASH procedure (ASP). The approach also allows simulation of SMASH imaging, revealing a criterion for the ratio of the detector sensitivity profile width to the detector spacing that produces optimal harmonic generation. When detector geometry is suboptimal, a group of quasi-harmonics arises, which can be corrected and restored to pure harmonics. The simulation also reveals high-order harmonic modulation effects, and a demodulation procedure is presented that enables application of ASP to a large numbers of detectors. The method is demonstrated on a phantom and humans using a standard 4-channel phased-array MRI system. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2000        PMID: 10800037      PMCID: PMC1941706          DOI: 10.1002/(sici)1522-2594(200005)43:5<716::aid-mrm14>3.0.co;2-k

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

3.  A decoupled coil detector array for fast image acquisition in magnetic resonance imaging.

Authors:  D Kwiat; S Einav; G Navon
Journal:  Med Phys       Date:  1991 Mar-Apr       Impact factor: 4.071

4.  Arrays of mutually coupled receiver coils: theory and application.

Authors:  S M Wright; R L Magin; J R Kelton
Journal:  Magn Reson Med       Date:  1991-01       Impact factor: 4.668

5.  AUTO-SMASH: a self-calibrating technique for SMASH imaging. SiMultaneous Acquisition of Spatial Harmonics.

Authors:  P M Jakob; M A Griswold; R R Edelman; D K Sodickson
Journal:  MAGMA       Date:  1998-11       Impact factor: 2.310

6.  What is the optimum phased array coil design for cardiac and torso magnetic resonance?

Authors:  P A Bottomley; C H Lugo Olivieri; R Giaquinto
Journal:  Magn Reson Med       Date:  1997-04       Impact factor: 4.668

7.  Fast MRI data acquisition using multiple detectors.

Authors:  M Hutchinson; U Raff
Journal:  Magn Reson Med       Date:  1988-01       Impact factor: 4.668

8.  Calculation of the signal-to-noise ratio for simple surface coils and arrays of coils.

Authors:  J Wang; A Reykowski; J Dickas
Journal:  IEEE Trans Biomed Eng       Date:  1995-09       Impact factor: 4.538

9.  Fast imaging using subencoding data sets from multiple detectors.

Authors:  J B Ra; C Y Rim
Journal:  Magn Reson Med       Date:  1993-07       Impact factor: 4.668

10.  An NMR phased array for human cardiac 31P spectroscopy.

Authors:  C J Hardy; P A Bottomley; K W Rohling; P B Roemer
Journal:  Magn Reson Med       Date:  1992-11       Impact factor: 4.668

View more
  3 in total

1.  Planar strip array (PSA) for MRI.

Authors:  R F Lee; C R Westgate; R G Weiss; D C Newman; P A Bottomley
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Cardiovascular MRI probes for the outside in and for the inside out.

Authors:  P A Bottomley; E Atalar; R F Lee; K A Shunk; A Lardo
Journal:  MAGMA       Date:  2000-11       Impact factor: 2.310

3.  Recent advances in image reconstruction, coil sensitivity calibration, and coil array design for SMASH and generalized parallel MRI.

Authors:  Daniel K Sodickson; Charles A McKenzie; Michael A Ohliger; Ernest N Yeh; Mark D Price
Journal:  MAGMA       Date:  2002-01       Impact factor: 2.310

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.