Referenceless interleaved echo-planar imaging.

S B Reeder1, E Atalar, A Z Faranesh, E R McVeigh.   

Abstract

Interleaved echo-planar imaging (EPI) is an ultrafast imaging technique important for applications that require high time resolution or short total acquisition times. Unfortunately, EPI is prone to significant ghosting artifacts, resulting primarily from system time delays that cause data matrix misregistration. In this work, it is shown mathematically and experimentally that system time delays are orientation dependent, resulting from anisotropic physical gradient delays. This analysis characterizes the behavior of time delays in oblique coordinates, and a new ghosting artifact caused by anisotropic delays is described. "Compensation blips" are proposed for time delay correction. These blips are shown to remove the effects of anisotropic gradient delays, eliminating the need for repeated reference scans and postprocessing corrections. Examples of phantom and in vivo images are shown.

Entities:  

Mesh:

Year:  1999        PMID: 10025615      PMCID: PMC2396321          DOI: 10.1002/(sici)1522-2594(199901)41:1<87::aid-mrm13>3.0.co;2-x

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Multi-echo segmented k-space imaging: an optimized hybrid sequence for ultrafast cardiac imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-02       Impact factor: 4.668

2.  Analysis of eddy currents in nuclear magnetic resonance imaging.

Authors:  C B Ahn; Z H Cho
Journal:  Magn Reson Med       Date:  1991-01       Impact factor: 4.668

Review 3.  Echo-planar imaging: magnetic resonance imaging in a fraction of a second.

Authors:  M K Stehling; R Turner; P Mansfield
Journal:  Science       Date:  1991-10-04       Impact factor: 47.728

4.  In vivo measurement of T*2 and field inhomogeneity maps in the human heart at 1.5 T.

Authors:  S B Reeder; A Z Faranesh; J L Boxerman; E R McVeigh
Journal:  Magn Reson Med       Date:  1998-06       Impact factor: 4.668

5.  Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging.

Authors:  S B Reeder; E Atalar; B D Bolster; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

Review 6.  Functional magnetic resonance imaging with echo planar imaging.

Authors:  K K Kwong
Journal:  Magn Reson Q       Date:  1995-03

7.  Ultrafast interleaved gradient-echo-planar imaging on a standard scanner.

Authors:  G C McKinnon
Journal:  Magn Reson Med       Date:  1993-11       Impact factor: 4.668

8.  Echo-planar imaging of the liver with a standard MR imaging system.

Authors:  K Butts; S J Riederer; R L Ehman; J P Felmlee; R C Grimm
Journal:  Radiology       Date:  1993-10       Impact factor: 11.105

9.  Minimization of dead-periods in MRI pulse sequences for imaging oblique planes.

Authors:  E Atalar; E R McVeigh
Journal:  Magn Reson Med       Date:  1994-12       Impact factor: 4.668

10.  Ultrafast magnetic resonance imaging: diffusion and perfusion.

Authors:  M E Moseley; R Sevick; M F Wendland; D L White; J Mintorovitch; H S Asgari; J Kucharczyk
Journal:  Can Assoc Radiol J       Date:  1991-02       Impact factor: 2.248

View more
  22 in total

1.  A novel object-independent "balanced" reference scan for echo-planar imaging.

Authors:  S B Reeder; A Z Faranesh; E Atalar; E R McVeigh
Journal:  J Magn Reson Imaging       Date:  1999-06       Impact factor: 4.813

2.  Centering the projection reconstruction trajectory: reducing gradient delay errors.

Authors:  Dana C Peters; J Andrew Derbyshire; Elliot R McVeigh
Journal:  Magn Reson Med       Date:  2003-07       Impact factor: 4.668

3.  Robust EPI Nyquist ghost elimination via spatial and temporal encoding.

Authors:  W Scott Hoge; Huan Tan; Robert A Kraft
Journal:  Magn Reson Med       Date:  2010-07-27       Impact factor: 4.668

4.  A Wireless Radio Frequency Triggered Acquisition Device (WRAD) for Self-Synchronised Measurements of the Rate of Change of the MRI Gradient Vector Field for Motion Tracking.

Authors:  Adam van Niekerk; Ernesta Meintjes; Andre van der Kouwe
Journal:  IEEE Trans Med Imaging       Date:  2019-01-10       Impact factor: 10.048

5.  Characterizing and correcting gradient errors in non-cartesian imaging: Are gradient errors linear time-invariant (LTI)?

Authors:  Ethan K Brodsky; Alexey A Samsonov; Walter F Block
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

6.  Two-dimensional phase cycled reconstruction for inherent correction of echo-planar imaging Nyquist artifacts.

Authors:  Nan-Kuei Chen; Alexandru V Avram; Allen W Song
Journal:  Magn Reson Med       Date:  2011-03-28       Impact factor: 4.668

7.  Navigator-Free EPI Ghost Correction With Structured Low-Rank Matrix Models: New Theory and Methods.

Authors:  Rodrigo A Lobos; Tae Hyung Kim; W Scott Hoge; Justin P Haldar
Journal:  IEEE Trans Med Imaging       Date:  2018-04-02       Impact factor: 10.048

8.  Phase and amplitude correction for multi-echo water-fat separation with bipolar acquisitions.

Authors:  Huanzhou Yu; Ann Shimakawa; Charles A McKenzie; Wenmiao Lu; Scott B Reeder; R Scott Hinks; Jean H Brittain
Journal:  J Magn Reson Imaging       Date:  2010-05       Impact factor: 4.813

9.  Acquiring and processing ultrafast biomolecular 2D NMR experiments using a referenced-based correction.

Authors:  Amir Seginer; Gregory L Olsen; Lucio Frydman
Journal:  J Biomol NMR       Date:  2016-09-28       Impact factor: 2.835

10.  Real-Time Filtering with Sparse Variations for Head Motion in Magnetic Resonance Imaging.

Authors:  Daniel S Weller; Douglas C Noll; Jeffrey A Fessler
Journal:  Signal Processing       Date:  2018-12-03       Impact factor: 4.662

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.