Literature DB >> 2067391

Analysis of eddy currents in nuclear magnetic resonance imaging.

C B Ahn1, Z H Cho.   

Abstract

The eddy currents in nuclear magnetic resonance (NMR) imaging are analyzed from the solutions of Maxwell's equations and their effects are examined over various experimental conditions from whole-body diagnostic imaging to recently developed NMR microscopy. The analysis is focused mainly on the frequency characteristics and intensity variations of the eddy-current-induced field which depends on the overall system size, ratio of the gradient coil size to the magnet bore diameter, and the pulse-sequence-dependent parameters such as input current waveform and repetition time. From the analysis, the frequency response of the eddy-current-induced field is that of a high-pass filter whose cutoff frequency is inversely proportional to the square of the overall system size. The intensity ratio of the generated field to the induced field is not affected by the overall system size, but is sensitively related to the ratio of the gradient coil size to the magnet bore diameter.

Mesh:

Year:  1991        PMID: 2067391     DOI: 10.1002/mrm.1910170119

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  A novel object-independent "balanced" reference scan for echo-planar imaging.

Authors:  S B Reeder; A Z Faranesh; E Atalar; E R McVeigh
Journal:  J Magn Reson Imaging       Date:  1999-06       Impact factor: 4.813

2.  Referenceless interleaved echo-planar imaging.

Authors:  S B Reeder; E Atalar; A Z Faranesh; E R McVeigh
Journal:  Magn Reson Med       Date:  1999-01       Impact factor: 4.668

3.  Quantification and reduction of ghosting artifacts in interleaved echo-planar imaging.

Authors:  S B Reeder; E Atalar; B D Bolster; E R McVeigh
Journal:  Magn Reson Med       Date:  1997-09       Impact factor: 4.668

4.  Low eddy current RF shielding enclosure designs for 3T MR applications.

Authors:  Brian J Lee; Ronald D Watkins; Chen-Ming Chang; Craig S Levin
Journal:  Magn Reson Med       Date:  2017-06-06       Impact factor: 4.668

5.  Technical Note: Effect of transducer position and ground plane configuration on image quality in MR-guided focused ultrasound therapies.

Authors:  Allison Payne; Emilee Minalga; Robb Merrill; Dennis L Parker; J Rock Hadley
Journal:  Med Phys       Date:  2020-04-06       Impact factor: 4.071

6.  Reduction of flow- and eddy-currents-induced image artifacts in coronary magnetic resonance angiography using a linear centric-encoding SSFP sequence.

Authors:  Xiaoming Bi; Jaeseok Park; Vibhas Deshpande; Orlando Simonetti; Gerhard Laub; Debiao Li
Journal:  Magn Reson Imaging       Date:  2007-02-20       Impact factor: 2.546

7.  Sequence optimization to reduce velocity offsets in cardiovascular magnetic resonance volume flow quantification--a multi-vendor study.

Authors:  Marijn P Rolf; Mark B M Hofman; Peter D Gatehouse; Karin Markenroth-Bloch; Martijn W Heymans; Tino Ebbers; Martin J Graves; John J Totman; Beat Werner; Albert C van Rossum; Philip J Kilner; Rob M Heethaar
Journal:  J Cardiovasc Magn Reson       Date:  2011-03-09       Impact factor: 5.364

8.  Evaluating diffusion dispersion across an extended range of b-values and frequencies: Exploiting gap-filled OGSE shapes, strong gradients, and spiral readouts.

Authors:  Eric Seth Michael; Franciszek Hennel; Klaas Paul Pruessmann
Journal:  Magn Reson Med       Date:  2022-01-20       Impact factor: 3.737