Literature DB >> 9619923

The value of preoperative planning for total hip arthroplasty.

S Eggli1, M Pisan, M E Müller.   

Abstract

To analyse the value and accuracy of preoperative planning for total hip replacement (THR) we digitised electronically and compared the hand-sketched preoperative plans with the pre- and postoperative radiographs of 100 consecutive primary THRs. The correct type of prosthesis was planned in 98%; the agreement between planned and actually used components was 92% on the femoral side and 90% on the acetabular side. The mean (+/- SD) absolute difference between the planned and actual position of the centre of rotation of the hip was 2.5 +/- 1.1 mm vertically and 4.4 +/- 2.1 mm horizontally. On average, the inclination of the acetabular component differed by 7 +/- 2 degrees and anteversion by 9 +/- 3 degrees from the preoperative plans. The mean postoperative leg-length difference was 0.3 +/- 0.1 cm clinically and 0.2 +/- 0.1 cm radiologically. More than 80% of intraoperative difficulties were anticipated. Preoperative planning is of significant value for the successful performance of THR.

Entities:  

Mesh:

Year:  1998        PMID: 9619923     DOI: 10.1302/0301-620x.80b3.7764

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  67 in total

1.  Periprosthetic modelling of femoral component fit using computed tomography data for total hip arthroplasty: a feasibility study.

Authors:  D A Hauser-Kara; D L Bartel
Journal:  Med Biol Eng Comput       Date:  2002-11       Impact factor: 2.602

2.  [Implant position of total hip arthroplasty shafts. Establishment of a new method for comparison between planned and achieved shaft positions].

Authors:  A Fottner; A Steinbrück; E Volkmer; F Haasters; F Mazoochian; V Jansson
Journal:  Orthopade       Date:  2012-07       Impact factor: 1.087

3.  To what degree is digital imaging reliable? Validation of femoral neck shaft angle measurement in the era of picture archiving and communication systems.

Authors:  J D Wilson; W Eardley; S Odak; A Jennings
Journal:  Br J Radiol       Date:  2010-12-15       Impact factor: 3.039

4.  Accuracy of templating the acetabular cup size in Total Hip Replacement using conventional acetate templates on digital radiographs.

Authors:  Vignesh P Krishnamoorthy; Rajamani Perumal; Alfred J Daniel; Pradeep M Poonnoose
Journal:  J Clin Orthop Trauma       Date:  2015-05-11

5.  Does warming up improve surgical outcome in total hip arthroplasty?

Authors:  Asim M Makhdom; AbdulAziz Almaawi; Dylan Tanzer; Michael Tanzer
Journal:  Eur J Orthop Surg Traumatol       Date:  2015-08-20

6.  MyHip: supporting planning and surgical guidance for a better total hip arthroplasty : A pilot study.

Authors:  Jérôme Schmid; Christophe Chênes; Sylvain Chagué; Pierre Hoffmeyer; Panayiotis Christofilopoulos; Massimiliano Bernardoni; Caecilia Charbonnier
Journal:  Int J Comput Assist Radiol Surg       Date:  2015-04-01       Impact factor: 2.924

7.  The role of pre-operative templating in primary total knee replacement.

Authors:  J Arora; S Sharma; M Blyth
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-10-16       Impact factor: 4.342

8.  Potential of P40 plastination for morphometric hip measurements.

Authors:  B Genser-Strobl; M C Sora
Journal:  Surg Radiol Anat       Date:  2005-01-12       Impact factor: 1.246

9.  [Transgluteal mini-incision. Technique and our own results].

Authors:  A Roth; F Layher; R-A Venbrocks
Journal:  Orthopade       Date:  2006-07       Impact factor: 1.087

10.  Acetate templating on digital images is more accurate than computer-based templating for total hip arthroplasty.

Authors:  Robert Petretta; Jason Strelzow; Nicholas E Ohly; Peter Misur; Bassam A Masri
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

View more