Literature DB >> 19629983

Myocardial T2 quantitation in patients with iron overload at 3 Tesla.

Hua Guo1, Wing-Yan Au, Jerry S Cheung, Daniel Kim, Jens H Jensen, Pek-Lan Khong, Queenie Chan, Kevin C Chan, Christina Tosti, Haiying Tang, Truman R Brown, Wynnie W M Lam, Shau-Yin Ha, Gary M Brittenham, Ed X Wu.   

Abstract

PURPOSE: To investigate the feasibility of measuring myocardial T2 at 3 Tesla for assessment of tissue iron in thalassemia major and other iron overloaded patients.
MATERIALS AND METHODS: A single-breathhold electrocardiogram-triggered black-blood multi-echo spin-echo (MESE) sequence with a turbo factor of 2 was implemented at 3 Tesla (T). Myocardial and liver T2 values were measured with three repeated breathholds in 8 normal subjects and 24 patients. Their values, together with the T2 values measured using a breathhold multi-echo gradient-echo sequence, were compared with those at 1.5T in the same patients.
RESULTS: At 3T, myocardial T2 was found to be 39.6 +/- 7.4 ms in normal subjects. In patients, it ranged from 12.9 to 50.1 ms. "T2 and T2(*) [corrected] were observed to correlate in heart (rho = 0.93, P [corrected] < 0.0001) and liver (rho = 0.95, P < 0.0001). Myocardial T2 and T2 at 3T were also highly correlated with the 1.5T measurements. Preliminary results indicated that myocardial T2 quantitation was relatively insensitive to B1 variation, and reproducible with 3.2% intra-exam and 3.8% inter-exam variations.
CONCLUSION: Myocardial T2 quantitation is feasible at 3T. Given the substantially decreased T2 and increased B0 inhomogeneity, the rapid myocardial T2 measurement protocol demonstrated here may present a robust alternative to study cardiac iron overload at 3T. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19629983      PMCID: PMC2946793          DOI: 10.1002/jmri.21851

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  40 in total

1.  Prospects for research in hematologic disorders: sickle cell disease and thalassemia.

Authors:  W C Mentzer; Y W Kan
Journal:  JAMA       Date:  2001-02-07       Impact factor: 56.272

2.  Cardiac susceptibility artifacts arising from the heart-lung interface.

Authors:  M K Atalay; B P Poncelet; H L Kantor; T J Brady; R M Weisskoff
Journal:  Magn Reson Med       Date:  2001-02       Impact factor: 4.668

3.  Human cardiac imaging at 3 T using phased array coils.

Authors:  R Noeske; F Seifert; K H Rhein; H Rinneberg
Journal:  Magn Reson Med       Date:  2000-12       Impact factor: 4.668

4.  Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload.

Authors:  L J Anderson; S Holden; B Davis; E Prescott; C C Charrier; N H Bunce; D N Firmin; B Wonke; J Porter; J M Walker; D J Pennell
Journal:  Eur Heart J       Date:  2001-12       Impact factor: 29.983

Review 5.  Genetic diseases of hemoglobin: diagnostic methods for elucidating beta-thalassemia mutations.

Authors:  S Tuzmen; A N Schechter
Journal:  Blood Rev       Date:  2001-03       Impact factor: 8.250

Review 6.  Noninvasive measurement of iron: report of an NIDDK workshop.

Authors:  Gary M Brittenham; David G Badman
Journal:  Blood       Date:  2002-08-29       Impact factor: 22.113

7.  Double inversion black-blood fast spin-echo imaging of the human heart: a comparison between 1.5T and 3.0T.

Authors:  Robert L Greenman; John E Shirosky; Robert V Mulkern; Neil M Rofsky
Journal:  J Magn Reson Imaging       Date:  2003-06       Impact factor: 4.813

8.  Proton transverse relaxation rate (R2) images of liver tissue; mapping local tissue iron concentrations with MRI [corrected].

Authors:  Paul R Clark; Wanida Chua-Anusorn; Timothy G St Pierre
Journal:  Magn Reson Med       Date:  2003-03       Impact factor: 4.668

9.  Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T.

Authors:  Joelle E Sarlls; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

10.  A single breath-hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload.

Authors:  Mark Westwood; Lisa J Anderson; David N Firmin; Peter D Gatehouse; Clare C Charrier; Beatrix Wonke; Dudley J Pennell
Journal:  J Magn Reson Imaging       Date:  2003-07       Impact factor: 4.813

View more
  28 in total

1.  Comparison of myocardial T1 and T2 values in 3 T with T2* in 1.5 T in patients with iron overload and controls.

Authors:  Gabriel C Camargo; Tamara Rothstein; Flavia P Junqueira; Elsa Fernandes; Andreas Greiser; Ralph Strecker; Viviani Pessoa; Ronaldo S L Lima; Ilan Gottlieb
Journal:  Int J Hematol       Date:  2016-02-12       Impact factor: 2.490

2.  Simultaneous pH-sensitive and oxygen-sensitive MRI of human gliomas at 3 T using multi-echo amine proton chemical exchange saturation transfer spin-and-gradient echo echo-planar imaging (CEST-SAGE-EPI).

Authors:  Robert J Harris; Jingwen Yao; Ararat Chakhoyan; Catalina Raymond; Kevin Leu; Linda M Liau; Phioanh L Nghiemphu; Albert Lai; Noriko Salamon; Whitney B Pope; Timothy F Cloughesy; Benjamin M Ellingson
Journal:  Magn Reson Med       Date:  2018-04-06       Impact factor: 4.668

Review 3.  Cardiac magnetic resonance imaging for the investigation of cardiovascular disorders. Part 2: emerging applications.

Authors:  Ajit H Goenka; Hui Wang; Scott D Flamm
Journal:  Tex Heart Inst J       Date:  2014-04-01

4.  Free-breathing, motion-corrected, highly efficient whole heart T2 mapping at 3T with hybrid radial-cartesian trajectory.

Authors:  Hsin-Jung Yang; Behzad Sharif; Jianing Pang; Avinash Kali; Xiaoming Bi; Ivan Cokic; Debiao Li; Rohan Dharmakumar
Journal:  Magn Reson Med       Date:  2015-03-06       Impact factor: 4.668

5.  Optimizing MR Scan Design for Model-Based ${T}_{1}$ , ${T}_{2}$ Estimation From Steady-State Sequences.

Authors:  Gopal Nataraj; Jon-Fredrik Nielsen; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2016-10-04       Impact factor: 10.048

6.  Accelerated cardiac T2 mapping using breath-hold multiecho fast spin-echo pulse sequence with k-t FOCUSS.

Authors:  Li Feng; Ricardo Otazo; Hong Jung; Jens H Jensen; Jong C Ye; Daniel K Sodickson; Daniel Kim
Journal:  Magn Reson Med       Date:  2011-02-28       Impact factor: 4.668

7.  Rapid T2 mapping of mouse heart using the carr-purcell-meiboom-gill sequence and compressed sensing reconstruction.

Authors:  Yong Chen; Wen Li; Kai Jiang; Charlie Y Wang; Xin Yu
Journal:  J Magn Reson Imaging       Date:  2016-02-08       Impact factor: 4.813

8.  Reduced transverse relaxation rate (RR2) for improved sensitivity in monitoring myocardial iron in thalassemia.

Authors:  Jerry S Cheung; Wing-Yan Au; Shau-Yin Ha; Daniel Kim; Jens H Jensen; Iris Y Zhou; Matthew M Cheung; Yin Wu; Hua Guo; Pek-Lan Khong; Truman R Brown; Gary M Brittenham; Ed X Wu
Journal:  J Magn Reson Imaging       Date:  2011-06       Impact factor: 4.813

9.  Simultaneous measurement of T2 and apparent diffusion coefficient (T2 +ADC) in the heart with motion-compensated spin echo diffusion-weighted imaging.

Authors:  Eric Aliotta; Kévin Moulin; Zhaohuan Zhang; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2017-05-17       Impact factor: 4.668

10.  Relaxivity-iron calibration in hepatic iron overload: Predictions of a Monte Carlo model.

Authors:  Nilesh R Ghugre; Eamon K Doyle; Pippa Storey; John C Wood
Journal:  Magn Reson Med       Date:  2014-09-19       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.