Literature DB >> 8809690

Retention force changes in implant-supported titanium telescope crowns over long-term use in vitro.

C H Besimo1, G Graber, M Flühler.   

Abstract

Titanium is used to fabricate spherical and bar attachments for overdentures on osseointegrated implants. This in vitro study investigated the long-term effects of commercially pure titanium on the retention force of telescope crowns with conical interface. Combinations of various materials for the inner and outer crowns were tested. Telescope crowns of pure titanium showed retention force characteristics comparable to telescope crowns fabricated conventionally in a precious alloy.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8809690     DOI: 10.1111/j.1365-2842.1996.tb00866.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  10 in total

1.  Parameters affecting retentive force of electroformed double-crown systems.

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; Michael Naumann
Journal:  Clin Oral Investig       Date:  2009-04-03       Impact factor: 3.573

2.  Wear behavior of different double-crown systems.

Authors:  Jörg Engels; Oliver Schubert; Jan-Frederik Güth; Matthias Hoffmann; Christian Jauernig; Kurt Erdelt; Michael Stimmelmayr; Florian Beuer
Journal:  Clin Oral Investig       Date:  2012-05-10       Impact factor: 3.573

3.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

4.  Retention and surface changes of zirconia primary crowns with secondary crowns of different materials.

Authors:  Işıl Turp; Ergün Bozdağ; Emin Sünbüloğlu; Cem Kahruman; Ibrahim Yusufoğlu; Gülsen Bayraktar
Journal:  Clin Oral Investig       Date:  2014-01-31       Impact factor: 3.573

5.  Retention force of removable partial dentures with different double crowns.

Authors:  Christin Arnold; Jeremias Hey; Jürgen M Setz; Arne F Boeckler; Ramona Schweyen
Journal:  Clin Oral Investig       Date:  2017-11-03       Impact factor: 3.573

Review 6.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

7.  Retention Load Values of Telescopic Crowns Made of Y-TZP and CoCr with Y-TZP Secondary Crowns: Impact of Different Taper Angles.

Authors:  Susanne Merk; Christina Wagner; Veronika Stock; Patrick R Schmidlin; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-05-11       Impact factor: 3.623

8.  Comparison of retention forces with various fabrication methods and materials in double crowns.

Authors:  Melahat Çelik Güven; Meral Tuna; Ergun Bozdağ; Gizem Nur Öztürk; Gulsen Bayraktar
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

9.  Comparison of Retention of Two Different Attachment Systems Used in Implant-Supported Overdentures.

Authors:  S Dhamodaran; Shafath Ahmed; Vidyashree Nandini; Russia Marimuthu; Sethuraman Ramadoss
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13

10.  Comparison of changes in retentive force of three stud attachments for implant overdentures.

Authors:  Su-Min Kim; Jae-Won Choi; Young-Chan Jeon; Chang-Mo Jeong; Mi-Jung Yun; So-Hyoun Lee; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.