| Literature DB >> 36110775 |
S Dhamodaran1, Shafath Ahmed1, Vidyashree Nandini1, Russia Marimuthu1, Sethuraman Ramadoss1.
Abstract
Aim: This study aims to compare the retentive capacity of two attachment systems after manual thermocycling. Settings and Design: In vitro study and Comparative trail. Materials andEntities:
Keywords: Attachment systems; bar and clip attachment system; implant-supported overdenture; locator attachment system; retentive force; thermocycling
Year: 2022 PMID: 36110775 PMCID: PMC9469436 DOI: 10.4103/jpbs.jpbs_733_21
Source DB: PubMed Journal: J Pharm Bioallied Sci ISSN: 0975-7406
Figure 1Prefabricated castable bar and clips
Figure 2Locator attachment system
Figure 3Total number of eight mandibular overdentures (Group 1 = 4 and Group 2 = 4)
Figure 4Warpage of the overdenture after thermocycling
Figure 5Metal sheet suspended from a metal hook in the crosshead of the UTM
Figure 6Retention test performed in the posterior region of the mandibular overdenture with a pair of metal binder clips and paper clips that engage the posterior regions (right and left molar regions) of the overdenture
Mean and cumulative mean retentive forces of the bar and clip attachment system in the anterior and posterior regions
| Group 1 | Anterior region ( | Posterior region ( | Average of anterior and posterior region ( |
|---|---|---|---|
| S1 | 22.90 | 22.15 | 22.53 |
| S2 | 27.14 | 27.80 | 27.47 |
| S3 | 37.21 | 26.77 | 31.99 |
| S4 | 35.48 | 23.50 | 29.49 |
| Mean | 27.87 |
Mean and cumulative mean retentive forces of the locator attachment system in the anterior and posterior regions
| Group 2 | Anterior region ( | Posterior region ( | Average of anterior and posterior region ( |
|---|---|---|---|
| S1 | 17.36 | 24.39 | 20.88 |
| S2 | 24.74 | 17.55 | 21.15 |
| S3 | 22.00 | 11.12 | 16.56 |
| S4 | 19.98 | 13.66 | 16.82 |
| Mean | 18.85 |
Comparison of mean retentive force between bar and clip attachment system and locator attachment system in the anterior region
| Anterior region | Mean±SD | Mann-Whitney test |
|
|---|---|---|---|
| Group 1 | 30.68±6.80 | 1.000 | 0.043 |
| Group 2 | 21.02±3.12 |
SD: Standard deviation
Comparison of mean retentive force between bar and clip attachment system and locator attachment system in the posterior region
| Posterior region | Mean±SD | Mann-Whitney test |
|
|---|---|---|---|
| Group 1 | 25.06±2.67 | 2.000 | 0.083 |
| Group 2 | 16.68±5.78 |
SD: Standard deviation
Comparison of cumulative mean retentive force between bar and clip attachment system and locator attachment system
| Average of anterior and posterior region | Mean±SD | Mann-Whitney test |
|
|---|---|---|---|
| Group 1 | 27.87±4.01 | 0.000 | 0.021 |
| Group 2 | 18.85±2.50 |
SD: Standard deviation
Chart 1Comparison of cumulative mean retentive force between bar and clip attachment system and locator attachment system