Wear behavior of different double-crown systems.

Jörg Engels1, Oliver Schubert, Jan-Frederik Güth, Matthias Hoffmann, Christian Jauernig, Kurt Erdelt, Michael Stimmelmayr, Florian Beuer.   

Abstract

OBJECTIVES: The aim of this study was to evaluate aging effects on the retentive forces (RFs) of different double-crown systems. The effects of abutment height, inner- and outer-crown-material, taper angle, and artificial aging were analyzed.
MATERIAL AND METHODS: Inner (IC) and outer crowns (OC) (240), divided into four groups, 60 specimens each, were manufactured: A: IC = zirconia, OC = electroformed; B: IC = non-precious alloy, OC = electroformed; C: IC = precious alloy, OC = electroformed; D: IC = precious alloy, OC = conventionally cast (control group). Ten specimens each with three different abutment heights and two different tapers were used. Ten thousand separation cycles were performed for each specimen, and the RFs were measured at baseline, 5,000, and 10,000 cycles in the presence of artificial saliva. Data were imported into a statistical software (SPSS, V18) and analyzed by a multivariate ANOVA test. Significance level was set at 5 %.
RESULTS: Group D showed highest RFs (baseline: 4.0 N; 5,000 cycles: 3.9 N; 10,000 cycles: 3.9 N) compared to A, B, and C (baseline: 2.6/3.5/2.6 N; 5,000 cycles: 2.5/3.4/2.5 N, 10,000: 2.5/3.3/2.5 N). RF was dependent on material (p < 0.001). The RF of groups A, B, and C were dependent on abutment height (p < 0.001), taper angle (p < 0.001), and artificial aging (p < 0.001). Group D showed no correlation between retentive force and abutment height (p = 0.550).
CONCLUSIONS: Wear caused loss of RF in all evaluated groups. However, the material used exhibited significant influence. Conventionally, cast DCs can provide higher RFs, and electroformed DCs can provide more predictable results. CLINICAL RELEVANCE: In clinical cases with few and short abutment teeth, conventionally cast DCs can rather provide the necessary RF than electroformed DCs.

Mesh:

Substances:

Year:  2012        PMID: 22573245     DOI: 10.1007/s00784-012-0746-9

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  32 in total

1.  Technical failure rates of double crown-retained removable partial dentures.

Authors:  M Behr; E Hofmann; M Rosentritt; R Lang; G Handel
Journal:  Clin Oral Investig       Date:  2000-06       Impact factor: 3.573

Review 2.  Telescopic crown-retained removable partial dentures: review and case report.

Authors:  S M Beschnidt; S Chitmongkolsuk; R Prull
Journal:  Compend Contin Educ Dent       Date:  2001-11

3.  [Galvano-outer telescope by direct technique].

Authors:  G Diedrichs; P Rosenhain
Journal:  Quintessenz       Date:  1991-01

4.  Parameters affecting retentive force of electroformed double-crown systems.

Authors:  Florian Beuer; Daniel Edelhoff; Wolfgang Gernet; Michael Naumann
Journal:  Clin Oral Investig       Date:  2009-04-03       Impact factor: 3.573

Review 5.  Survival rates of teeth, implants, and double crown-retained removable dental prostheses: a systematic literature review.

Authors:  Beatrice Koller; Wael Att; Jorg-Rudolf Strub
Journal:  Int J Prosthodont       Date:  2011 Mar-Apr       Impact factor: 1.681

6.  Telescope dentures.

Authors:  M L Perel
Journal:  J Prosthet Dent       Date:  1973-02       Impact factor: 3.426

7.  [Retention mechanism of telescopic crowns].

Authors:  H Becker
Journal:  Zahnarztl Prax       Date:  1983-07-08

8.  [Conical crowns - a rational telescopic system].

Authors:  K H Korber
Journal:  ZWR       Date:  1983-02

9.  Treatment with double crown-retained removable partial dentures and oral health-related quality of life in middle- and high-aged patients.

Authors:  Anne-Christiane Grossmann; Alexander J Hassel; Oliver Schilling; Franziska Lehmann; Andreas Koob; Peter Rammelsberg
Journal:  Int J Prosthodont       Date:  2007 Nov-Dec       Impact factor: 1.681

10.  Does removable partial denture quality affect individuals' oral health?

Authors:  M Inukai; K Baba; M T John; Y Igarashi
Journal:  J Dent Res       Date:  2008-08       Impact factor: 6.116

View more
  11 in total

1.  Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia--an in vitro study.

Authors:  Julian Groesser; Caroline Sachs; Philipp Heiß; Markus Stadelmann; Kurt Erdelt; Florian Beuer
Journal:  Clin Oral Investig       Date:  2013-08-21       Impact factor: 3.573

2.  Electroplated telescopic retainers with zirconia primary crowns: 3-year results from a randomized clinical trial.

Authors:  Franz Sebastian Schwindling; Franziska Lehmann; Sophia Terebesi; Nicoleta Corcodel; Andreas Zenthöfer; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2017-02-11       Impact factor: 3.573

3.  Randomized trial investigating zirconia electroplated telescopic retainers: quality of life outcomes.

Authors:  Franz Sebastian Schwindling; Ulrich Karl Deisenhofer; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Thomas Stober
Journal:  Clin Oral Investig       Date:  2016-06-09       Impact factor: 3.573

4.  Retention and surface changes of zirconia primary crowns with secondary crowns of different materials.

Authors:  Işıl Turp; Ergün Bozdağ; Emin Sünbüloğlu; Cem Kahruman; Ibrahim Yusufoğlu; Gülsen Bayraktar
Journal:  Clin Oral Investig       Date:  2014-01-31       Impact factor: 3.573

5.  Retention force of removable partial dentures with different double crowns.

Authors:  Christin Arnold; Jeremias Hey; Jürgen M Setz; Arne F Boeckler; Ramona Schweyen
Journal:  Clin Oral Investig       Date:  2017-11-03       Impact factor: 3.573

6.  Electroplated and cast double crown-retained removable dental prostheses: 6-year results from a randomized clinical trial.

Authors:  Thomas Stober; Justo Lorenzo Bermejo; Anne-Christiane Séché; Franziska Lehmann; Peter Rammelsberg; Wolfgang Bömicke
Journal:  Clin Oral Investig       Date:  2014-10-11       Impact factor: 3.573

7.  Retention Load Values of Telescopic Crowns Made of Y-TZP and CoCr with Y-TZP Secondary Crowns: Impact of Different Taper Angles.

Authors:  Susanne Merk; Christina Wagner; Veronika Stock; Patrick R Schmidlin; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-05-11       Impact factor: 3.623

8.  Comparison of retention forces with various fabrication methods and materials in double crowns.

Authors:  Melahat Çelik Güven; Meral Tuna; Ergun Bozdağ; Gizem Nur Öztürk; Gulsen Bayraktar
Journal:  J Adv Prosthodont       Date:  2017-08-16       Impact factor: 1.904

9.  PEEK Primary Crowns with Cobalt-Chromium, Zirconia and Galvanic Secondary Crowns with Different Tapers-A Comparison of Retention Forces.

Authors:  Veronika Stock; Patrick R Schmidlin; Susanne Merk; Christina Wagner; Malgorzata Roos; Marlis Eichberger; Bogna Stawarczyk
Journal:  Materials (Basel)       Date:  2016-03-10       Impact factor: 3.623

10.  Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns.

Authors:  Sven Rinke; Ralf Buergers; Dirk Ziebolz; Matthias Roediger
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.