| Literature DB >> 28773477 |
Susanne Merk1, Christina Wagner2, Veronika Stock3, Patrick R Schmidlin4, Malgorzata Roos5, Marlis Eichberger6, Bogna Stawarczyk7.
Abstract
This study aimed to examine and compare the retention load values (RL) of different telescopic crown assemblies (Y-TZP and CoCr primary crowns with electroformed and Y-TZP secondary crowns each) with three different taper angles (0°, 1° and 2°). Thirty Y-TZP primary crowns with electroformed gold copings (Z/G group) and Y-TZP secondary crowns (Z/Z group) and 30 CoCr primary crowns with electroformed gold copings (C/G group) and Y-TZP secondary crowns (C/Z group), each with taper angles of 0°, 1° and 2°, were fabricated, respectively. With the exception of the electroformed gold copings, all specimens were Computer-Aided-Design/Computer-Aided-Manufacturing (CAD/CAM)-milled, then sintered and afterwards manually adapted. In order to stabilize the gold copings, they were fixed in a tertiary structure. The secondary crowns were constructed with a hook, which ensured self-alignment with an upper chain. Afterwards, 20 pull-off test cycles were performed in a universal testing machine under artificial saliva and after weighing the secondary crowns with a 5 kg object for 20 s. Data were analyzed by one-way and two-way Analysis of Variance (ANOVA). C/Z with 1° showed higher (p = 0.009) RL than 0° and 2° tapers. C/G at 1° also showed higher (p = 0.001) RL than at tapers of 0° and 2°. Z/G and C/G at 0° showed lower RL than Z/Z and C/Z (p < 0.001). Primary crowns had no impact on the 0° group. Z/G showed lower RL as compared to C/Z within the 1° group (p = 0.007) and Z/Z in the 2° group (p = 0.006). The primary crown material had no influence on RL. Electroformed copings showed lower RL. Further investigations for 1° as well as for the long-term performance after thermomechanical aging are necessary.Entities:
Keywords: CAD/CAM; Y-TZP; electroforming; retention load; telescopic crowns
Year: 2016 PMID: 28773477 PMCID: PMC5503027 DOI: 10.3390/ma9050354
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Figure 1Treatment groups and combination of the telescopic crown assemblies.
Figure 2Comparison of the sintering procedures: Sinter support structure with Y-TZP secondary crowns (a); and CoCr primary crowns (b).
Figure 3Primary crowns of (a) 0°; and (b) 2° on copper sticks, air brushed with silver conductive lacquer.
Figure 4Electroformed gold coping and CoCr tertiary structure, separate (a); and assembled (b).
Descriptive statistics such as mean with standard deviation (SD), 95% confidence intervals (95% CI) and the non-parametric statistics (minimum/median/maximum). All values are presented in Newton (N).
| Taper Angle | Assemblies | Mean ± SD | 95% CI | Min/Median/Max |
|---|---|---|---|---|
| 0° | C/Z | 17.38 ± 6.98 | (12.2; 22.4) | 7.6/14.9/29.6 |
| Z/Z | 17.63 ± 5.16 | (13.8; 21.4) | 6.4/18.0/24.0 | |
| C/G | 10.38 ± 2.85 | (8.2; 12.5) | 4.8/10.1/14.0 | |
| Z/G | 7.73 ± 5.37 | (3.7; 11.6) | 1.1/7.7/15.0 | |
| 1° | C/Z | 26.44 ± 5.48 | (22.4; 30,4) | 15.9/27.4/34.1 |
| Z/Z | 17.92 ± 6.92 | (12.8; 22.9) | 8.4/16.5/30.0 | |
| C/G | 22.40 ± 8.73 | (16.0; 28.7) | 12.5/20.3/37.0 | |
| Z/G | 14.63 ± 8.26 | (8.6; 20.6) | 3.1/12.1/29.0 | |
| 2° | C/Z | 16.86 ± 8.59 | (10.6; 23.1) | 5.1/18.3/31.4 |
| Z/Z | 22.71 ± 7.31 | (17.3; 28.0) | 16.4/18.4/35.4 | |
| C/G | 14.74 ± 6.05 | (10.3; 19.1) | 4.2/14.3/25.9 | |
| Z/G | 11.35 ± 4.87 | (7.7; 14.9) | 5.3/10.2/20.5 |
C/Z: CoCr primary crown, Y-TZP secondary crown; Z/Z: Y-TZP primary crown, Y-TZP secondary crown; C/G: CoCr primary crown, electroformed gold coping; Z/G: Y-TZP primary crown, electroformed gold coping.