Literature DB >> 8655109

The Orthosystem--a new implant system for orthodontic anchorage in the palate.

H Wehrbein1, J Glatzmaier, U Mundwiller, P Diedrich.   

Abstract

The present report describes the design and first clinical experiences of a newly developed endosseous orthodontic implant anchor system (Orthosystem, Institut Straumann, Waldenburg, Switzerland) for palatal anchorage. The 1-piece fixture made of titanium consists of a screw-type endosseous implant body (sandblasted, acid-etched, diameter 3.3 mm, lengths: 4 and 6 mm), a cylindrical polished transmucosal neck and an abutment. Clamp-caps provide attachment of square commercially available orthodontic wires (0.032 x 0.032 inch, SS) to the abutment (transpalatal bars). In a pilot study 1 fixture (implant body length: 6 mm) was inserted into the midsagittal anterior palatal region in each of 6 adult patients with Angle class II malocclusion (distocclusion 7 to 8 mm, overjet: approximately 9 mm). The treatment plan included extraction of the first maxillary premolars and retraction of the anterior teeth based on maximum anchorage of the posterior teeth without using compliance-dependent anchorage aids (headgear, class II elastics). Due to the design of the fixture only 1 simple surgical procedure was required for insertion (nonsubmerged method, 1-stage surgery). Accordingly the need for surgical exposure of the abutment for connection and wire insertion was eliminated. Thus, inconvenience to patients was reduced to a minimum. The patients are now at varying active treatment stages. The course of treatment of the most advanced case is described. Evaluation of the clinical and radiological findings after 12 months of treatment (3 months implant healing, 9 months active orthodontic treatment which is equal to the implant loading period) revealed no implant mobility/dislocation, favourable peri-implant soft tissue conditions, no marked mesial movement (approximately 0.5 mm) of the implant/transpalatal bar supported posterior teeth, and 8 mm retraction of the anterior teeth. Retrieval of the fixture and post-operative wound healing were uncomplicated. In the treatment of this case, no compliance-dependent extraoral anchorage was used, and the well aligned mandibular dentition was not bonded provide anchorage support (class II elastics).

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8655109     DOI: 10.1007/bf02191878

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  21 in total

1.  Distalization of maxillary first and second molars simultaneously with repelling magnets.

Authors:  L Bondemark; J Kurol
Journal:  Eur J Orthod       Date:  1992-08       Impact factor: 3.075

2.  Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.

Authors:  D Buser; R K Schenk; S Steinemann; J P Fiorellini; C H Fox; H Stich
Journal:  J Biomed Mater Res       Date:  1991-07

3.  Rigid endosseous implant utilized as anchorage to protract molars and close an atrophic extraction site.

Authors:  W E Roberts; K J Marshall; P G Mozsary
Journal:  Angle Orthod       Date:  1990       Impact factor: 2.079

4.  Osseointegrated titanium implants--a new approach in orthodontic treatment.

Authors:  J Odman; U Lekholm; T Jemt; P I Brånemark; B Thilander
Journal:  Eur J Orthod       Date:  1988-05       Impact factor: 3.075

5.  [The development of a resorbable implant system for orthodontic anchorage. The BIOS implant system. Bioresorbable implant anchor for orthodontic systems].

Authors:  J Glatzmaier; H Wehrbein; P Diedrich
Journal:  Fortschr Kieferorthop       Date:  1995-05

6.  Maturational evaluation of ossification of the midpalatal suture.

Authors:  B Revelo; L S Fishman
Journal:  Am J Orthod Dentofacial Orthop       Date:  1994-03       Impact factor: 2.650

7.  Osseointegrated implants as orthodontic anchorage in the treatment of partially edentulous adult patients.

Authors:  J Odman; U Lekholm; T Jemt; B Thilander
Journal:  Eur J Orthod       Date:  1994-06       Impact factor: 3.075

8.  The possibility of skeletal anchorage.

Authors:  T D Creekmore; M K Eklund
Journal:  J Clin Orthod       Date:  1983-04

9.  Studies on the efficacy of implants as orthodontic anchorage.

Authors:  J B Gray; M E Steen; G J King; A E Clark
Journal:  Am J Orthod       Date:  1983-04

Review 10.  Uses of implants in orthodontics.

Authors:  P A Shapiro; V G Kokich
Journal:  Dent Clin North Am       Date:  1988-07
View more
  20 in total

1.  Osteodynamics around orthodontically loaded short maxillary implants. An experimental pilot study.

Authors:  H Wehrbein; M Yildirim; P Diedrich
Journal:  J Orofac Orthop       Date:  1999       Impact factor: 1.938

2.  Assessing bone volume for orthodontic miniplate fixation below the maxillary frontal process.

Authors:  T M Präger; H G Brochhagen; R Mischkowski; P-G Jost-Brinkmann; R Müller-Hartwich
Journal:  J Orofac Orthop       Date:  2014-08-28       Impact factor: 1.938

3.  Accuracy of torque-limiting devices used for mini-implant placement--an in vitro study.

Authors:  Alexander Pauls; Manuel Nienkemper; Dieter Drescher
Journal:  J Orofac Orthop       Date:  2013-03-08       Impact factor: 1.938

4.  Accuracy of torque-limiting devices for mini-implant removal: an in vitro study.

Authors:  A Pauls; M Nienkemper; D Drescher
Journal:  J Orofac Orthop       Date:  2013-05-08       Impact factor: 1.938

5.  Does thread design influence relative bone-to-implant contact rate of palatal implants?

Authors:  Britta A Jung; Martin Kunkel; Peter Göllner; Thomas Liechti; Maximilian Moergel; Robert Noelken; Peter Borbély; Heinrich Wehrbein
Journal:  J Orofac Orthop       Date:  2011-07-10       Impact factor: 1.938

6.  The use of mini-implants in en masse retraction for the treatment of bimaxillary dentoalveolar protrusion.

Authors:  Ali Aljhani; Khalid H Zawawi
Journal:  Saudi Dent J       Date:  2009-12-29

7.  Do sand blasted with large grit and acid etched surface treated mini-implants remain stationary under orthodontic forces?

Authors:  Seong-Hun Kim; Jeong-Ho Choi; Kyu-Rhim Chung; Gerald Nelson
Journal:  Angle Orthod       Date:  2011-08-10       Impact factor: 2.079

8.  Measurement of mini-implant stability using resonance frequency analysis.

Authors:  Manuel Nienkemper; Benedict Wilmes; Agamemnon Panayotidis; Alexander Pauls; Vladimir Golubovic; Frank Schwarz; Dieter Drescher
Journal:  Angle Orthod       Date:  2012-08-29       Impact factor: 2.079

9.  Factors influencing the removal torque of palatal implant used for orthodontic anchorage.

Authors:  Marc Andreas Schätzle; Monika Hersberger-Zurfluh; Raphael Patcas
Journal:  Prog Orthod       Date:  2021-06-07       Impact factor: 2.750

10.  Class II correction by maxillary en masse distalization using a completely customized lingual appliance and a novel mini-screw anchorage concept - preliminary results.

Authors:  Frauke Beyling; Elisabeth Klang; Eva Niehoff; Rainer Schwestka-Polly; Hans-Joachim Helms; Dirk Wiechmann
Journal:  Head Face Med       Date:  2021-06-29       Impact factor: 2.151

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.