Literature DB >> 10605276

Osteodynamics around orthodontically loaded short maxillary implants. An experimental pilot study.

H Wehrbein1, M Yildirim, P Diedrich.   

Abstract

The aim of this study was to investigate experimentally the effect of long-term orthodontic loading on the activity and location of osteodynamic changes around short titanium screw implants. For this purpose 6 maxillary premolars (1P1, 2P2, 3P3) were extracted from each of 2 foxhounds. After a 16-week healing period, 8 implants (4 per dog) were inserted in the edentulous areas. Simultaneously 2 implants (1 per dog) were positioned in the palatal suture. After an 8-week implant healing period the fixtures in the P1/P2 areas (n = 4) and the palate (n = 2) were loaded (test implants) by means of Sentalloy traction springs (approximately 2 N continuous force). The fixtures in the P2/P3 areas served as controls (n = 4). The osteodynamic changes during the force application period (26 weeks) were recorded with bone labeling fluorochromes. Histological evaluation revealed a tendency towards higher remodeling activity within the peri-implant bone (up to 500 microns from the implant surface) of the loaded compared with the unloaded sample. This higher activity was found on both sides facing the loading direction as well as on the opposite sides. Furthermore, within the bone adjacent to the marginal halves of the implants on the loading direction sides, this higher remodeling activity extended more than 1000 microns from the respective implant surfaces. The results suggest that long-term orthodontic loading of short maxillary implants may increase the remodeling activity within the peri-implant bone.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10605276     DOI: 10.1007/bf01388193

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  15 in total

1.  Palatal bone support for orthodontic implant anchorage--a clinical and radiological study.

Authors:  H Wehrbein; B R Merz; P Diedrich
Journal:  Eur J Orthod       Date:  1999-02       Impact factor: 3.075

2.  Rigid endosseous implants for orthodontic and orthopedic anchorage.

Authors:  W E Roberts; F R Helm; K J Marshall; R K Gongloff
Journal:  Angle Orthod       Date:  1989       Impact factor: 2.079

3.  Bone-to-implant contact of orthodontic implants in humans subjected to horizontal loading.

Authors:  H Wehrbein; B R Merz; C H Hämmerle; N P Lang
Journal:  Clin Oral Implants Res       Date:  1998-10       Impact factor: 5.977

4.  The Orthosystem--a new implant system for orthodontic anchorage in the palate.

Authors:  H Wehrbein; J Glatzmaier; U Mundwiller; P Diedrich
Journal:  J Orofac Orthop       Date:  1996-06       Impact factor: 1.938

5.  Osseointegrated titanium implants--a new approach in orthodontic treatment.

Authors:  J Odman; U Lekholm; T Jemt; P I Brånemark; B Thilander
Journal:  Eur J Orthod       Date:  1988-05       Impact factor: 3.075

6.  The biomechanics of force distribution in implant-supported prostheses.

Authors:  L A Weinberg
Journal:  Int J Oral Maxillofac Implants       Date:  1993       Impact factor: 2.804

7.  [Endosseous titanium implants as orthodontic anchoring elements. Experimental studies and clinical application].

Authors:  H Wehrbein
Journal:  Fortschr Kieferorthop       Date:  1994-10

8.  Biomechanical considerations in osseointegrated prostheses.

Authors:  R Skalak
Journal:  J Prosthet Dent       Date:  1983-06       Impact factor: 3.426

Review 9.  Uses of implants in orthodontics.

Authors:  P A Shapiro; V G Kokich
Journal:  Dent Clin North Am       Date:  1988-07

10.  Osseous adaptation to continuous loading of rigid endosseous implants.

Authors:  W E Roberts; R K Smith; Y Zilberman; P G Mozsary; R S Smith
Journal:  Am J Orthod       Date:  1984-08
View more