Literature DB >> 6573144

Studies on the efficacy of implants as orthodontic anchorage.

J B Gray, M E Steen, G J King, A E Clark.   

Abstract

The abilities of two types of small cylindrical endosseous implant to resist movement when loaded with constant forces of orthodontic magnitudes were tested. Pairs of Bioglass-coated implants and pairs of Vitallium implants of the same size were implanted into the femurs of twelve rabbits. After a 28-day healing period, these implants were loaded with forces of 60 grams, 120 grams, and 180 grams. Analysis of implant movement after 28 days revealed that no statistically significant movement occurred at any of the three force levels for either type of implant. Histologic evaluation revealed a connective tissue encapsulation with the Vitallium implant and an implant-bone bond with the Bioglass implant. No histologic evidence of implant movement was observed for either implant type at any force level.

Entities:  

Mesh:

Substances:

Year:  1983        PMID: 6573144     DOI: 10.1016/0002-9416(83)90226-9

Source DB:  PubMed          Journal:  Am J Orthod        ISSN: 0002-9416


  8 in total

1.  The Orthosystem--a new implant system for orthodontic anchorage in the palate.

Authors:  H Wehrbein; J Glatzmaier; U Mundwiller; P Diedrich
Journal:  J Orofac Orthop       Date:  1996-06       Impact factor: 1.938

2.  [The development of a resorbable implant system for orthodontic anchorage. The BIOS implant system. Bioresorbable implant anchor for orthodontic systems].

Authors:  J Glatzmaier; H Wehrbein; P Diedrich
Journal:  Fortschr Kieferorthop       Date:  1995-05

3.  [Endosseous titanium implants as orthodontic anchoring elements. Experimental studies and clinical application].

Authors:  H Wehrbein
Journal:  Fortschr Kieferorthop       Date:  1994-10

4.  Evaluation of Palatal Bone Thickness and Its Relationship with Palatal Vault Depth for Mini-Implant Insertion Using Cone Beam Computed Tomography Images.

Authors:  Gholinia Faegheh; Negar Khosravifard; Dina Maleki; Sahar Khaje Hosseini
Journal:  Turk J Orthod       Date:  2022-06

5.  Osseointegration of orthodontic micro-screws after immediate and early loading.

Authors:  Linkun Zhang; Zhihe Zhao; Yu Li; Jiapei Wu; Leilei Zheng; Tian Tang
Journal:  Angle Orthod       Date:  2010-03       Impact factor: 2.079

6.  Long-term follow-up of dental single implants under immediate orthodontic load.

Authors:  Lisiane Meira Palagi; Carlos Eduardo Sabrosa; Eveline C B Gava; Tiziano Baccetti; Jose Augusto M Miguel
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

7.  Use of the intraosseous screw for unilateral upper molar distalization and found well balanced occlusion.

Authors:  Ibrahim Erhan Gelgor; Ali Ihya Karaman; Tamer Buyukyilmaz
Journal:  Head Face Med       Date:  2006-11-09       Impact factor: 2.151

8.  Evaluating Stress Distribution Pattern in Periodontal Ligament of Maxillary Incisors during Intrusion Assessed by the Finite Element Method.

Authors:  Parisa Salehi; Alayar Gerami; Amirhosein Najafi; Sepideh Torkan
Journal:  J Dent (Shiraz)       Date:  2015-12
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.