Literature DB >> 21830933

Do sand blasted with large grit and acid etched surface treated mini-implants remain stationary under orthodontic forces?

Seong-Hun Kim1, Jeong-Ho Choi, Kyu-Rhim Chung, Gerald Nelson.   

Abstract

OBJECTIVES: To determine the positional stability of sand blasted, large grit, and acid-etched (SLA) surface-treated mini-implants (C-implants) used as the exclusive source of anchorage during en masse retraction.
MATERIALS AND METHODS: A retrospective clinical investigation was performed comparing pretreatment cone beam computed tomography (CBCT) images with those taken after en masse retraction of the six anterior teeth. Force was applied to 16 C-implants (1.8 mm in diameter, 8.5 mm in length) placed between the upper second premolars and first molars. Three-dimensional superimposition of CBCT data using mutual information was used to evaluate the positional difference of C-implants between preretraction and postretraction CBCT data.
RESULTS: There was no significant difference in mini-implant position between the preretraction and postretraction CBCT evaluation.
CONCLUSIONS: The SLA-coated C-implant provides stationary anchorage as well as stable anchorage during orthodontic tooth movement.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21830933      PMCID: PMC8867945          DOI: 10.2319/032511-212.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  21 in total

1.  Do miniscrews remain stationary under orthodontic forces?

Authors:  Eric J W Liou; Betty C J Pai; James C Y Lin
Journal:  Am J Orthod Dentofacial Orthop       Date:  2004-07       Impact factor: 2.650

2.  The C-orthodontic micro-implant.

Authors:  Kyu-Rhim Chung; Seong-Hun Kim; Yoon-Ah Kook
Journal:  J Clin Orthod       Date:  2004-09

3.  A new method for superimposition of CBCT volumes.

Authors:  Jeong-Ho Choi; James Mah
Journal:  J Clin Orthod       Date:  2010-05

4.  Peri-implant bone response to orthodontic loading: Part 1. A histomorphometric study of the effects of implant surface design.

Authors:  Rodrigo Oyonarte; Robert M Pilliar; Douglas Deporter; Donald G Woodside
Journal:  Am J Orthod Dentofacial Orthop       Date:  2005-08       Impact factor: 2.650

5.  Image analysis and superimposition of 3-dimensional cone-beam computed tomography models.

Authors:  Lucia H S Cevidanes; Martin A Styner; William R Proffit
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-05       Impact factor: 2.650

6.  Removal torque values of surface-treated mini-implants after loading.

Authors:  Seong-Hun Kim; Jae-Hee Cho; Kyu-Rhim Chung; Yoon-Ah Kook; Gerald Nelson
Journal:  Am J Orthod Dentofacial Orthop       Date:  2008-07       Impact factor: 2.650

7.  Analysis of temporary skeletal anchorage devices used for en-masse retraction: a preliminary study.

Authors:  Seong-Hun Kim; Young-Suk Hwang; Andre Ferreira; Kyu-Rhim Chung
Journal:  Am J Orthod Dentofacial Orthop       Date:  2009-08       Impact factor: 2.650

8.  The Orthosystem--a new implant system for orthodontic anchorage in the palate.

Authors:  H Wehrbein; J Glatzmaier; U Mundwiller; P Diedrich
Journal:  J Orofac Orthop       Date:  1996-06       Impact factor: 1.938

9.  Multimodality image registration by maximization of mutual information.

Authors:  F Maes; A Collignon; D Vandermeulen; G Marchal; P Suetens
Journal:  IEEE Trans Med Imaging       Date:  1997-04       Impact factor: 10.048

10.  Resistance to immediate orthodontic loading of surface-treated mini-implants.

Authors:  Sung-Seo Mo; Seong-Hun Kim; Yoon-Ah Kook; Do-Min Jeong; Kyu-Rhim Chung; Gerald Nelson
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

View more
  1 in total

1.  Control of anterior segment using an antero-posterior lingual sliding retraction system: a preliminary cone-beam CT study.

Authors:  Min Hwang; Hyo-Won Ahn; Soon-Yong Kwon; Jeong-Ho Choi; Seong-Hun Kim; Gerald Nelson
Journal:  Prog Orthod       Date:  2018-01-15       Impact factor: 2.750

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.