Literature DB >> 8062859

Osseointegrated implants as orthodontic anchorage in the treatment of partially edentulous adult patients.

J Odman1, U Lekholm, T Jemt, B Thilander.   

Abstract

In nine partially edentulous adult patients, mean age 47 years (range 17-64 years) 23 osseointegrated implants were used as orthodontic anchorage to perform the following types of orthodontic tooth movements: tipping, torquing, rotation, intrusion, extrusion, and those associated with bodily movements. The total orthodontic treatment period varied between 4 and 33 months (x = 17 months). Pre-operatively, at the start and end of orthodontic treatment, and at the annual controls, clinical as well as biometric and radiographic (panoramic, lateral cephalograms and periapical radiographs) recordings were performed. The osseointegrated anchorage units were used as reference points for measurements of two- and three-dimensional tooth movements with a co-ordinate machine. The 2-D tooth movements varied between 0.2 and 6.2 mm, whereas movements in the third dimension, extrusion and intrusion, ranged from 0.0 to 13.5 mm. The movement in space for the individual tooth was observed to be, as a mean, 3.9 mm (range 0.6-18.7 mm). However, the osseointegrated titanium implants (fixtures) used as orthodontic anchorage remained in position when orthodontically loaded for the various tooth movements. After completion of the orthodontic treatment the fixtures served as abutments for permanent prosthetic constructions.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 8062859     DOI: 10.1093/ejo/16.3.187

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  5 in total

1.  The Orthosystem--a new implant system for orthodontic anchorage in the palate.

Authors:  H Wehrbein; J Glatzmaier; U Mundwiller; P Diedrich
Journal:  J Orofac Orthop       Date:  1996-06       Impact factor: 1.938

2.  Evaluation of the effect of force direction on stationary anchorage success of mini-implant with a lever-arm-shaped upper structure.

Authors:  Ki-Ho Park; Eun-Man Lee; Seung-Il Shin; Seong-Hun Kim; Young-Guk Park; Su-Jung Kim
Journal:  Angle Orthod       Date:  2011-05-26       Impact factor: 2.079

3.  Which anchorage device is the best during retraction of anterior teeth? An overview of systematic reviews.

Authors:  Yassir A Yassir; Sarah A Nabbat; Grant T McIntyre; David R Bearn
Journal:  Korean J Orthod       Date:  2022-05-25       Impact factor: 1.361

4.  Immediate orthodontic load on dental implants: an option for adult treatment.

Authors:  José Augusto Mendes Miguel; Tatiana Ettore do Valle de Sousa Freitas
Journal:  Dental Press J Orthod       Date:  2019 Nov-Dec

5.  Assessing double Acid-etched implants submitted to orthodontic forces and used as prosthetic anchorages in partially edentulous patients.

Authors:  Rugani de Cravero Marta; Ibañez Juan Carlos
Journal:  Open Dent J       Date:  2008-03-08
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.