Literature DB >> 8576333

Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert Aerobic FAN bottles for detection of bloodstream infections.

J K Pohlman1, B A Kirkley, K A Easley, B A Basille, J A Washington.   

Abstract

A total of 7,190 blood culture sets were obtained from adult patients with a suspected bloodstream infection. A 20-ml sample of blood was distributed equally between the aerobic FAN bottle which was monitored in the BacT/Alert system and a Plus Aerobic/F bottle which was monitored in the BACTEC 9240 system. A total of 988 positive cultures were obtained from 483 patients; however, only 453 positive cultures from 173 patients met the criteria for volume ( > or = ml per bottle) and clinical significance on the basis of concurrent case review required for data analysis. There were 25 and 68 false positives from the FAN and Plus Aerobic/F bottles, respectively. There were no statistically significant differences between systems in the number of positive cultures or septic episodes by species; however, the total number of Enterobacteriaceae and Pseudomonas aeruginosa isolates combined was significantly greater in the FAN bottle (P = 0.04). Detection times did not differ significantly between systems for positive cultures; however, episodes of Staphylococcus aureus bacteremia were detected significantly more rapidly from the FAN bottle (P = 0.005). There was no significant difference between systems in the detection of bloodstream infections in patients receiving antibiotics at the time of blood culture.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8576333      PMCID: PMC228594          DOI: 10.1128/jcm.33.11.2856-2858.1995

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  12 in total

1.  Routine evaluation of BACTEC NR-16A and NR-17A media.

Authors:  R J Courcol; A V Durocher; M Roussel-Delvallez; A Fruchart; G R Martin
Journal:  J Clin Microbiol       Date:  1988-09       Impact factor: 5.948

2.  Clinical comparison of isolator and BACTEC 660 resin media for blood culture.

Authors:  M T Kelly; F J Roberts; D Henry; I Geere; J A Smith
Journal:  J Clin Microbiol       Date:  1990-09       Impact factor: 5.948

3.  Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L G Reimer; M L Wilson; S Smith-Elekes; C R Chuard; K L Joho; L B Reller
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

4.  Evaluation of new blood culture processing systems.

Authors:  J A Moody; C E Fasching; C J Shanholtzer; D N Gerding; L R Peterson
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

5.  Detection of bacteremia in patients receiving antimicrobial therapy: an evaluation of the antimicrobial removal device and 16B medium.

Authors:  G V Doern; N M Gantz
Journal:  J Clin Microbiol       Date:  1983-07       Impact factor: 5.948

6.  Is the antimicrobial removal device a cost-effective addition to conventional blood cultures?

Authors:  R Munro; P J Collignon; T C Sorrell; P Tomlinson
Journal:  J Clin Pathol       Date:  1984-03       Impact factor: 3.411

7.  CDC definitions for nosocomial infections, 1988.

Authors:  J S Garner; W R Jarvis; T G Emori; T C Horan; J M Hughes
Journal:  Am J Infect Control       Date:  1988-06       Impact factor: 2.918

8.  Evaluation of the BACTEC antimicrobial removal system for detection of bacteremia.

Authors:  N M McGuire; C A Kauffman; C S Hertz; J M Kovach
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

9.  Detection of bacteremia with the BACTEC 16B resin blood culture medium.

Authors:  P C DeGirolami; K Eichelberger; J Siegel
Journal:  Am J Clin Pathol       Date:  1984-05       Impact factor: 2.493

10.  Multicenter comparison of the high volume (10 ml) NR BACTEC PLUS system and the standard (5 ml) NR BACTEC system.

Authors:  F P Koontz; K K Flint; J K Reynolds; S D Allen
Journal:  Diagn Microbiol Infect Dis       Date:  1991 Mar-Apr       Impact factor: 2.803

View more
  25 in total

1.  Controlled clinical comparison of BACTEC plus anaerobic/F to standard anaerobic/F as the anaerobic companion bottle to plus aerobic/F medium for culturing blood from adults.

Authors:  M L Wilson; S Mirrett; F T Meredith; M P Weinstein; V Scotto; L B Reller
Journal:  J Clin Microbiol       Date:  2001-03       Impact factor: 5.948

Review 2.  Update on detection of bacteremia and fungemia.

Authors:  L G Reimer; M L Wilson; M P Weinstein
Journal:  Clin Microbiol Rev       Date:  1997-07       Impact factor: 26.132

3.  Advantage of combining resin with lytic BACTEC blood culture media.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  J Clin Microbiol       Date:  1997-10       Impact factor: 5.948

4.  Controlled comparative evaluation of BacT/Alert FAN and ESP 80A aerobic media as means for detecting bacteremia and fungemia.

Authors:  G V Doern; A Barton; S Rao
Journal:  J Clin Microbiol       Date:  1998-09       Impact factor: 5.948

5.  Use of simulated blood cultures to compare a specific fungal medium with a standard microorganism medium for yeast detection.

Authors:  H Fricker-Hidalgo; F Chazot; B Lebeau; H Pelloux; P Ambroise-Thomas; R Grillot
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-02       Impact factor: 3.267

6.  Multicenter comparison of BACTEC 9050 and BACTEC 9240 blood culture systems.

Authors:  P R Murray; G E Hollick; R C Jerris; M L Wilson
Journal:  J Clin Microbiol       Date:  1998-06       Impact factor: 5.948

7.  Comparison of BD Bactec Plus blood culture media to VersaTREK Redox blood culture media for detection of bacterial pathogens in simulated adult blood cultures containing therapeutic concentrations of antibiotics.

Authors:  Nancy S Miller; Dagmar Rogan; Beverley L Orr; Dana Whitney
Journal:  J Clin Microbiol       Date:  2011-02-09       Impact factor: 5.948

8.  Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.

Authors:  R Ziegler; I Johnscher; P Martus; D Lenhardt; H M Just
Journal:  J Clin Microbiol       Date:  1998-03       Impact factor: 5.948

9.  Comparison of BacT/Alert FAN medium with BACTEC NR660 Plus 26A medium.

Authors:  J W Snyder; S K Lude
Journal:  J Clin Microbiol       Date:  1996-05       Impact factor: 5.948

10.  Four-day incubation period for blood culture bottles processed with the Difco ESP blood culture system.

Authors:  G V Doern; A B Brueggemann; W M Dunne; S G Jenkins; D C Halstead; J C McLaughlin
Journal:  J Clin Microbiol       Date:  1997-05       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.