Literature DB >> 9620384

Multicenter comparison of BACTEC 9050 and BACTEC 9240 blood culture systems.

P R Murray1, G E Hollick, R C Jerris, M L Wilson.   

Abstract

The overall recovery of organisms and time to detection with the BACTEC 9050 and BACTEC 9240 systems were compared in a multicenter evaluation. In the first phase of the study, a total of 4,383 compliant aerobic (Plus Aerobic/F) blood culture sets were processed. There was no significant difference in the recovery of individual groups of organisms with the two systems, with the exception of Streptococcus pneumoniae which was isolated more frequently with BACTEC 9050. False-positive signals occurred more often with BACTEC 9240 (58 cultures) than with BACTEC 9050 (43 cultures), but false-negative cultures were uncommon with both systems (3 cultures for each system). Time to detection of positive cultures of clinically significant organisms was essentially the same with both instruments. In the second phase of the study, 2,431 compliant anaerobic (Plus Anaerobic/F) blood culture sets were processed. There was no significant difference in the recovery of organisms with BACTEC 9050 compared with BACTEC 9240. Significantly (P < 0.03) more false-positive signals occurred with BACTEC 9240 (15 cultures) than with BACTEC 9050 (4 cultures). Likewise, more false-negative cultures occurred with BACTEC 9240 (11 cultures) than with BACTEC 9050 (8 cultures). Time to detection of positive cultures of clinically significant organisms was essentially the same with both systems with the exception of anaerobes (N = 10), which were recovered earlier (P < 0.01) with BACTEC 9240 (35.0 h) than with BACTEC 9050 (61.4 h).

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9620384      PMCID: PMC104884     

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  Controlled clinical laboratory comparison of BACTEC plus aerobic/F resin medium with BacT/Alert aerobic FAN medium for detection of bacteremia and fungemia.

Authors:  J H Jorgensen; S Mirrett; L C McDonald; P R Murray; M P Weinstein; J Fune; C W Trippy; M Masterson; L B Reller
Journal:  J Clin Microbiol       Date:  1997-01       Impact factor: 5.948

2.  Multicenter clinical evaluation of a continuous monitoring blood culture system using fluorescent-sensor technology (BACTEC 9240).

Authors:  F S Nolte; J M Williams; R C Jerris; J A Morello; C D Leitch; S Matushek; L D Schwabe; F Dorigan; F E Kocka
Journal:  J Clin Microbiol       Date:  1993-03       Impact factor: 5.948

3.  Comparison of BACTEC 9240 and BacT/Alert blood culture systems in an adult hospital.

Authors:  J A Smith; E A Bryce; J H Ngui-Yen; F J Roberts
Journal:  J Clin Microbiol       Date:  1995-07       Impact factor: 5.948

4.  Clinical comparison of BACTEC 9240 plus aerobic/F resin bottles and the isolator aerobic culture system for detection of bloodstream infections.

Authors:  F R Cockerill; G S Reed; J G Hughes; C A Torgerson; E A Vetter; W S Harmsen; J C Dale; G D Roberts; D M Ilstrup; N K Henry
Journal:  J Clin Microbiol       Date:  1997-06       Impact factor: 5.948

5.  Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert Aerobic FAN bottles for detection of bloodstream infections.

Authors:  J K Pohlman; B A Kirkley; K A Easley; B A Basille; J A Washington
Journal:  J Clin Microbiol       Date:  1995-11       Impact factor: 5.948

6.  Controlled clinical comparison of Isolator and BACTEC 9240 Aerobic/F resin bottle for detection of bloodstream infections.

Authors:  J K Pohlman; B A Kirkley; K A Easley; J A Washington
Journal:  J Clin Microbiol       Date:  1995-10       Impact factor: 5.948

  6 in total
  3 in total

1.  MALDI-TOF MS performance compared to direct examination, culture, and 16S rDNA PCR for the rapid diagnosis of bone and joint infections.

Authors:  E Lallemand; G Coiffier; C Arvieux; E Brillet; P Guggenbuhl; A Jolivet-Gougeon
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2016-03-04       Impact factor: 3.267

2.  Comparison of the VersaTREK blood culture system against the Bactec9240 system in patients with suspected bloodstream infections.

Authors:  Andries W Dreyer; Nazir A Ismail; Deliwe Nkosi; Kathy Lindeque; Marliza Matthews; Danie G van Zyl; Anwar A Hoosen
Journal:  Ann Clin Microbiol Antimicrob       Date:  2011-02-05       Impact factor: 3.944

3.  Time to positivity in blood cultures of adults with Streptococcus pneumoniae bacteremia.

Authors:  Galo Peralta; María José Rodríguez-Lera; Jose Carlos Garrido; Luis Ansorena; María Pía Roiz
Journal:  BMC Infect Dis       Date:  2006-04-27       Impact factor: 3.090

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.