Literature DB >> 8727933

Comparison of BacT/Alert FAN medium with BACTEC NR660 Plus 26A medium.

J W Snyder1, S K Lude.   

Abstract

A total of 6,010 blood culture sets were obtained from adult patients with suspected bacteremia or fungemia. The overall recovery of organisms was equivalent in two systems used, BacT/Alert FAN medium and BACTEC NR660 Plus 26A medium.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 8727933      PMCID: PMC229012          DOI: 10.1128/jcm.34.5.1327-1329.1996

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  7 in total

1.  BacT/Alert: an automated colorimetric microbial detection system.

Authors:  T C Thorpe; M L Wilson; J E Turner; J L DiGuiseppi; M Willert; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

2.  Controlled evaluation of BacT/Alert standard aerobic and FAN aerobic blood culture bottles for detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L G Reimer; M L Wilson; S Smith-Elekes; C R Chuard; K L Joho; L B Reller
Journal:  J Clin Microbiol       Date:  1995-04       Impact factor: 5.948

3.  CDC definitions for nosocomial infections, 1988.

Authors:  J S Garner; W R Jarvis; T G Emori; T C Horan; J M Hughes
Journal:  Am J Infect Control       Date:  1988-06       Impact factor: 2.918

4.  Clinical comparison of the resin-containing BACTEC 26 Plus and the Isolator 10 blood culturing systems.

Authors:  J J Tarrand; C Guillot; M Wenglar; J Jackson; J D Lajeunesse; K V Rolston
Journal:  J Clin Microbiol       Date:  1991-10       Impact factor: 5.948

5.  Controlled comparison of the BacT/Alert and BACTEC 660/730 nonradiometric blood culture systems.

Authors:  M L Wilson; M P Weinstein; L G Reimer; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1992-02       Impact factor: 5.948

6.  Controlled clinical evaluation of BACTEC Plus Aerobic/F and BacT/Alert Aerobic FAN bottles for detection of bloodstream infections.

Authors:  J K Pohlman; B A Kirkley; K A Easley; B A Basille; J A Washington
Journal:  J Clin Microbiol       Date:  1995-11       Impact factor: 5.948

7.  Controlled evaluation of 5 versus 10 milliliters of blood cultured in aerobic BacT/Alert blood culture bottles.

Authors:  M P Weinstein; S Mirrett; M L Wilson; L G Reimer; L B Reller
Journal:  J Clin Microbiol       Date:  1994-09       Impact factor: 5.948

  7 in total
  3 in total

1.  Controlled clinical laboratory comparison of two supplemented aerobic and anaerobic media used in automated blood culture systems to detect bloodstream infections.

Authors:  R Ziegler; I Johnscher; P Martus; D Lenhardt; H M Just
Journal:  J Clin Microbiol       Date:  1998-03       Impact factor: 5.948

2.  Controlled clinical comparison of bioMérieux VITAL and BACTEC NR-660 blood culture systems for detection of bacteremia and fungemia in adults.

Authors:  M L Wilson; S Mirrett; L C McDonald; M P Weinstein; J Fune; L B Reller
Journal:  J Clin Microbiol       Date:  1999-06       Impact factor: 5.948

3.  Comparison of the BacT/Alert FAN aerobic and the Difco ESP 80A aerobic bottles for pediatric blood cultures.

Authors:  P L Welby-Sellenriek; D S Keller; R J Ferrett; G A Storch
Journal:  J Clin Microbiol       Date:  1997-05       Impact factor: 5.948

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.