X-ray imaging using amorphous selenium: feasibility of a flat panel self-scanned detector for digital radiology.

W Zhao1, J A Rowlands.   

Abstract

We investigate a concept for making a large area, flat-panel detector for digital radiology. It employs an x-ray sensitive photoconductor to convert incident x-radiation to a charge image which is then electronically read out with a large area integrated circuit. The large area integrated circuit, also called an active matrix, consists of a two-dimensional array of thin film transistors (TFTs). The potential advantages of the flat-panel detector for digital radiography include: instantaneous digital radiographs without operator intervention; compact size approaching that of a screen-film cassette and thus compatibility with existing x-ray equipment; high quantum efficiency combined with high resolution. Its potential advantages over the x-ray image intensifier (XRII)/video systems for fluoroscopy include: compactness; geometric accuracy; high resolution, and absence of veiling glare. The feasibility of the detector for digital radiology was investigated using the properties of a particular photoconductor (amorphous selenium) and active matrix array (with cadmium selenide TFTs). The results showed that it can potentially satisfy the detector design requirements for radiography (e.g., chest radiography and mammography). For fluoroscopy, the images can be obtained in real-time but the detector is not quantum noise limited below the mean exposure rate typically used in fluoroscopy. Possible improvements in x-ray sensitivity and noise performance for the application in fluoroscopy are discussed.

Entities:  

Mesh:

Substances:

Year:  1995        PMID: 8551983     DOI: 10.1118/1.597628

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  16 in total

1.  Method for reducing noise in X-ray images by averaging pixels based on the normalized difference with the relevant pixel.

Authors:  Masayuki Nishiki; Kunio Shiraishi; Takuya Sakaguchi; Kyojiro Nambu
Journal:  Radiol Phys Technol       Date:  2008-06-20

2.  Flat detectors and their clinical applications.

Authors:  Martin Spahn
Journal:  Eur Radiol       Date:  2005-04-02       Impact factor: 5.315

3.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

4.  Investigation of the signal behavior at diagnostic energies of prototype, direct detection, active matrix, flat-panel imagers incorporating polycrystalline HgI2.

Authors:  Hong Du; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao; Zhong Su; Jin Yamamoto; Yi Wang
Journal:  Phys Med Biol       Date:  2008-02-14       Impact factor: 3.609

5.  Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Mustafa C Altunbas; Lingyun Chen; Tao Han; Tianpeng Wang
Journal:  Med Phys       Date:  2008-06       Impact factor: 4.071

6.  The optimal optical readout for the x-ray light valve--document scanners.

Authors:  P Oakham; Robert D MacDougall; J A Rowlands
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

7.  Method for automatization of the alignment of a laboratory based x-ray phase contrast edge illumination system.

Authors:  T P Millard; M Endrizzi; K Ignatyev; C K Hagen; P R T Munro; R D Speller; A Olivo
Journal:  Rev Sci Instrum       Date:  2013-08       Impact factor: 1.523

8.  Scintillator avalanche photoconductor with high resolution emitter readout for low dose x-ray imaging: lag.

Authors:  Dan Lia; Wei Zhao; Masakazu Nanba; Norifomi Egami
Journal:  Med Phys       Date:  2009-09       Impact factor: 4.071

Review 9.  How I do it: Cone-beam CT during transarterial chemoembolization for liver cancer.

Authors:  Vania Tacher; Alessandro Radaelli; MingDe Lin; Jean-François Geschwind
Journal:  Radiology       Date:  2015-02       Impact factor: 11.105

10.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.