Literature DB >> 24007068

Method for automatization of the alignment of a laboratory based x-ray phase contrast edge illumination system.

T P Millard1, M Endrizzi, K Ignatyev, C K Hagen, P R T Munro, R D Speller, A Olivo.   

Abstract

Here we present a general alignment algorithm for an edge illumination x-ray phase contrast imaging system, which is used with the laboratory systems developed at UCL. It has the flexibility to be used with all current mask designs, and could also be applied to future synchrotron based systems. The algorithm has proved to be robust experimentally, and can be used for the automatization of future commercial systems through automatic alignment and alignment correction.

Entities:  

Mesh:

Year:  2013        PMID: 24007068      PMCID: PMC7116146          DOI: 10.1063/1.4816827

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  13 in total

1.  An innovative digital imaging set-up allowing a low-dose approach to phase contrast applications in the medical field.

Authors:  A Olivo; F Arfelli; G Cantatore; R Longo; R H Menk; S Pani; M Prest; P Poropat; L Rigon; G Tromba; E Vallazza; E Castelli
Journal:  Med Phys       Date:  2001-08       Impact factor: 4.071

2.  Medical phase contrast x-ray imaging: current status and future prospects.

Authors:  R A Lewis
Journal:  Phys Med Biol       Date:  2004-08-21       Impact factor: 3.609

3.  Phase-sensitive imaging and phase tomography using X-ray interferometers.

Authors:  Atsushi Momose
Journal:  Opt Express       Date:  2003-09-22       Impact factor: 3.894

4.  X-ray phase imaging with a grating interferometer.

Authors:  Timm Weitkamp; Ana Diaz; Christian David; Franz Pfeiffer; Marco Stampanoni; Peter Cloetens; Eric Ziegler
Journal:  Opt Express       Date:  2005-08-08       Impact factor: 3.894

5.  Phase and absorption retrieval using incoherent X-ray sources.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Proc Natl Acad Sci U S A       Date:  2012-08-13       Impact factor: 11.205

6.  The design and application of an in-laboratory diffraction-enhanced x-ray imaging instrument.

Authors:  Ivan Nesch; Daniel P Fogarty; Tochko Tzvetkov; Benjamin Reinhart; A Charles Walus; Gocha Khelashvili; Carol Muehleman; Dean Chapman
Journal:  Rev Sci Instrum       Date:  2009-09       Impact factor: 1.523

7.  Digital radiology using active matrix readout of amorphous selenium: geometrical and effective fill factors.

Authors:  G Pang; W Zhao; J A Rowlands
Journal:  Med Phys       Date:  1998-09       Impact factor: 4.071

8.  A new high-definition microfocal X-ray unit.

Authors:  J C Buckland-Wright
Journal:  Br J Radiol       Date:  1989-03       Impact factor: 3.039

9.  X-ray imaging using amorphous selenium: feasibility of a flat panel self-scanned detector for digital radiology.

Authors:  W Zhao; J A Rowlands
Journal:  Med Phys       Date:  1995-10       Impact factor: 4.071

10.  Design of a novel phase contrast x-ray imaging system for mammography.

Authors:  Peter R T Munro; Konstantin Ignatyev; Robert D Speller; Alessandro Olivo
Journal:  Phys Med Biol       Date:  2010-07-05       Impact factor: 3.609

View more
  5 in total

1.  Feasibility testing of a pre-clinical coded aperture phase contrast imaging configuration using a simple fast Monte Carlo simulator.

Authors:  Anthony Kavanagh; Alessandro Olivo; Robert Speller; Borivoj Vojnovic
Journal:  Biomed Opt Express       Date:  2013-12-04       Impact factor: 3.732

2.  Asymmetric masks for laboratory-based X-ray phase-contrast imaging with edge illumination.

Authors:  Marco Endrizzi; Alberto Astolfo; Fabio A Vittoria; Thomas P Millard; Alessandro Olivo
Journal:  Sci Rep       Date:  2016-05-05       Impact factor: 4.379

Review 3.  Recent advances in edge illumination x-ray phase-contrast tomography.

Authors:  Anna Zamir; Charlotte Hagen; Paul C Diemoz; Marco Endrizzi; Fabio Vittoria; Yujia Chen; Mark A Anastasio; Alessandro Olivo
Journal:  J Med Imaging (Bellingham)       Date:  2017-10-16

4.  Large field of view, fast and low dose multimodal phase-contrast imaging at high x-ray energy.

Authors:  Alberto Astolfo; Marco Endrizzi; Fabio A Vittoria; Paul C Diemoz; Benjamin Price; Ian Haig; Alessandro Olivo
Journal:  Sci Rep       Date:  2017-05-19       Impact factor: 4.379

5.  Direct Conversion X-ray Detector with Micron-Scale Pixel Pitch for Edge-Illumination and Propagation-Based X-ray Phase-Contrast Imaging.

Authors:  Abdollah Pil-Ali; Sahar Adnani; Christopher C Scott; Karim S Karim
Journal:  Sensors (Basel)       Date:  2022-08-07       Impact factor: 3.847

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.