Literature DB >> 18296765

Investigation of the signal behavior at diagnostic energies of prototype, direct detection, active matrix, flat-panel imagers incorporating polycrystalline HgI2.

Hong Du1, Larry E Antonuk, Youcef El-Mohri, Qihua Zhao, Zhong Su, Jin Yamamoto, Yi Wang.   

Abstract

Active matrix, flat-panel x-ray imagers based on a-Si:H thin-film transistors offer many advantages and are widely utilized in medical imaging applications. Unfortunately, the detective quantum efficiency (DQE) of conventional flat-panel imagers incorporating scintillators or a-Se photoconductors is significantly limited by their relatively modest signal-to-noise ratio, particularly in applications involving low x-ray exposures or high spatial resolution. For this reason, polycrystalline HgI2 is of considerable interest by virtue of its low effective work function, high atomic number and the possibility of large-area deposition. In this study, a detailed investigation of the properties of prototype, flat-panel arrays coated with two forms of this high-gain photoconductor are reported. Encouragingly, high x-ray sensitivity, low dark current and spatial resolution close to the theoretical limits were observed from a number of prototypes. In addition, input-quantum-limited DQE performance was measured from one of the prototypes at relatively low exposures. However, high levels of charge trapping, lag and polarization, as well as pixel-to-pixel variations in x-ray sensitivity are of concern. While the results of the current study are promising, further development will be required to realize prototypes exhibiting the characteristics necessary to allow practical implementation of this approach.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18296765      PMCID: PMC2706137          DOI: 10.1088/0031-9155/53/5/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  23 in total

1.  Digital radiology using active matrix readout: amplified pixel detector array for fluoroscopy.

Authors:  N Matsuura; W Zhao; Z Huang; J A Rowlands
Journal:  Med Phys       Date:  1999-05       Impact factor: 4.071

2.  Strategies to improve the signal and noise performance of active matrix, flat-panel imagers for diagnostic x-ray applications.

Authors:  L E Antonuk; K W Jee; Y El-Mohri; M Maolinbay; S Nassif; X Rong; Q Zhao; J H Siewerdsen; R A Street; K S Shah
Journal:  Med Phys       Date:  2000-02       Impact factor: 4.071

3.  Additive noise properties of active matrix flat-panel imagers.

Authors:  M Maolinbay; Y El-Mohri; L E Antonuk; K W Jee; S Nassif; X Rong; Q Zhao
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

4.  System performance of a prototype flat-panel imager operated under mammographic conditions.

Authors:  Kyung-Wook Jee; Larry E Antonuk; Youcef El-Mohri; Qihua Zhao
Journal:  Med Phys       Date:  2003-07       Impact factor: 4.071

5.  Evaluation of the imaging properties of an amorphous selenium-based flat panel detector for digital fluoroscopy.

Authors:  D C Hunt; O Tousignant; J A Rowlands
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

6.  Systematic investigation of the signal properties of polycrystalline HgI2 detectors under mammographic, radiographic, fluoroscopic and radiotherapy irradiation conditions.

Authors:  Zhong Su; Larry E Antonuk; Youcef El-Mohri; Larry Hu; Hong Du; Amit Sawant; Yixin Li; Yi Wang; Jin Yamamoto; Qihua Zhao
Journal:  Phys Med Biol       Date:  2005-06-01       Impact factor: 3.609

7.  Performance of a high fill factor, indirect detection prototype flat-panel imager for mammography.

Authors:  Youcef El-Mohri; Larry E Antonuk; Qihua Zhao; Yi Wang; Yixin Li; Hong Du; Amit Sawant
Journal:  Med Phys       Date:  2007-01       Impact factor: 4.071

8.  X-ray imaging using avalanche multiplication in amorphous selenium: investigation of depth dependent avalanche noise.

Authors:  D C Hunt; Kenkichi Tanioka; J A Rowlands
Journal:  Med Phys       Date:  2007-03       Impact factor: 4.071

9.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

10.  A spatial-frequency dependent quantum accounting diagram and detective quantum efficiency model of signal and noise propagation in cascaded imaging systems.

Authors:  I A Cunningham; M S Westmore; A Fenster
Journal:  Med Phys       Date:  1994-03       Impact factor: 4.071

View more
  8 in total

1.  Performance evaluation of polycrystalline HgI2 photoconductors for radiation therapy imaging.

Authors:  Qihua Zhao; Larry E Antonuk; Youcef El-Mohri; Yi Wang; Hong Du; Amit Sawant; Zhong Su; Jin Yamamoto
Journal:  Med Phys       Date:  2010-06       Impact factor: 4.071

2.  An investigation of signal performance enhancements achieved through innovative pixel design across several generations of indirect detection, active matrix, flat-panel arrays.

Authors:  Larry E Antonuk; Qihua Zhao; Youcef El-Mohri; Hong Du; Yi Wang; Robert A Street; Jackson Ho; Richard Weisfield; William Yao
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

3.  Effect of detector lag on CT noise power spectra.

Authors:  Jongduk Baek; Norbert J Pelc
Journal:  Med Phys       Date:  2011-06       Impact factor: 4.071

4.  Theoretical investigation of the noise performance of active pixel imaging arrays based on polycrystalline silicon thin film transistors.

Authors:  Martin Koniczek; Larry E Antonuk; Youcef El-Mohri; Albert K Liang; Qihua Zhao
Journal:  Med Phys       Date:  2017-05-22       Impact factor: 4.071

5.  Development of active matrix flat panel imagers incorporating thin layers of polycrystalline HgI(2) for mammographic x-ray imaging.

Authors:  Hao Jiang; Qihua Zhao; Larry E Antonuk; Youcef El-Mohri; Tapan Gupta
Journal:  Phys Med Biol       Date:  2013-01-14       Impact factor: 3.609

6.  Active pixel imagers incorporating pixel-level amplifiers based on polycrystalline-silicon thin-film transistors.

Authors:  Youcef El-Mohri; Larry E Antonuk; Martin Koniczek; Qihua Zhao; Yixin Li; Robert A Street; Jeng-Ping Lu
Journal:  Med Phys       Date:  2009-07       Impact factor: 4.071

Review 7.  Amorphous and polycrystalline photoconductors for direct conversion flat panel x-ray image sensors.

Authors:  Safa Kasap; Joel B Frey; George Belev; Olivier Tousignant; Habib Mani; Jonathan Greenspan; Luc Laperriere; Oleksandr Bubon; Alla Reznik; Giovanni DeCrescenzo; Karim S Karim; John A Rowlands
Journal:  Sensors (Basel)       Date:  2011-05-09       Impact factor: 3.576

8.  Charge transport mechanism in lead oxide revealed by CELIV technique.

Authors:  O Semeniuk; G Juska; J-O Oelerich; M Wiemer; S D Baranovskii; A Reznik
Journal:  Sci Rep       Date:  2016-09-15       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.