The N-CAT is a newly developed arterial tonometer (TBP) able to determine systolic, diastolic and mean arterial blood pressures continuously and noninvasively. The aim of this study was to evaluate the accuracy and reliability of TBP relative to directly measured invasive blood pressure (IBP) in ten haemodynamically stable postoperative cardiac patients who were in rapid atrial fibrillation (HR > or = 100 bpm). There were differences between TBP and IBP for systolic (-1.7 mmHg) and diastolic (+0.9 mmHg) values but not for the mean arterial blood pressures. The N-CAT was able to follow blood pressure changes closely and demonstrated an average systolic, diastolic and mean bias (+/-SD) of -1.71 +/- 4.6, 0.99 +/- 4.6 and 0.33 +/- 4.2 mmHg, respectively. Although these biases are within the required standards for equivalency for noninvasive blood pressure to invasively determined blood pressure, approximately 20% of the readings were > +/- 10 mmHg while only 5% were > +/- 20 mmHg. Moreover, there were occasional discrepancies of sufficient magnitude and duration which may limit the clinical usefulness of the N-CAT in patients in whom continuous and accurate blood pressure measurement is required.

Entities:  

Mesh:

Year:  1993        PMID: 8485800     DOI: 10.1007/BF03009640

Source DB:  PubMed          Journal:  Can J Anaesth        ISSN: 0832-610X            Impact factor:   5.063


  9 in total

1.  The relative accuracies of two automated noninvasive arterial pressure measurement devices.

Authors:  M S Gorback; T J Quill; M L Lavine
Journal:  J Clin Monit       Date:  1991-01

2.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

3.  Direct blood pressure measurement--dynamic response requirements.

Authors:  R M Gardner
Journal:  Anesthesiology       Date:  1981-03       Impact factor: 7.892

4.  Arterial tonometry: review and analysis.

Authors:  G M Drzewiecki; J Melbin; A Noordergraaf
Journal:  J Biomech       Date:  1983       Impact factor: 2.712

5.  The accuracy of Finapres noninvasive mean arterial pressure measurements in anesthetized patients.

Authors:  N M Gibbs; D R Larach; J A Derr
Journal:  Anesthesiology       Date:  1991-04       Impact factor: 7.892

6.  Continuous noninvasive blood pressure monitoring during thoracic surgery.

Authors:  G I Bardoczky; M Levarlet; E Engelman; A d'Hollander; D Schmartz
Journal:  J Cardiothorac Vasc Anesth       Date:  1992-02       Impact factor: 2.628

7.  Continuous noninvasive finger blood pressure during controlled hypotension. A comparison with intraarterial pressure.

Authors:  R H Epstein; R R Bartkowski; S Huffnagle
Journal:  Anesthesiology       Date:  1991-11       Impact factor: 7.892

8.  Blood pressure measurement by arterial tonometry in controlled hypotension.

Authors:  O Kemmotsu; M Ueda; H Otsuka; T Yamamura; A Okamura; T Ishikawa; D C Winter; J S Eckerle
Journal:  Anesth Analg       Date:  1991-07       Impact factor: 5.108

9.  Comparison of the Finapres and direct arterial pressure monitoring during profound hypotensive anaesthesia.

Authors:  H A Aitken; J G Todd; G N Kenny
Journal:  Br J Anaesth       Date:  1991-07       Impact factor: 9.166

  9 in total
  3 in total

1.  An evaluation of the N-CAT, a new arterial tonometer.

Authors:  N R Searle; J Gauthier; P Sahab
Journal:  Can J Anaesth       Date:  1995-06       Impact factor: 5.063

2.  Clinical evaluation of continuous noninvasive blood pressure monitoring: accuracy and tracking capabilities.

Authors:  C C Young; J B Mark; W White; A DeBree; J S Vender; A Fleming
Journal:  J Clin Monit       Date:  1995-07

Review 3.  Noninvasive continuous hemodynamic monitoring.

Authors:  Jasper Truijen; Johannes J van Lieshout; Wilbert A Wesselink; Berend E Westerhof
Journal:  J Clin Monit Comput       Date:  2012-06-14       Impact factor: 2.502

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.