Clinical evaluation of continuous noninvasive blood pressure monitoring: accuracy and tracking capabilities.

C C Young1, J B Mark, W White, A DeBree, J S Vender, A Fleming.   

Abstract

A continuous, noninvasive device for blood pressure measurement using pulse transit time has been recently introduced. We compared blood pressure measurement determined using this device with simultaneous invasive blood pressure measurements in 35 patients undergoing general endotracheal anesthesia. Data were analyzed for accuracy and tracking ability of the noninvasive technique, and for frequency of unavailable pressure measurements by each method. A total of 25,133 measurements of systolic pressure, diastolic pressure, and mean arterial pressure (MAP) by each method were collected for comparison from 35 patients. Accuracy was expressed by reporting mean bias (invasive pressure minus noninvasive pressure) and limits of agreement between the two measurements. After correction for the offset found when measuring invasive and oscillometric methods of arterial pressure measurement, the mean biases for systolic, diastolic, and mean pressures by the pulse wave method were -0.37 mm Hg, -0.01 mm Hg, and -0.05 mm Hg, respectively (p < 0.001). The limits of agreement were: -29.0 to 28.2 mm Hg, -14.9 to 14.8 mm Hg, and -19.1 to 19.0 mm Hg, respectively (95% confidence intervals). When blood pressure measured invasively changed over time by more than 10 mm Hg, the noninvasive technique accurately tracked the direction of change 67% of the time. During the entire study, 3.2% of the invasive measurements were unavailable and 12.9% of the noninvasive measurements were unavailable. The continuous noninvasive monitoring technique is not of sufficient accuracy to replace direct invasive measurement of arterial blood pressure, owing to relatively wide limits of agreement between the two methods.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1995        PMID: 7561998     DOI: 10.1007/BF01617519

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  26 in total

1.  Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations.

Authors:  G P Gravlee; J K Brockschmidt
Journal:  J Clin Monit       Date:  1990-10

2.  Comparative accuracies of a finger blood pressure monitor and an oscillometric blood pressure monitor.

Authors:  R H Epstein; S Huffnagle; R R Bartkowski
Journal:  J Clin Monit       Date:  1991-04

3.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

4.  National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers.

Authors:  W B White; A S Berson; C Robbins; M J Jamieson; L M Prisant; E Roccella; S G Sheps
Journal:  Hypertension       Date:  1993-04       Impact factor: 10.190

5.  Assessment of the arterial tonometer (N-CAT) for the continuous blood pressure measurement in rapid atrial fibrillation.

Authors:  N R Searle; J Perrault; H Ste-Marie; C Dupont
Journal:  Can J Anaesth       Date:  1993-04       Impact factor: 5.063

Review 6.  Wave reflections and the arterial pulse.

Authors:  M F O'Rourke; T Yaginuma
Journal:  Arch Intern Med       Date:  1984-02

7.  Hazard of automatic noninvasive blood pressure monitoring.

Authors:  A Showman; E K Betts
Journal:  Anesthesiology       Date:  1981-12       Impact factor: 7.892

8.  Complications of vascular catheterization in the critically ill. A prospective study.

Authors:  V K Puri; R W Carlson; J J Bander; M H Weil
Journal:  Crit Care Med       Date:  1980-09       Impact factor: 7.598

9.  Continuous noninvasive blood pressure monitoring during thoracic surgery.

Authors:  G I Bardoczky; M Levarlet; E Engelman; A d'Hollander; D Schmartz
Journal:  J Cardiothorac Vasc Anesth       Date:  1992-02       Impact factor: 2.628

10.  Availability of intraarterial pressure waveforms from catheter-manometer systems during surgery.

Authors:  K H Wesseling; N T Smith
Journal:  J Clin Monit       Date:  1985-01
View more
  8 in total

1.  The relationship between modified pulse wave transit time and cardiovascular changes in isoflurane anesthetized dogs.

Authors:  R Ochiai; J Takeda; H Hosaka; Y Sugo; R Tanaka; T Soma
Journal:  J Clin Monit Comput       Date:  1999-12       Impact factor: 2.502

2.  Pulse transit time: validation of blood pressure measurement under positive airway pressure ventilation.

Authors:  Heidi Schmalgemeier; Thomas Bitter; Stephan Bartsch; Kevin Bullert; Thomas Fischbach; Siegfried Eckert; Dieter Horstkotte; Olaf Oldenburg
Journal:  Sleep Breath       Date:  2011-10-29       Impact factor: 2.816

Review 3.  Pulse transit time by R-wave-gated infrared photoplethysmography: review of the literature and personal experience.

Authors:  Jochanan E Naschitz; Stanislas Bezobchuk; Renata Mussafia-Priselac; Scott Sundick; Daniel Dreyfuss; Igal Khorshidi; Argyro Karidis; Hagit Manor; Mihael Nagar; Elisabeth Rubin Peck; Shannon Peck; Shimon Storch; Itzhak Rosner; Luis Gaitini
Journal:  J Clin Monit Comput       Date:  2004-12       Impact factor: 2.502

4.  Cuffless and Touchless Measurement of Blood Pressure from Ballistocardiogram Based on a Body Weight Scale.

Authors:  Shing-Hong Liu; Bing-Hao Zhang; Wenxi Chen; Chun-Hung Su; Chiun-Li Chin
Journal:  Nutrients       Date:  2022-06-20       Impact factor: 6.706

5.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice.

Authors:  Ramakrishna Mukkamala; Jin-Oh Hahn; Omer T Inan; Lalit K Mestha; Chang-Sei Kim; Hakan Töreyin; Survi Kyal
Journal:  IEEE Trans Biomed Eng       Date:  2015-06-05       Impact factor: 4.538

6.  Validation of blood pressure monitoring using pulse transit time in heart failure patients with Cheyne-Stokes respiration undergoing adaptive servoventilation therapy.

Authors:  Jens Spießhöfer; Jessica Heinrich; Thomas Bitter; Christina Efken; Roman Lehmann; Siegfried Eckert; Dieter Horstkotte; Olaf Oldenburg
Journal:  Sleep Breath       Date:  2013-09-24       Impact factor: 2.816

7.  Ballistocardiogram-Based Approach to Cuffless Blood Pressure Monitoring: Proof of Concept and Potential Challenges.

Authors:  Chang-Sei Kim; Andrew M Carek; Omer T Inan; Ramakrishna Mukkamala; Jin-Oh Hahn
Journal:  IEEE Trans Biomed Eng       Date:  2018-01-24       Impact factor: 4.538

8.  Comparison of noninvasive pulse transit time estimates as markers of blood pressure using invasive pulse transit time measurements as a reference.

Authors:  Mingwu Gao; N Bari Olivier; Ramakrishna Mukkamala
Journal:  Physiol Rep       Date:  2016-05
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.